FUJI错误代码查询.pdf - 第1148页

------------------------------ Code: 1504060E Display: OUT INTERLOCK SS NOT ORG POS LD_ERR 1504060E Used by: Cause: The SS-axis is not at its origin position. Remedy: Move the SS-axis to its origin position. ------------…

100%1 / 5282
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040608
Display: )NOT FIT PCB DATA
Loader error: 15040608
Used by: QP132
Cause: The board unload position calculations could not be made.
Remedy: If there is a board remaining in the machine, then unload the board and restart.
------------------------------
Code: 15040609
Display: OUT INTERLOCK PLT PASSED1 ON
LD_ERR 15040609
Used by:
Cause: The production conveyor pallet popped up onto the unloader.
Remedy: Return the pallet to the production conveyor or slide the pallet onto the unloader. Check the
operation of the pallet unload pass-through-check 1 sensor.
------------------------------
Code: 1504060A
Display: OUT INTERLOCK PLT PASSED2 ON
LD_ERR 15040609
Used by:
Cause: The pallet on the return conveyor popped off the unloader.
Remedy: Slide the pallet onto the return conveyor or return the pallet to the unloader. Check the
operation of the pallet unload pass-through-check 2 sensor.
------------------------------
Code: 1504060B
Display: OUT INTERLOCK PCB CLAMP ON
LD_ERR 1504060B
Used by:
Cause: This error is the result of the board clamp on the out-conveyor side being in the clamped status.
Remedy: Unclamp the board clamp on the out-conveyor side. Check the operation of the exit board
pusher clamp limit sensor.
------------------------------
Code: 1504060C
Display: OUT INTERLOCK PCB PASSED ON
Loader error: 1504060C
Used by: QP132
Cause: The board on the out-conveyor popped off the unloader.
Remedy: Return the board to the unloader or slide it onto the out-conveyor. Check the operation of the
out-conveyor board pass-through-check sensor.
------------------------------
Code: 1504060D
Display: OUT INTERLOCK HOOK PULLED OFF
LD_ERR 1504060D
Used by:
Cause: The PO-axis board hooks was not in the released status.
Remedy: Release the PO-axis board hooks. Check the operation of the PO-axis hook release status
sensor.
第 1147 页
------------------------------
Code: 1504060E
Display: OUT INTERLOCK SS NOT ORG POS
LD_ERR 1504060E
Used by:
Cause: The SS-axis is not at its origin position.
Remedy: Move the SS-axis to its origin position.
------------------------------
Code: 15040610
Display: SHUTTER OPEN TIMEUP
Loader error: 15040610
Used by: QP132
Cause: The opening operation of the unload shutter was not completed within the set amount of time.
Remedy: Check the unload shutter operation and the operation of the shutter open check sensor.
------------------------------
Code: 15040611
Display: SHUTTER CLOSE TIMEUP
Loader error: 15040611
Used by: QP132
Cause: The closing operation of the unload shutter was not completed within the set amount of time.
Remedy: Check the unload shutter operation and the operation of the shutter close check sensor.
------------------------------
Code: 15040620
Display: PALLET ON UNLOADER
Loader error: 15040620
Used by: QP132
Cause: Unloader conveyor pallet arrival sensor 1 was on when the machine attempted indexing during
initiation or pallet switchover.
Remedy: The ID reader at the OUT end is misreading, or the unloader conveyor is malfunctioning. Adjust
the machine.
------------------------------
Code: 15040621
Display: SS INTERLOCK EMERGENCY
Loader error: 15040621
Used by: QP132
Cause: The OUT conveyor pallet check sensor was on while the SS-axis was transporting a pallet.
Remedy: Check whether there is an unnecessary pallet on the unloader, or make sure the OUT conveyor
pallet confirmation sensor isn't malfunctioning.
------------------------------
Code: 15040622
Display: "SS INTERLOCK ERROR", "LD_ERR 15040622"
Used by:
Cause: The OUT conveyor pallet check sensor was on when the SS-axis was performing a pallet transport
start check..
Remedy: Check whether there is an unnecessary pallet on the unloader, or make sure the OUT conveyor
pallet confirmation sensor isn't malfunctioning.
------------------------------
Code: 15040630
Display: RCV_STOPPER RIZE TUP
Loader error: 15040630
Used by: QP132
第 1148 页
Cause: The return-conveyor's stopper is not engaging.
Remedy: Check operation using I/O commands (XO4C: RCV STPR ON) and adjust if necessary.
------------------------------
Code: 15040631
Display: RCV_STOPPER DOWN TUP
Loader error: 15040631
Used by: QP132
Cause: The return-conveyor's stopper is not disengaging.
Remedy: Check operation using I/O commands (XO4D: RCV STPR OFF) and adjust if necessary.
------------------------------
Code: 15040632
Display: RCV PLT NOT ARRV
Loader error: 15040632
Used by: QP132
Cause: An unloaded pallet has not arrived at the deceleration point.
Remedy: Check that the pallet is not somewhere other than the stopping position on the return-conveyor.
Check operation using I/O commands (X048: RCV DECEL PNT) and adjust if necessary.
------------------------------
Code: 15040633
Display: RCV PLT NOT EXIST
Loader error: 15040633
Used by: QP132
Cause: The pallet that passed through the return-conveyor's deceleration point has not arrived at the
pallet arrival check sensor.
Remedy: Check that the pallet is not somewhere in between the deceleration point and the arrival
verification position on the return-conveyor. Check operation using I/O commands (X049: RCV ARRV
CHK) and adjust if necessary.
------------------------------
Code: 15040634
Display: RCV_STOPPER2 RIZE TUP
Loader error: 15040634
Used by: QP132
Cause: The return-conveyor's stopper2 is not engaging.
Remedy: Check operation using I/O commands (XO6E: RCV STPR2 ON) and adjust if necessary.
This error only occurs when the machine is operated with 12 sixteen-inch pallets.
------------------------------
Code: 15040635
Display: RCV_STOPPER2 DOWN TUP
Loader error: 15040635
Used by: QP132
Cause: The return-conveyor's stopper2 is not disengaging.
Remedy: Check operation using I/O commands (XO77: RCV STPR2 OFF) and adjust if necessary.
This error only occurs when the machine is operated with 12 sixteen-inch pallets.
------------------------------
Code: 15040636
Display: RCV2 PLT NOT ARRV
Loader error: 15040636
Used by: QP132
Cause: An unloaded pallet has not arrived at the deceleration point2.
Remedy: Check that the pallet is not somewhere other than the stopping position on the return-conveyor.
Check operation using I/O commands (X065: RCV DECEL PNT2) and adjust if necessary.
第 1149 页