FUJI错误代码查询.pdf - 第593页

Remedy: Check the condition of the packages. ------------------------------ Code: 1205613B Display: Carrier pocket check error Used by: QP301 Cause: Packages detected in conveyed carrier. Remedy: Remove the packages, or …

100%1 / 5282
Used by: GP551
Cause: The machine attempted to move the Y-axis but was not able to because the Z-axis is in a position
(or may be in a position) where it is interfering with the camera (CX-axis).
Remedy: Move the Z-axis to a position where it does not interfere with the camera (CX-axis) or move the
camera (CX-axis) to its retract position.If this does not solve the problem, try checking whether the sensor
at the camera (CX-axis) retract position turns on and off correctly.
------------------------------
Code: 12056135
Display: Interlock Y-axis Lower cleaner
Used by: GP551
Cause: The machine attempted to move the Y-axis but was not able to because the Z-axis is in a position
(or may be in a position) where it is interfering with the lower cleaner.
Remedy: Move the Z-axis to a position where it does not interfere with the lower cleaner or move the lower
cleaner to its origin position. If this does not solve the problem, try checking whether the sensor at the
lower cleaner origin position turns on and off correctly.
------------------------------
Code: 12056136
Display: Interlock Y-axis Lower cleaner/camera
Used by: GP551
Cause: The machine attempted to move the Y-axis but was not able to because the Z-axis is in a position
(or may be in a position) where it is interfering with the lower cleaner and the camera (CX-axis). This
occurs if the lower cleaner is not at its origin or the camera (CX-axis) is not at its retract position when the
Z-axis attempts to move.
Remedy: Move the lower cleaner to its origin and the camera (CX-axis) to its retract position. If this does
not solve the problem, try checking whether the sensors at the lower cleaner origin position and the
camera (CX-axis) retract position turn on and off correctly.
------------------------------
Code: 12056137
Display: Change Station Door Open
Used by: QP132
Cause: The change station door sensor (X02A:CHGST DOOR OK) is not on when zero setting is
performed.
Remedy: Close and lock the door using the key.
------------------------------
Code: 12056138
Display: 维修保养钥匙错误
Used by: PCC
Cause: 维修保养钥匙处于ON,不能够自动运转。
Remedy: 请将维修保养钥匙设置为OFF。
------------------------------
Code: 12056139
Display: Parts pick-up error!
Used by: QP301
Cause: A part was still held by the FOL carrier during unloading.
Remedy: Check for remaining parts on the FOL carrier and check the action of the parts recognition
sensors.
------------------------------
Code: 1205613A
Display: Missing package error!
Used by: QP301
Cause: An empty pocket has been detected.
第 592 页
Remedy: Check the condition of the packages.
------------------------------
Code: 1205613B
Display: Carrier pocket check error
Used by: QP301
Cause: Packages detected in conveyed carrier.
Remedy: Remove the packages, or check the condition of the parts confirmation sensor.
------------------------------
Code: 1205613C
Display: Interlock Z-axis frame support
Used by: GP-551
Cause: An attempt was made to inch the Z-axis upwards, but inching cannot be performed as the side
clamp may contact the frame support.
Remedy: Lower the Z-axis to the point where the Y-axis interlock sensor (X034 Y AXIS ILK) turns on, and
ensure that the sensor is functioning correctly.
Perform inching from within the free inching command if it necessary to raise the Z-axis for purposes such
as Proper data measurement.
------------------------------
Code: 1205613D
Display: 应用程序错误
[Application Error]
Used by: QP3,GPX,NXTP
Cause: 发生了应用程序错误。
Remedy: 请重新启动机器。
<img src="$LKEY_ERRIMG_MC$/1205613D.PNG">
------------------------------
Code: 1205613E
Display: 联锁装置 Z2轴
Used by: NXTP
Cause: Z2轴不在退避位置。
Remedy: 1.请移动Z2轴到退避位置。
2.请确认Z2轴退避确认传感器(X01F)的ON/OFF动作。
3.请进行Z2轴的零点设定。
<img src="$LKEY_ERRIMG_MC$/1205613E.PNG">
------------------------------
Code: 1205613F
Display: 联锁装置 Z3轴
Used by: NXTP
Cause: Z3轴不在退避位置。
Remedy: 1.请移动Z3轴到退避位置。
2.请确认Z3轴退避传感器(X018)的ON/OFF动作。
3.请进行Z3轴的零点设定。
<img src="$LKEY_ERRIMG_MC$/1205613F.PNG">
------------------------------
Code: 12056150
Display: 未收存料盘托架。
不能使料盘电梯动作。
请确认料盘托架位置。
Used by: XP241,XP242
Cause: 料盘电梯移动时料盘收存确认传感器处于OFF。
Remedy: 请确认料盘往复臂、料盘板的位置。
第 593 页
请确认料盘收存确认传感器是否正常工作。
------------------------------
Code: 12056151
Display: 料盘电梯移动中确认料盘收存的传感器处于OFF。
不能使料盘电梯动作。
请确认料盘托架位置。
Used by: XP241,XP242
Cause: 料盘电梯移动时料盘收存确认传感器处于OFF。
Remedy: 请确认料盘往复臂、料盘板的位置。
请确认料盘收存确认传感器是否正常工作。
------------------------------
Code: 12056160
Display: Raised squeegee detected.
Used by: QP3
Cause: The fixed flux unit's squeegee is raised.
Remedy: Lower the squeegee, then push [READY ON].
------------------------------
Code: 12056169
Display: Holder Selection Error.
Used by: QP3
Cause: Unable to perform this process with the currently selected holder.
Remedy: Select the holder displayed in the parameter column and perform the process again.
------------------------------
Code: 1205616A
Display: 联锁 洗净剂喷嘴清洁器
Used by: GPX
Cause: 清洁器与洗净剂供应喷嘴有可能发生了干涉。
Remedy: 1.请用手将洗净剂移动到待机位置。
2.发生了干涉时,请与敝公司Support联系。
<img src="$LKEY_ERRIMG_MC$/EI0023.bmp">
------------------------------
Code: 1205616B
Display: 电路板凹凸检查钥匙错误
Used by: NXTP,GPX
Cause: 电路板凹凸检查钥匙处于ON自动运转不能启动。
Remedy: 请把电路板凹凸检查钥匙设定为OFF。
<img src="$LKEY_ERRIMG_MC$/1205616B.PNG">
------------------------------
Code: 1205616C
Display: 联锁 往复臂电路板转载检测
Used by: NXTP
Cause: 在往复臂动作时检测出电路板。
Remedy: 1.请确认电路板是否卡在搬运轨道上。
2.可考虑电路板不在正常的位置,请除去发生异常的电路板。
3.请确认搬运轨道间的电路板载入是否顺畅。
<img src="$LKEY_ERRIMG_MC$/1205616C.PNG">
------------------------------
Code: 1205616D
Display: 联锁 外部输入
Used by: NXTP
Cause: 因为进行了联锁输入的选项输入检测,不能启动指令。
第 594 页