FUJI错误代码查询.pdf - 第693页

Used by: QP3,NP2 Cause: Remedy: Check if the <slot number> for the MPOSIT command exceeds the number of available slots. ------------------------------ Code: 12068C72 Display: MPOSIT <sub-slot> data error! Us…

100%1 / 5282
Code: 12068C30
Display: MCHECK <mode> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <mode> for the MCHECK command falls outside the 0-5 range.
------------------------------
Code: 12068C31
Display: MCHECK <timer> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <timer> for the MCHECK command falls outside the 0-10000 range.
------------------------------
Code: 12068C40
Display: MINCHC <mode> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <mode> for the MINCH command has been set to a value other than 0 or 1.
------------------------------
Code: 12068C50
Display: MIOCNT <request content> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <request content> for the MIOCNT command has been set to a value other than 0 or
1.
------------------------------
Code: 12068C51
Display: MICONT <interval> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <interval> for the MIOCNT command falls outside the 50-10000 range.
------------------------------
Code: 12068C60
Display: MSVCNT <interval> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <interval> for the MSVCNT command falls outside the 50-10000 range.
------------------------------
Code: 12068C61
Display: MSVCNT <Coordinate mode> data error.
Used by: QP3,NP2
Cause:
Remedy: Check whether a value other than 0 or 1 has been set for the MSVCNT <Coordinate mode>.
------------------------------
Code: 12068C70
Display: MPOSIT <operation mode> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <operation mode> for the MPOSIT command falls outside the 0-6 range.
------------------------------
Code: 12068C71
Display: MPOSIT <slot number> data error!
第 692 页
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPOSIT command exceeds the number of available slots.
------------------------------
Code: 12068C72
Display: MPOSIT <sub-slot> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot> for the MPOSIT command has been set to a value other than 1 or 2.
------------------------------
Code: 12068C73
Display: MPOSIT <offset> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <offset> for the MPOSIT command exceeds the travel limits for the TY-axis.
------------------------------
Code: 12068C80
Display: MPRXY1 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY1 command falls outside the 0-2 range.
------------------------------
Code: 12068C81
Display: MPRXY1 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY1 command falls outside the 1-10 range.
------------------------------
Code: 12068C82
Display: MPRXY1 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY1 command falls outside the 1-2 range.
------------------------------
Code: 12068C83
Display: MPRXY1 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY1 command falls outside the 0-1 range.
------------------------------
Code: 12068C84
Display: MPRXY2 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY2 command falls outside the 0-2 range.
------------------------------
Code: 12068C85
Display: MPRXY2 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY2 command falls outside the 11-20 range.
第 693 页
------------------------------
Code: 12068C86
Display: MPRXY2 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY2 command falls outside the 1-2 range.
------------------------------
Code: 12068C87
Display: MPRXY2 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY2 command falls outside the 0-1 range.
------------------------------
Code: 12068C88
Display: Check if the <input method> for the MPRXY3 command falls outside the 0-2 range.
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY3 command falls outside the 0-2 range.
------------------------------
Code: 12068C89
Display: MPRXY3 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY3 command falls outside the 21-30 range.
------------------------------
Code: 12068C8A
Display: MPRXY3 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY3 command falls outside the 1-2 range.
------------------------------
Code: 12068C8B
Display: MPRXY3 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY3 command falls outside the 0-1 range.
------------------------------
Code: 12068C8C
Display: MPRXY4 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY4 command falls outside the 0-2 range.
------------------------------
Code: 12068C8D
Display: MPRXY4 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY4 command falls outside the 31-40 range.
------------------------------
Code: 12068C8E
Display: MPRXY4 <sub-slot number> data error!
第 694 页