FUJI错误代码查询.pdf - 第680页
Used by: QP3,NP2 Cause: Remedy: TY-axis: Specify the origin. ------------------------------ Code: 12068538 Display: TY-axis: It is not possible to specify the origin when the axis is moving. Used by: QP3,NP2 Cause: Remed…
Display: TY-axis servo amp error.
Used by: QP3,NP2
Cause: Servo amp initialization error. No response from servo amp.
Remedy: Cut and resupply the power to the MTU.
------------------------------
Code: 12068530
Display: TY-axis: Overtravel error (software limit) in the +direction.
Used by: QP3,NP2
Cause:
Remedy: Check if the correct data has been input for machine calibration data item Max Limit Position
TY.
------------------------------
Code: 12068531
Display: TY-axis: Overtravel error (software limit) in the -direction
Used by: QP3,NP2
Cause:
Remedy: Check if the correct data has been input for machine calibration data item Min Limit Position
TY.
------------------------------
Code: 12068532
Display: TY-axis: Insufficient servo power.
Used by: QP3,NP2
Cause: A movement command was issued while the power supply to the servos was off.
Remedy: Reset to supply power to the servos.
------------------------------
Code: 12068533
Display: TY-axis: Positioning time-out error.
Used by: QP3,NP2
Cause:
Remedy: Check the servo parameters and the wiring between the servo amps and the servo motors.
------------------------------
Code: 12068534
Display: TY-axis: Positioning travel distance limit error.
Used by: QP3,NP2
Cause:
Remedy: Check the axis traveling distances specified in the production program.
------------------------------
Code: 12068535
Display: TY-axis: File type change error!
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 12068536
Display: TY-axis: Filter constant change error!
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 12068537
Display: TY-axis: Origin specification error!
第 679 页
Used by: QP3,NP2
Cause:
Remedy: TY-axis: Specify the origin.
------------------------------
Code: 12068538
Display: TY-axis: It is not possible to specify the origin when the axis is moving.
Used by: QP3,NP2
Cause:
Remedy: TY-axis: Specify the origin after axis movement has been completed or check the range for the
completion of servo amp positioning.
------------------------------
Code: 12068539
Display: TY-axis: User constant setting error.
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 1206853A
Display: TY-axis: MECHATROLINK servo synchronization error.
Used by: QP3,NP2
Cause:
Remedy: TY-axis: Check the wiring between the controller amps and check for servo amp errors.
------------------------------
Code: 1206853B
Display: TY-axis: MECHATROLINK communication error.
Used by: QP3,NP2
Cause:
Remedy: TY-axis: Check the wiring between the controller amps and check for servo amp errors.
------------------------------
Code: 1206853C
Display: TY-axis: MECHATROLINK servo command time-out error.
Used by: QP3,NP2
Cause:
Remedy: TY-axis: Check the wiring between the controller amps and check for servo amp errors.
------------------------------
Code: 1206853D
Display: TY-axis: Absolute encoder rotation limit error.
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 12068580
Display: TY-axis: Overload warning.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068581
Display: TY-axis: Regeneration overload warning.
Used by: QP3,NP2
Cause: Servo amp error.
第 680 页
Remedy: Reset the servo amp.
------------------------------
Code: 12068582
Display: TY-axis: User constant setting warning.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068583
Display: TY-axis: MECHATROLINK command warning.
Used by: QP3,NP2
Cause:
Remedy: Check if the digital operator is still connected to a servo amplifier.
------------------------------
Code: 12068584
Display: TY-axis: MECHATROLINK communication error warning.
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK communications cable between the MTU controller and servo
amplifier is connected correctly.
------------------------------
Code: 12068585
Display: TY-axis: User constant corruption error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068586
Display: TY-axis: Main circuit detection error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068587
Display: TY-axis: A parameter setting error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068588
Display: TY-axis: Motor/servo capacity mismatch.
Used by: QP3,NP2
Cause:
Remedy: Check that the motor and servo amplifier are connected correctly.
------------------------------
Code: 12068589
Display: TY-axis: Overcurrent error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
第 681 页