FUJI错误代码查询.pdf - 第428页
Display: Used by: QP242,QP201,QP202,QP203 Cause: Unit number F (VM 1440). Communication internal alarm. Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji. ------------------------------ Code: 1…
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031F61
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Break code character was received.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031F63
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Framing occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031F64
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Parity error occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031F65
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Over-run error occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031F66
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). DCD turned off during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031F72
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F73
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F74
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F75
第 427 页
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F76
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F77
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F78
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F79
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7A
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7B
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7C
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7D
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
第 428 页
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F7E
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F7F
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F80
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F88
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F89
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F8A
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F8B
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12033001
Display: IMAGE SENSOR IS BUSY
IMAGE SENSOR BUSY ERROR
Used by: IP1,IP2
Cause: The image sensor board was previously in operation, so the image could not be taken.
Remedy: Check the image sensor board on the VME rack. Take note of the data displayed.
------------------------------
第 429 页