FUJI错误代码查询.pdf - 第516页
Stage2: X09D D2 PALLET SET CHECK FRONT X09E D2 PALLET SET CHECK REAR Check if there is any foreign matter underneath the pallet, or if the pallet is tilted. ------------------------------ Code: 1205042F Display: Tool mem…
Code: 12050427
Display: Consecutive defective carrier error
Used by: QP301
Cause: The number of consecutive carriers for which an error was recorded has exceeded the specified
limit.
Remedy: Check the condition of the parts on the FOL carrier.
------------------------------
Code: 12050428
Display: Defective package count error
Used by: QP301
Cause: The number of packages for which an error was recorded has exceeded the specified limit.
Remedy: Check the condition of the parts on the FOL carrier.
------------------------------
Code: 12050429
Display: SOOP Data Collection Error!
Used by: QP301
Cause: A communication error occurred between the Machine and amp unit during the collection of
SOOP d ata.
Remedy: Cut the power to the machine and check the RS cable.
------------------------------
Code: 1205042A
Display: Temperature warning.
Used by: QP3
Cause: The heater temperature is outside the suitable range.
Remedy: Wait until the temperature settles.
------------------------------
Code: 1205042B
Display: Heater error.
Used by: QP3
Cause: The heater temperature is not correct. The temperature controller or sensor may be damaged.
Remedy: Cut the power to the machine and check the temperature controller and sensor.
------------------------------
Code: 1205042C
Display: Temperature warning.
Used by: QP3
Cause: Switching to single panel production as the heater temperature is outside the suitable range.
Remedy: Wait until the temperature settles, and then resume operation.
------------------------------
Code: 1205042D
Display: Temperature warning.
Used by: QP3
Cause: Cannot operate as the heater temperature is outside the suitable range.
Remedy: Start operation after the temperature has settled.
------------------------------
Code: 1205042E
Display: Pallet Setting Error
Used by: CP732E,CP742ME,CP742E,CP752E
Cause: Pallet clamping was unsuccessful.
Remedy: Check if the following sensor(s) is ON using I/O.
Stage1: X087 D1 PALLET SET CHECK FRONT
X088 D1 PALLET SET CHECK REAR
第 515 页
Stage2: X09D D2 PALLET SET CHECK FRONT
X09E D2 PALLET SET CHECK REAR
Check if there is any foreign matter underneath the pallet, or if the pallet is tilted.
------------------------------
Code: 1205042F
Display: Tool memory error
Used by: QP3OF
Cause: An unspecified tool exists on the holder.
Remedy: Remove the tool from the holder, or access the tool settings screen at the touch panel to specify
the tool that is attached to the holder.
------------------------------
Code: 12050430
Display: Tool memory error
Used by: QP3OF
Cause: The tool specified at the tool allocation screen is not attached to the holder.
Remedy: Attach the specified tool to the head, or remove the tool setting by opening the tool setttings
screen at the touch panel and changing the tool number to '0'.
------------------------------
Code: 12050431
Display: Tool memory error
Used by: QP3OF
Cause: An unspecified tool exists in a changer socket.
Remedy: Remove the tool if it is attached to the holder as there is the possibility of interference. If a tool
is not attached to the holder, firstly attach a tool to the holder, then open the tool settings screen at the
touch panel and set the holder tool number to '0'.
------------------------------
Code: 12050432
Display: Tool memory error
Used by: QP3OF
Cause: The tool specified at the tool allocation screen is not in the changer socket.
Remedy: Insert the specified tool into the socket, or remove the tool nickname setting at the toolsetttings
screen by changing the tool nickname for the socket to 'Empty'.
------------------------------
Code: 12050433
Display: Tool interference error
Used by: QP3OF
Cause: When performing tool ejection, there is a possibility of interference with another tool.
Remedy: At the touch panel, open the tool settings screen and specify a new position for the tool(s) so that
interference will not occur. Check that the tool nicknames are correct. If all tools are already in a safe
position when this error occurs, check that the tool changer nickname is correct.
------------------------------
Code: 12050434
Display: Tool interference error
Used by: QP3OF
Cause: When performing tool ejection, there is a possibility of interference with the parts camera lighting
unit.
Remedy: At the touch panel, open the tool settings screen and specify a new position for the tool(s) so that
interference will not occur. Check that the tool nicknames are correct. If all tools are already in a safe
position when this error occurs, check that the tool changer nickname is correct.
------------------------------
Code: 12050440
第 516 页
Display: 大型不良元件排出盒已满。
Used by: XP242
Cause: 大型不良元件排出盒已满。
Remedy: 请将大型不良元件排出盒里的元件全部拿掉。
------------------------------
Code: 12050441
Display: 中型不良元件排出盒已满。
Used by: XP242
Cause: 中型不良元件排出盒已满。
Remedy: 请将中型不良元件排出盒里的元件全部拿掉。
------------------------------
Code: 12050442
Display: 送出动作中大型不良元件排出盒脱离。
Used by: XP242
Cause: 在排出动作中大型不良元件排出盒脱离。
Remedy: 请将大型不良元件排出盒装入机器内 。
------------------------------
Code: 12050443
Display: 因大型不良元件排出盒脱离而不能排出不良元件。
Used by: XP242
Cause: 因大型不良元件排出盒脱离而不能排出不良元件。
Remedy: 请将大型不良元件排出盒装入机器内。
------------------------------
Code: 12050444
Display: 大型不良元件排出盒脱离。
Used by: XP242
Cause: 大型不良元件排出盒脱离。
Remedy: 请将大型不良元件排出盒装入机器内。
------------------------------
Code: 12050445
Display: 不能取入影像。
Used by: XP242
Cause: 不能取入影像。
Remedy: 这种错误频繁发生时,有必要更换伺服电路板、影像处理电路板。
------------------------------
Code: 12050446
Display: Wait Ready On
Used by: GPX,NXTP
Cause: 动力源OFF着。
Remedy: 请按下Ready On 开关。
动力源打开。
<img src="$LKEY_ERRIMG_MC$/12050446.PNG">
------------------------------
Code: 12050447
Display: 不能检测出存储吸嘴。请确认是否有折断了的吸嘴存在。
Used by: XP143
Cause: 不能检测出存储吸嘴。
Remedy: 如果在吸嘴存储器内存在有折断了的吸嘴时请除去。
------------------------------
Code: 12050450
Display: 温控泄水槽水满异常
第 517 页