Used by: Cause: The lead pitch is too wide. Remedy: Check the lead pitch and the part supply direction. Lead thickness is critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50…

100%1 / 5282
Code: 1D380001
Display: Same as code.
Used by:
Cause: There is an omission in the Part data.
Remedy: Enter the necessary data.
------------------------------
Code: 1D380003
Display: Same as code.
Used by:
Cause: The camera cannot acquire a part image. The part is too large.
Remedy: Check the camera, video processing board, cable, and focus. Check the part. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D380004
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Inspect the part for missing leads, and check lead width. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D380005
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D380006
Display: Same as code.
Used by:
Cause: Only one lead could be found.
Remedy: Inspect the part for missing leads, and check the part supply direction. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D380007
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D380008
Display: Same as code.
第 1693 页
Used by:
Cause: The lead pitch is too wide.
Remedy: Check the lead pitch and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D380009
Display: Same as code.
Used by:
Cause: A sufficient number of leads could not be found.
Remedy: Check the lead quantity and the part supply direction. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D38000B
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D38000C
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D38000D
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D38000E
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D38000F
Display: Same as code.
Used by:
Cause: Processing error.
第 1694 页
Remedy: Check the part's shape. Check for a missing part.
------------------------------
Code: 1D380010
Display: Same as code.
Used by:
Cause: The lead pitch is incorrect.
Remedy: Check the lead pitch and the lead quantity. Lead thickness is critical to lead detection. Leads
can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part data. A
variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D380011
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the part supply direction.
------------------------------
Code: 1D390001
Display: Same as code.
Used by:
Cause: There is an omission in the Part data.
Remedy: Enter the necessary data.
------------------------------
Code: 1D390003
Display: Same as code.
Used by:
Cause: The camera cannot acquire a part image. The part is too large.
Remedy: Check the camera, video processing board, cable, and focus. Check the part.
------------------------------
Code: 1D390004
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Inspect the part for missing leads, and check lead width. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D390005
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D390006
Display: Same as code.
Used by:
Cause: Only one lead could be found.
Remedy: Inspect the part for missing leads, and check the part supply direction. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the