FUJI错误代码查询.pdf - 第1162页
Display: Emergency Stop Used by: Cause: The emergency stop button was pressed (if peripherals were being used, the safety door was open). Remedy: After resetting the emergency stop button (or closing the safety door), pr…
Remedy:
------------------------------
Code: 15040B10
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040B11
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040B12
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040C01
Display: 电路板位置异常 往复臂L
Used by: NXTP
Cause: 搬送处有不明的电路板。
Remedy: 请除去电路板再次放入。
<img src="$LKEY_ERRIMG_MC$/15040C01.PNG">
------------------------------
Code: 15040C02
Display: 电路板位置异常 往复臂R
Used by: NXTP
Cause: 搬送处有不明的电路板。
Remedy: 请除去电路板再次放入。
<img src="$LKEY_ERRIMG_MC$/15040C02.PNG">
------------------------------
Code: 15040C03
Display: 下道工序电路板搬送异常 往复臂L
Used by: NXTP
Cause: 向下道工序的搬运电路板时发生了异常。复臂L搬运轨道的电路板排出到了下道工序,不过,在下道工序不能
进行正常地电路板的搬运,在规定时间(15秒)里从下道工序的电路板来的要求信号没有OFF。
Remedy: 请调整下道工序的搬运轨道宽度以使电路板流动顺畅。
<img src="$LKEY_ERRIMG_MC$/15040C03.PNG">
------------------------------
Code: 15040C04
Display: 下道工序电路板搬运异常 往复臂R
Used by: NXTP
Cause: 向下道工序的搬运电路板时发生了异常。复臂R搬运轨道的电路板排出到了下道工序,不过,在下道工序不能
进行正常地电路板的搬运,在规定时间(15秒)里从下道工序的电路板来的要求信号没有OFF。
Remedy: 请调整下道工序的搬运轨道宽度以使电路板流动顺畅。
<img src="$LKEY_ERRIMG_MC$/15040C04.PNG">
------------------------------
Code: 15050101
第 1161 页
Display: Emergency Stop
Used by:
Cause: The emergency stop button was pressed (if peripherals were being used, the safety door was
open).
Remedy: After resetting the emergency stop button (or closing the safety door), press the reset button.
------------------------------
Code: 15050201
Display: Conveyor Overtravel
Used by:
Cause: The conveyor width overtravel sensor was activated.
Remedy: Inch the conveyor to where the overtravel sensor is off, and press the reset button to cancel this
alarm (on the LCD terminal, press the Start/Over key).
------------------------------
Code: 15050202
Display: Follow-up Error
Used by:
Cause: Follow-up had not yet been finished, and the overtravel sensor was activated. During follow-up,
the board arrival sensor and the borad pass switch were activated (a board is on the conveyor).
Remedy: Inch the conveyor so that the width widens, and press the reset button (on the LCD terminal,
press the Start/Over Key). If there is a board on the conveyor, remove it. Check that the board arrival
sensor is not being activated by something other than a board, and adjust the sensor volume. Then, when
the board arrival sensor is off, press the reset button to cancel the alarm (on the LCD terminal, press the
Start/Over key).
------------------------------
Code: 15050203
Display: Transport Error
Used by:
Cause: The board flowing on the conveyor got caught.
Remedy: Set the board so that it can flow smoothly, and press the reset button to cancel the alarm (on
the LCD terminal, press the Start/Over Key).
------------------------------
Code: 15502100
Display:
Used by:
Cause: There was a main conveyor board check sensor alarm, or the sensor is not adjusted properly.
Remedy: Remove the board by hand. If production has finished, unload the board to the out conveyor. If
it has not finished, put the board back on the in conveyor.
------------------------------
Code: 1601??08
Display: An error occurred for the PFU/MFU cutter.
Machine type: QP3
Used by:
Cause: PFU/MFU tape cutter error. The tape box may not be set correctly.
The feeder slot number is contained in the fifth and sixth digit of the error code (hexadecimal
notation).
Remedy: Check the tape cutter and tape on the PFU/MFU in question.
Check the tape box is set correctly.
------------------------------
Code: 1601000F
Display: STU tray supply time out
Used by: NP2,QP3
第 1162 页
Cause: An STU tray supply time out condition occurred.
Remedy: Check for jammed tray in the STU tray feeder, or for a parts out condition.
------------------------------
Code: 16010012
Display: Stick exchange error
Used by: QP3
Cause: An error occurred while exchanging a feeder stick.
Remedy: After correcting the problem, press the feeder's reset button to clear the error.
------------------------------
Code: 18010001
Display: ERRCODE: 0x18010001
Used by: Handy terminal (QP132)
Cause: Format of transmitted command is incorrect.
Remedy: Restart the machine and the handy terminal.
------------------------------
Code: 18010002
Display: ERRCODE: 0x18010002
Used by: Handy terminal (QP132)
Cause: FIDL was not found.
Remedy: Check to see if the correct feeder was designated. Or, set the correct feeder on the PFU, execute
association processing, then repeat the "verify" request.
------------------------------
Code: 18010003
Display: ERRCODE: 0x18010003
Used by: Handy terminal (QP132)
Cause: Busy status occurred during machine operation.
Remedy: Reexecute later.
------------------------------
Code: 180100F0
Display: ERRCODE: 0x180100F0
Used by: Handy terminal (QP132)
Cause: An undefined command was received. A command not included in the command list (at
specifications) was received.
Remedy: The wrong software version is being used at the machine and handy terminal. Use the correct
software version.
------------------------------
Code: 180100F1
Display: ERRCODE: 0x180100F1
Used by: Handy terminal (QP132)
Cause: The received command had an improper packet length. The received packet length differed from
that defined by the program.
Remedy: The wrong software version is being used at the machine and handy terminal. Use the correct
version.
------------------------------
Code: 180100F2
Display: ERRCODE: 0x180100F2
Used by: Handy terminal (QP132)
Cause: The command does not match the transmission/reception identifier. (For example, the version
command was "MVRM", but the identifier was "R".)
Remedy: Restart the machine and the handy terminal.
------------------------------
第 1163 页