FUJI错误代码查询.pdf - 第2320页
Code: 52??1813 Display: No "UNIT", "PALLET" - "BLOCK", "HEADER-" in the pallet data file. Used by: Cause: The specified pallet data file was read and "BLOCK", "HEADE…
above error is detected.
Remedy: Check the setting for "UNIT", "STRUCT" in the specified pallet data file.
------------------------------
Code: 52??1806
Display: Not pallet data file.
Used by:
Cause: The specified pallet data file is not pallet data. This report is made when the program is
downloaded, the pallet data is required in the applicable machine type and the above error is detected.
Remedy: Check the setting for "FILETYPE", "FILESTRUCT" in "UNIT", "STRUCT" - "BLOCK", "HEADER" in
the specified pallet data file.
------------------------------
Code: 52??1807
Display: Pallet data file read error.
Used by:
Cause: A read error occurred in the specified pallet data file.
Remedy: Check the specified pallet data file.
------------------------------
Code: 52??1808
Display: No machine type definition in specified pallet data file.
Used by:
Cause: The machine type is not defined in the header information in the specified pallet data file.
Remedy: Enter the "MCTYPE" item in the specified pallet data file.
------------------------------
Code: 52??1809
Display: Pallet data file already exists.
Used by:
Cause: The specified pallet data file already exists.
Remedy:
------------------------------
Code: 52??1810
Display: No "FILETYPE" entry in pallet data file.
Used by:
Cause: There is no "FILETYPE" entry in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified pallet
data file.
Remedy: "FILETYPE" is a mandatory item.
------------------------------
Code: 52??1811
Display: No "FILESTRUCT" entry in pallet data file.
Used by:
Cause: There is no "FILESTRUCT" entry in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified
pallet data file.
Remedy: "FILESTRUCT" is a mandatory item.
------------------------------
Code: 52??1812
Display: No "UNIT", "PALLET" in pallet data file or "UNIT", "PALLET" is not at the correct position.
Used by:
Cause: The specified pallet data file was read and "UNIT", "PALLET" was not found or "UNIT", "PALLET"
does not follow the correct unit.
Remedy: Check the setting for "UNIT", "PALLET" in the specified pallet data file. Alternatively, check the
setting for the "UNIT" line prior to "UNIT", "PALLET".
------------------------------
第 2319 页
Code: 52??1813
Display: No "UNIT", "PALLET" - "BLOCK", "HEADER-" in the pallet data file.
Used by:
Cause: The specified pallet data file was read and "BLOCK", "HEADER-" in "UNIT", "PALLET" was not
found.
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified pallet data file.
------------------------------
Code: 52??1814
Display: No "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the pallet data file.
Used by:
Cause: The specified pallet data file was read and "BLOCK", "PLTDT+" in "UNIT", "PALLET" was not
found.
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the specified pallet data file.
------------------------------
Code: 52??1815
Display: Format error in "UNIT", "PALLET" - "BLOCK", "HEADER-" in pallet data file.
Used by:
Cause: The specified pallet data file was read and a format error was detected in "BLOCK", "HEADER-" in
"UNIT", "PALLET".
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified pallet data file.
------------------------------
Code: 52??1816
Display: Format error in "UNIT", "PALLET" - "BLOCK", "PLTDT+" in pallet data file.
Used by:
Cause: The specified pallet data file was read and a format error was detected in "BLOCK", "PLTDT+" in
"UNIT", "PALLET".
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the specified pallet data file.
------------------------------
Code: 52??1820
Display: Format error in "MCTYPE" in "UNIT", "PALLET" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and a format error was detected in
"MCTYPE" in "BLOCK", "HEADER-".
Remedy: Check the setting for "MCTYPE" in "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified
pallet data file.
------------------------------
Code: 52??1821
Display: Format error in "NAME" in "UNIT", "PALLET" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and a format error was detected in
"NAME" in "BLOCK", "HEADER-".
Remedy: Check the setting for "NAME" in "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified pallet
data file.
------------------------------
Code: 52??1830
Display: No item definition line in "UNIT", "PALLET" - "BLOCK", "PLTDT+".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and the item definition line for
"BLOCK", "PLTDT+" was not found.
Remedy: Check the setting for the item definition line for "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the
specified pallet data file.
第 2320 页
------------------------------
Code: 52??1831
Display: No item definition for "GUISTN".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and the "GUISTN" entry in the
"BLOCK", "PLTDT+" item definition line was not found.
Remedy: Check the setting for "GUISTN" in the "UNIT", "PALLET" - "BLOCK", "PLTDT+" item definition line
in the specified pallet data file. "GUISTN" is a mandatory item.
------------------------------
Code: 52??1832
Display: Out of range value in "GUISTN" data.
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and there was an out of range value in
the "GUISTN" data in "BLOCK", "PLTDT+". When downloading, the relevant data is ignored.
Remedy: Check the setting for the "GUISTN" data line in "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the
specified pallet data file.
------------------------------
Code: 52??1833
Display: Insufficient values entered for "GUISTN"
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and the data lines for "GUISTN" in
"BLOCK", "PLTDT+" were insufficient.
Remedy: Check the settings for the "GUISTN" data lines in "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the
specified pallet data file. "GUISTN" must record all of the numbers from 1 up to the number required by
the applicable machine type.
------------------------------
Code: 52??2000
Display: No "UNIT", "PALLET" or "UNIT", "PALLET" is not at the correct position.
Used by:
Cause: "UNIT", "PROPER" was not found in the specified Proper data. Alternatively, "UNIT", "PROPER"
does not follow the correct unit.
Remedy: Check the setting for "UNIT", "PROPER" in the Proper data.
------------------------------
Code: 52??2001
Display: No ""UNIT", "PROPER" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER-" was not found in "UNIT", "PROPER" in the specified Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "HEADER-" in the Proper data.
------------------------------
Code: 52??2002
Display: No ""UNIT", "PROPER" - "BLOCK", "PROPDT-".
Used by:
Cause: "BLOCK", "PROPDT-" was not found in "UNIT", "PROPER" in the specified Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "PROPDT-" in the Proper data.
------------------------------
Code: 52??2005
Display: No ""UNIT", "PROPER" - "BLOCK", "IMAGE-".
Used by:
Cause: "BLOCK", "IMAGE" was not found in "UNIT", "PROPER" in the specified transmission image type
Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "IMAGE-" in the Proper data. Furthermore,
第 2321 页