Display: DxShell timeout. Used by: NP2,QP3 Cause: The operation command to the parts supply unit was not processed within the required time. Remedy: Press READY ON to continue processing, or reboot the machine if this is…
------------------------------
Code: 1107D005
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Auto-clear instruction error!
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D006
Display: PFU calibration data error!
Used by: NP2,QP3
Cause: Failed to acquire PFU calibration data.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D007
Display: MTU calibration data error!
Used by: NP2,QP3
Cause: Failed to acquire MTU calibration data.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D008
Display: Association error!
Used by: NP2,QP3
Cause: An association error occurred during LON communications.
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D009
Display: Association error.
Used by: NP2,QP3
Cause: Failed to acquire association data.
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D00A
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Parts supply unit error!
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D00B
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Failed to normally complete the automatic operation start-up instruction.
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D00C
第 209 页
Display: DxShell timeout.
Used by: NP2,QP3
Cause: The operation command to the parts supply unit was not processed within the required time.
Remedy: Press READY ON to continue processing, or reboot the machine if this is not effective.
------------------------------
Code: 1107D00E
Display: Parts Supply Unit Error
Used by: QP301
Cause: Abnormal software process occurred.
Remedy: Turn off the power and reboot.Contact Fuji if this error occurs frequently.
------------------------------
Code: 1107D00F
Display: Parts Supply Unit Error
Used by: QP301
Cause: No connection with parts supply unit specified in the recipe or communication with the unit fai
led.
Remedy: Connect the parts supply unit and then reperform association processing.
------------------------------
Code: 1107D010
Display: Feeder Error
Used by: QP301
Cause: No feeder in the slot specified in the recipe or no communication with the feeder.
Remedy: Check the feeder positions and reperform association processing if required.
------------------------------
Code: 11081000
Display: EMERGENCY STOP
Used by: MTU3,MTU4,MTU5
Cause: The emergency stop button was pressed at either the machine or the MTU.
Remedy: Release the emergency stop button at either the machine or the MTU.
------------------------------
Code: 11081010
Display: Servo alarm
Used by: MTU3,MTU4,MTU5
Cause: There is a problem with one of the MTU servo axes.
Remedy: Check that no load is applied to the axes.
------------------------------
Code: 11081011
Display: Order alarm
Used by: MTU3,MTU4,MTU5
Cause: A servo axis has exceeded the soft limit set in Proper data or due to a wiring fault etc, the 200 V
power supply is off.
Remedy: If this error occurred during inching, switch on the servo from the MTU panel and using inching
return the axis to a suitable position. In other cases, check that there are no problems with the wiring in
the control box and the wiring to the sensors.
------------------------------
Code: 11081020
Display: Safety door is open
Used by: MTU3,MTU4,MTU5
Cause: The safety door is open.
Remedy: Close the safety door.
------------------------------
第 210 页
Code: 11081031
Display: Part Carrier Cycle alarm
Used by: MTU4
Cause: When the parts supply carrier advances or retracts, the advance end and retract end sensors do
not come on.
Remedy: Check that the position of the sensors has not shifted. Check that there are no anomalies in the
carrier drive motor and actuator. Power may not be supplied to the carrier drive motor controller. In that
case switch on the power.
------------------------------
Code: 11081032
Display: T Axis Cycle alarm
Used by: MTU4
Cause: When the T axis (the tray) moved it did not reach its target position.
Remedy: Check that there are no problems in the T axis servo system and that the various connectors are
correctly connected.
------------------------------
Code: 11081033
Display: X Axis Cycle alarm
Used by: MTU3,MTU4,MTU5
Cause: When the X axis moved it did not reach its target position.
Remedy: Check that there are no problems in the X axis servo system and that the various connectors are
correctly connected.
------------------------------
Code: 11081034
Display: Y Axis Cycle alarm
Used by: MTU3,MTU4,MTU5
Cause: When the Y axis moved it did not reach its target position.
Remedy: Check that there are no problems in the Y axis servo system and that the various connectors are
correctly connected.
------------------------------
Code: 11081035
Display: Z Axis Cycle alarm
Used by: MTU3,MTU4,MTU5
Cause: When the Z axis moved it did not reach its target position.
Remedy: Check that there are no problems in the Z axis servo system and that the various connectors are
correctly connected.
------------------------------
Code: 11081036
Display: Parts Conveyor Cycle alarm
Used by: MTU3,MTU5
Cause: When the parts conveyor axis moved it did not reach its target position.
Remedy: Check that there are no problems in the parts conveyor axis servo system and that the various
connectors are correctly connected.
------------------------------
Code: 11081041
Display: Overtravel: Check X+ Axis
Used by:
Cause: The X axis + overtravel sensor is on, or the software limit has been exceeded.
Remedy: Move the X axis to a point before the overtravel sensor or to a point inside the position set in the
Proper data item max_limit_sx.
------------------------------