(CTL) There are no storage trays or, the unloading elevator is full. Remedy: (APL) Load supply trays or remove the empty trays. (CTL) Load storage trays or remove the finished trays. ------------------------------ Code: …
Remedy: Replace the part that caused the error or increase the "copla_tolerance" item value in part data.
------------------------------
Code: 12070?6E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Within LLL sensor range" (QP2)
Used by: QP242
Cause: Within LLL sensor range.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Increase the value of the part data item, "lead_offset" where the error occured. Alternatively,
change the currently used nozzle to one of smaller diameter.
------------------------------
Code: 12070?6F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Scan_area too large" (QP2)
Used by: QP242,QP201,QP202
Cause: The scan area is too large.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the part does not exceed the maximum size that can be handled by the vision
processing system. If the scan area is set in part data, check that value.
------------------------------
Code: 12070?70
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Scan area is not set" (QP2)
Used by: QP242,QP201,QP202
Cause: The scan area is not set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error does not normally occur.
------------------------------
Code: 12070?71
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Orientation Check Error Check the orientation of the tray" (QP2)
Used by: QP201,QP202
Cause: This is an orientation error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Correct the orientation of the tray and rearrange the packages so that starting from the upper
left hand corner moving downward, the packages fill the tray leaving the bottom right hand corner empty.
------------------------------
Code: 12070?72
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Dummy Parts" (QP2)
Used by: QP201,QP202
Cause: These are dummy parts.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: No remedy is required.
------------------------------
Code: 12070?75
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Tray / Tray Unit Full" (QP2)
Used by: QP201
Cause: (APL) There are no supply trays or, the unloading elevator is full.
(value replacing "?" is module number; error code appears in place of asterisks)
第 734 页
(CTL) There are no storage trays or, the unloading elevator is full.
Remedy: (APL) Load supply trays or remove the empty trays.
(CTL) Load storage trays or remove the finished trays.
------------------------------
Code: 12070?76
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts lost from nozzle" (QP2)
Used by: QP201,QP202
Cause: Parts lost from nozzle.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Place lost parts onto the tray.
------------------------------
Code: 12070?77
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts pick-up error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Failed to pick-up the part.
Remedy: Check the parts supply.
------------------------------
Code: 12070?78
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts placement error" (QP2)
Used by: QP242, QP202,QP203
Cause: Failed to place part.
Remedy: Check to see if the head is holding a part.
------------------------------
Code: 12070?79
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Z-axis, Q-axis outside its movement range." (QP2)
Used by: QP202,QP203
Cause: The Z-axis cannot be moved because the Q-axis is outside its acceptable movement range.
Remedy: Correct the angle of the Q-axis by up to +-15 deg..
------------------------------
Code: 12070?7A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Q-axis, Z-axis outside its movement range." (QP2)
Used by: QP202
Cause: The Q-axis cannot be rotated because the Z-axis is outside its acceptable movement range.
Remedy: Adjust the height of the Z-axis so that it is above the height of the arch motion limit.
------------------------------
Code: 12070?7B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Q-axis as it is outside its rotation range."
Used by: QP202,QP203
Cause: The Q-axis cannot be rotated because it is outside its rotation range.
Remedy: Correct the angle of the Q-axis by up to +-15 deg.
------------------------------
Code: 12070?7C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Specified angle is outside Q-axis rotation range." (QP2)
Used by: QP202,QP203
第 735 页
Cause: The specified angle for the Q-axis is outside the acceptable range.
Remedy: This error does not usually occur.
------------------------------
Code: 12070?7D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mech chuck is holding part. Cannot carry out zero set." (QP2)
Used by: QP202
Cause: Zero setting cannot be carried out because the mechanical chuck is holding a part.
Remedy: Remove the part from the mechanical chuck.
------------------------------
Code: 12070?7E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mech chuck is holding part. Cannot carry out inching" (QP2)
Used by: QP202,QP203
Cause: Inching cannot be carried out because the mechanical chuck is holding a part.
Remedy: Remove the part from the mechanical chuck.
------------------------------
Code: 12070?7F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Failed to check for part." (QP2)
Used by: QP202
Cause: The check for a part on the mechanical chuck failed because only one of the part check sensors is
ON.
Remedy: If there is a part on the chuck,remove it and turn the vacuum off. if there is no part on the
chuck, the parts confirmation sensor may have mistaken part of the machine for a part. Move the placing
head to its retract position. If the same error persists, the part confirmation sensor may require
adjestment.
------------------------------
Code: 12070?80
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No PMC Parameter" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: No PMC parameters exist.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Retransmit the Proper data from the host computer.
------------------------------
Code: 12070?81
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(Servo Not Ready)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: The command could not be executed because the servo was not ready.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: If this error has occurred while another error is in effect, clear the cause of that error then press
the RESET switch and restart the machine. If this error recurs, determine the reason that servo power is
not being supplied to the PMC.
------------------------------
Code: 12070?82