Cause: No sequence data exists. Remedy: Correct the sequence data. ------------------------------ Code: 21009021 Display: Output error filename not specified Used by: Cause: The error output destination was not specified…
Display: can't rewrite expand file
Used by:
Cause: The expander cannot write data to a file which already contains expanded data.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 21009019
Display: Expander file create error
Used by:
Cause: The file for the Expander output data could not be created.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 2100901A
Display: specify check file no program
Used by:
Cause: The specified file is not a production program file.
Remedy: Input the correct file name.
------------------------------
Code: 2100901B
Display: specify check file no proper
Used by:
Cause: The specified file is not a Proper Data file.
Remedy: Input the correct file name.
------------------------------
Code: 2100901C
Display: specify check file no status
Used by:
Cause: The specified file is not a Status Data file.
Remedy: Input the correct file name.
------------------------------
Code: 2100901D
Display: '+' option not found
Used by:
Cause: The '+' option was not specified at start-up.
Remedy: If the error occurred during a direct command, check the command option.
------------------------------
Code: 2100901E
Display: over range data of expand program
Used by:
Cause: After the data is expanded, a sequence data X or Y value exceeds the permitted range (-65000 to
65000).
Remedy: Correct the X or Y value in the sequence data.
------------------------------
Code: 2100901F
Display: Block 0 placing sequence present
Used by:
Cause: A placing sequence exists for Block 0.
Remedy: Correct the B data in the sequence. This is a warning message only.
------------------------------
Code: 21009020
Display: Sequence data not found
Used by:
第 1994 页
Cause: No sequence data exists.
Remedy: Correct the sequence data.
------------------------------
Code: 21009021
Display: Output error filename not specified
Used by:
Cause: The error output destination was not specified when a background task was started up.
Remedy: If the error occurred due to a direct command, input the command correctly.
------------------------------
Code: 21009022
Display: Compress filename not found
Used by:
Cause: Compressed file not specified.
Remedy: Specify a file.
------------------------------
Code: 21009023
Display: Compress file on disk not found
Used by:
Cause: The compressed file does not exist.
Remedy: Check the filename.
------------------------------
Code: 21009024
Display: check flag read error
Used by:
Cause: The check flag could not be read.
Remedy: Save and correct the file at the editor.
------------------------------
Code: 21009025
Display: check flag rewrite error
Used by:
Cause: The check flag could not be re-written.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 21009026
Display: compress file info_data set error
Used by:
Cause: Information data could not be written to the compressed file.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 21009027
Display: can't write expand data
Used by:
Cause: The expanded data could not be written.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 21009028
Display: File Descriptor check data read error
Used by:
Cause: Data could not be read from the File Descriptor.
Remedy: Re-execute the function. If the error recurs, re-install the software.
------------------------------
第 1995 页
Code: 21009029
Display: Can't rewrite data check flag
Used by:
Cause: The data check flag could not be re-written.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 2100902A
Display: Can't calculate device quantity and Program_information data
Used by:
Cause: The number of devices used in the expanded data and the information data could not be set.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 2100902B
Display: Syntax error: illegal '-d' option
Used by:
Cause: An illegal "-d" option was specified at start-up.
Remedy: If the error occurred due to a direct command, input the command correctly.
------------------------------
Code: 2100902D
Display: Muti_block count read error
Used by:
Cause: The multi-block data in the program could not be read.
Remedy: Check that the data at the editor is not incorrect. Save and correct the file.
------------------------------
Code: 2100902E
Display: Expanded file copy error
Used by:
Cause: The original program could not be copied to an expander file.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 2100A001
Display: /pipe/transmit_controller open error
Used by:
Cause: The TC pipe could not be opened.
Remedy: Re-boot MCS.
------------------------------
Code: 2100A002
Display: /pipe/transmit prcs open error
Used by:
Cause: The pipe from the TC to the transmit process could not be opened.
Remedy: Re-boot MCS.
------------------------------
Code: 2100A003
Display: qp_open pseudo pipe open error
Used by:
Cause: The queue pipe could not be opened.
Remedy: Re-boot MCS.
------------------------------
Code: 2100A004
Display: /pipe/tci back open error
Used by: