Display: Same as code. Used by: Cause: No leads could be found on the lower side. Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. ------------------------------ Code: 1D…

100%1 / 5282
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43B2??
Display: Same as code.
Used by:
Cause: A lead that should not exist has been found on the lower side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43B3??
Display: Same as code.
Used by:
Cause: A lead that should exist has not been found on the lower side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43B4??
Display: Same as code.
Used by:
Cause: A lead that should not exist has been found on the right side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43B5??
Display: Same as code.
Used by:
Cause: A lead that should exist has not been found on the right side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43B6??
Display: Same as code.
Used by:
Cause: A lead that should not exist has been found on the upper side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43B7??
Display: Same as code.
Used by:
Cause: A lead that should exist has not been found on the upper side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43C0??
Display: Same as code.
Used by:
Cause: No leads could be found on the left side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43C1??
第 1759 页
Display: Same as code.
Used by:
Cause: No leads could be found on the lower side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43C2??
Display: Same as code.
Used by:
Cause: No leads could be found on the right side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43C3??
Display: Same as code.
Used by:
Cause: No leads could be found on the upper side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D43C4??
Display: Same as code.
Used by:
Cause: The left edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D43C5??
Display: Same as code.
Used by:
Cause: The lower edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D43C6??
Display: Same as code.
Used by:
Cause: The right edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D43C7??
Display: Same as code.
Used by:
Cause: The upper edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D43D000
Display: Same as code.
Used by:
Cause: The pickup position error (in the X direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
第 1760 页
Code: 1D43D080
Display: Same as code.
Used by:
Cause: The pickup position error (in the Y direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D43D100
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D43E???
Display: Same as code.
Used by:
Cause: The machine has determined that imaging conditions are not correct.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions. In particular, check for soiling of the nozzle, and make sure that the
CCD level is correct.
------------------------------
Code: 1D43F???
Display: Same as code.
Used by:
Cause: There is a logical error in the processing program. The part cannot be processed due to an
excessive discrepancy between the Part data and the actual values for the part.
Remedy: Check the Part data.
------------------------------
Code: 1D650001
Display:
Used by:
Cause: A range error occurred during vision processing.
Remedy: A range error occurs when a check is performed on a part but the check point is not on the
image. This could be caused by
1) a large part being picked incorrectly, resulting in an incomplete image;
2) an incorrect CCD level setting or broken nozzle, resulting in a bad image;
3) an incorrect value entered in Part data (PDG) so that vision processing could not be done;
4) the Proper values CCD_X and CCD_Y are incorrect, resulting in a bad image;
5) a problem with the vision processing system program. Check the above listed conditions.
------------------------------
Code: 1D650002
Display:
Used by:
Cause: The part could not be found.
Remedy: Check the condition of the part feeding system. Check the CCD level and the nozzle sizes
entered in Proper data. When using a 1608 part S nozzle (1.00 mm) check whether or not the normal size
(1.3mm) is entered. If this is the case and a 1608 part is picked, vision processing might register this as
not a part. If the CCD level is too high, the image will be too dark, and vision processing might register
this as not a part.
------------------------------
Code: 1D650006