Code: 21007946 Display: No entry Machine name. Used by: Cause: The machine name is not registered in Part data. Remedy: Using the editor input the machine name in Part data. ------------------------------ Code: 21007947 …
------------------------------
Code: 2100793E
Display: Parts height regulation over.
Used by:
Cause: The part height exceeds the maximum value (6 mm).
Remedy: Edit the Part data to ensure that the part height does not exceed the maximum value.
------------------------------
Code: 2100793F
Display: Different cartridge name in Input file and Fix apoint file.
Used by:
Cause: An error occurred when assigning fixed feeders.
Remedy: Edit to ensure that the feeder names in the program and the fixed file are the same.
------------------------------
Code: 21007940
Display: Input file name is too long.
Used by:
Cause: The input file name is too long.
Remedy: The input file name should be within 23 characters.
------------------------------
Code: 21007941
Display: Output file name is too long.
Used by:
Cause: The output file name is too long.
Remedy: The output file name should be within 23 characters, including (.o) when the file name is
abbreviated.
------------------------------
Code: 21007942
Display: PST file name is too long.
Used by:
Cause: The permanent set table (PST) file name is too long. The PST file name should be within 23
characters.
Remedy: Set the permanent set table file name to 23 characters or less.
------------------------------
Code: 21007943
Display: Base program file name is too long.
Used by:
Cause: The base program file name is too long.
Remedy: The base program file name should be within 23 characters.
------------------------------
Code: 21007944
Display: Illegal format at MTT file.
Used by:
Cause: The machine type table (MTT) file format is unsuitable.
Remedy: Re-install MTT.CP6.
------------------------------
Code: 21007945
Display: Make not mount sequence.
Used by:
Cause: An error occurred when mounting sequences were being prepared for the output program.
Remedy: Reboot the MCS.
------------------------------
第 1982 页
Code: 21007946
Display: No entry Machine name.
Used by:
Cause: The machine name is not registered in Part data.
Remedy: Using the editor input the machine name in Part data.
------------------------------
Code: 21007947
Display: Illegal format at pairing data file.
Used by:
Cause: The pairing data file format is unsuitable.
Remedy: Re-install the pairing data file.
------------------------------
Code: 21007948
Display: Not get queue position.
Used by:
Cause: The queue position cannot be obtained.
Remedy: Reboot the MCS.
------------------------------
Code: 21007949
Display: Sequence data axis over range.
Used by:
Cause: The sequence coordinates exceed the board size.
Remedy: Edit the input program to ensure that the sequence data coordinates (X, Y) do not exceed the
board size.
------------------------------
Code: 2100794A
Display: Cam table file open error.
Used by:
Cause: The cam table file cannot be opened.
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794B
Display: Cam table file read error.
Used by:
Cause: The cam table file cannot be read.
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794C
Display: Tllegal format at Cam table file.
Used by:
Cause: The cam table file format is unsuitable
Remedy: Re-install the cam table file.
------------------------------
Code: 2100794D
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 2100794E
Display: "There is insufficient space for a feeder in PT file"
第 1983 页
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 2100794F
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21008001
Display: Command Format Error: makenet [-e] +wtlb
Used by:
Cause: An incorrect option is being used.
Remedy: Check the start-up option.
------------------------------
Code: 21008002
Display: Message not found!! No.= ****
Used by:
Cause: Unable to find the necessary message file.
Remedy: Re-install MCS/2E system.
------------------------------
Code: 21008010
Display: Edit file Open error !!
Used by:
Cause: The file created by the editor could not open ethernet_db.
Remedy: Create ethernet_db with the editor.
------------------------------
Code: 21008014
Display: Data base file Open error !!
Used by:
Cause: Unable to open data base files such as hosts, services, etc.
Remedy: Input ':' at the UCI menu and execute "/h0/cmds/attr -w /h0/etc/*" to enable the files to be
read.
------------------------------
Code: 21008020
Display: IP_ADDRESS not digit data !! "disit.digit.digit.digit"
Used by:
Cause: The IP address is incorrect.
Remedy: The IP address must be made up entirely of numerical digits.
------------------------------
Code: 21008021
Display: IP_ADDRESS data rimit over or nothing !! "123.123.123.123"
Used by:
Cause: The IP address is incorrect.
Remedy: Each address group must be between 1 and 3 digits.
------------------------------
Code: 21008022
Display: IP_ADDRESS not 4 data !! "1.2.3.4"