Cause: The lead length is too long (longer than the PDG setting by over 10%). Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that the correct part is being picked. -…
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D05E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D05F???
Display:
Used by:
Cause: There was a logical error in the management probram.
Remedy: Check Part data.
------------------------------
Code: 1D060002
Display:
Used by:
Cause: Parts are not being picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D060004
Display:
Used by:
Cause: The part condition is not correct.
Remedy: Check the image, and check the part size.
------------------------------
Code: 1D060010
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D060011
Display:
Used by:
Cause: An edge without leads cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060012
Display:
Used by:
Cause: The lead length is not long enough (shorter than the PDG setting by over 10%).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060013
Display:
Used by:
第 1305 页
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D060014
Display:
Used by:
Cause: The lead length is not long enough (shorter than the PDG setting by over 10%).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060015
Display:
Used by:
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D060016
Display:
Used by:
Cause: The lead length is not long enough (shorter than the PDG setting by over 10%).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060017
Display:
Used by:
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D060018
Display:
Used by:
Cause: The lead length is not long enough (shorter than the PDG setting by over 10%).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060019
Display:
Used by:
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D06001A
Display:
Used by:
Cause: The shape of the part was strange. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D06001B
Display:
第 1306 页
Used by:
Cause: There are too many leads (set in PDG).
Remedy: Check that the nozzle is not dirty, that there are no foreign particles on the part, and that the
correct part is being analyzed.
------------------------------
Code: 1D06001C
Display:
Used by:
Cause: There are too many leads (compared with the PDG setting).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060020
Display:
Used by:
Cause: There are too many leads (compared with the PDG setting).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060021
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060022
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060023
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060024
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060025
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060026
Display:
Used by:
Cause: The corner lead cannot be found.