Code: 1504022D Display: In-carrier cycle error. Used by: CP-732E, CP-742ME, CP-742E Cause: The in-carrier advance limit sensor failed to switch on. The in-carrier was retracted but the retract limit sensor failed to swit…

100%1 / 5282
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-conveyor mid-stopper ON limit sensor failed to switch on. Although the in-conveyor mid-
stopper was switched off, the OFF limit sensor failed to switch on within the prescribed period of time (3
secs.).
Remedy: If this error occurs even though both the stopper ON and OFF limit sensors switch on within the
prescribed period of time, with the stopper operating correctly, check the operation of the sensors (X0C4,
X0C5).
------------------------------
Code: 15040229
Display: In-conveyor panel set error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Although single-board production is in effect, there are 2 boards on the in-lifter. Alternatively,
during double-board production, the X-direction size of the panel on the in-lifter exceeds the prescribed
size.
Remedy: The in-conveyor panel check revealed a panel problem on the in-conveyor. Verify that the
number of panel s on the in-lifter matches the number of panel s designated by the current production
mode (single-board production). If the panel s are being conveyed properly, verify that the sensors (X0AB,
X0AC, X0AE, X0AF) are operating properly. This error may also occur if there is a mid-stopper problem
which results in the panel s not stopping at the stopper position. The panel interval sensor should be on
when a panel is absent, and off when a panel is present.
------------------------------
Code: 1504022A
Display: 搬运轨道电路板确认传感器异常。
电路板载入异常 IN-MAIN(NXTP)
Used by: CP-732E,CP-742ME,CP-742E,NXTP
Cause: 载入搬运轨道电路板确认传感器异常。 载入侧搬运爪取入载入升降台上的电路板,移动到载入侧搬运爪前进
端完成电路板搬运时,确认载入升降台上的电路板的传感器检测出电路板了。
没有正常地进行从载入搬运轨道向主搬运轨道电路板搬送。(NXTP)
Remedy: 请确认传感器(X0AB,X0AC,X0AD,X0AF)确实动作。 此外,确认电路板间隙传感器在没有电路板时
ON,有的时候OFF。
1.请确认搬运轨道间的电路板载入是否顺畅。(NXTP)
2.请确认IN到达传感器(RX04A)能正常检测电路板。(NXTP)
<img src="$LKEY_ERRIMG_MC$/1504022A.PNG">
------------------------------
Code: 1504022B
Display: In-conveyor panel sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier 1 panel sensor or the in-carrier 2 panel sensor switched on while the in-carrier was
being advanced after a panel was loaded from the in-lifter to the in-carrier. The in-carrier 1 panel sensor
or the in-carrier 2 panel sensor remained on for 0.5 seconds when the XY-table was at its DOWN limit or
loading position with the in-carrier open at its advance limit position.
Remedy: Check to see if the sensors (X0B1, X0B2) are operating properly.
------------------------------
Code: 1504022C
Display: In-lifter cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-lifter UP limit sensor failed to switch on. The in-lifter was lowered but the DOWN limit
sensor failed to switch on within the prescribed time period (3 secs.).
Remedy: Check to see if the in-lifter is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0B5, X0B6) are operating properly.
------------------------------
第 1118 页
Code: 1504022D
Display: In-carrier cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier advance limit sensor failed to switch on. The in-carrier was retracted but the
retract limit sensor failed to switch on within the prescribed time period (8 secs.).
Remedy: Check to see if the in-carrier is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0B3, X0B4) are operating properly.
------------------------------
Code: 1504022E
Display: In-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: After conveying the panel to the advance limit position with the panel being confirmed by the in-
carrier 1 panel sensor and the in-carrier 2 panel sensor, these sensors both switched off before the panel
could be loaded from the in-carrier to the in-lifter, resulting in a panel absent condition on the in-carrier.
In systems with an in-carrier panel present memory, the panel present/absent status on the in-carrier
was checked, but the in-carrier 1 panel sensor and the in-carrier 2 panel sensor could not verify the
presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the in-carrier, use the in-carrier
unclamp command to open the in-carrier. If this error occurs even though panel s are being conveyed
properly, check to see if the sensors (X0B1, X0B2) are operating properly.
------------------------------
Code: 1504022F
Display: In-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: At the in-carrier panel check, the in-carrier 1 panel sensor (X0B1) and the in-carrier 2 panel
sensor (X0B2) both switched on.
Remedy: Check the panel conveyance condition. If this error occurs even though the panel s are being
conveyed properly, check to see if the sensors (X0B1, X0B2) are operating properly.
------------------------------
Code: 15040230
Display: In-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: After panel loading to the in-lifter from the in-carrier began, the in-conveyor 1 panel arrival
sensor or the in-conveyor 2 panel arrival sensor switched from on to off before the in-carrier could be
advanced.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensors (X0AC, X0AE) are operating properly.
------------------------------
Code: 15040231
Display: In-carrier unclamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier unclamp limit sensor input error.
Remedy: Verify that the sensors (X0B7 to X0BA) are operating properly.
------------------------------
Code: 15040232
Display: In-carrier clamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier clamp limit sensor input error.
Remedy: Verify that the sensors (X0BB to X0BE) are operating properly.
------------------------------
Code: 15040233
第 1119 页
Display: In-carrier clamp limit and unclamp limit sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier clamp limit and unclamp limit sensor logic error.
Remedy: Verify that all sensors (X0B7 to X0BE) are operating properly.
------------------------------
Code: 15040234
Display: IN 1 stopper error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The IN 1 stopper ON sensor failed to switch on. Although the IN 1 stopper was switched off, the
OFF limit sensor failed to switch on within the prescribed period of time (3 secs.).
Remedy: Check to see if the stopper is operating smoothly. If operation is smooth, but the error occurs
anyway, check to see if the sensors (X0C1, X0C2) are operating properly.
------------------------------
Code: 15040235
Display: In-conveyor panel set error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: When the in-conveyor 1 stopper was raised, the in-conveyor 1 panel arrival sensor switched from
on to off.
Remedy: Check the panel conveyance condition. The first panel which is already on the in-conveyor may
have been pushed upward out of position.
------------------------------
Code: 15040236
Display: In-conveyor panel conveyance error
Used by: CP-752E
Cause: The panel passed through the in-conveyor panel speed reduction sensor (X0AB) however, it was
not detected by the panel
arrival check sensor (X0AC) within the specified time limit.
Remedy: Check that the in-conveyor panel arrival check sensor is functioning properly and confirm the
panel status.
------------------------------
Code: 15040237
Display: In-conveyor panel conveyance error
Used by: CP-752E
Cause: An attempt was made to transfer the panel from the in-conveyor to the main-conveyor however,
the in-conveyor panel spee
d reduction sensor (X0AB) or the panel arrival check sensor (X0AC) did not deactivate (OFF) within the
specified time limit.
Remedy: Check that the in-conveyor panel speed reduction and panel arrival check sensors are
functioning properly and confirm t
he panel status.
------------------------------
Code: 15040238
Display: In-conveyor Stopper Error
Used by: CP-752E
Cause: One of the following errors has occurred:
The machine output the "lower stopper" signal, however the stopper lower end sensor (X0C2) did not
activate (ON).
oth the in-conveyor stopper upper end sensor (X0C1) and the in-conveyor stopper lower end sensor (X0C2)
did not activate (ON) wi
thin the specified time limit.
Both the in-conveyor stopper upper end sensor (X0C1) and the in-conveyor stopper lower end sensor
第 1120 页