Code: 11011327 Display: Non Used by: CP642,CP642M,CP643 Cause: The No.1 nozzle in the nozzle assignment table is less than 0.7 mm in size. Remedy: Use nozzle of less than 0.7 mm at a position other than No.1. -----------…

100%1 / 5282
so that it is within the range established in part data items,"Nozzle_size_min" and "Nozzle_size_max".
Alternatively, change the part data.
------------------------------
Code: 11011320
Display:
Used by:
Cause: Part data's nozzle number is not 1 or 2 on a CP.
Remedy: Check Part data.
------------------------------
Code: 11011321
Display:
Used by: CP3
Cause: There is a part higher than 4.5 mm encountered during a sequence (CP).
Remedy: Parts higher than 4.5 mm should be placed at the end of the placing sequences. Refer to Part
data for part heights.
------------------------------
Code: 11011322
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are over 255 mark sequences (Fiducial mark, block skip marks) (CP).
Remedy: Reduce the number of mark sequences.
------------------------------
Code: 11011323
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are mark read sequences for a machine which cannot read marks (CP). Alternately, a
production program with mark read sequences was transmitted but the Proper data has been deleted.
Remedy: Eliminate the mark read sequences if the machine does not read mark read sequences.
Otherwise, re-transmit Proper and Status data to the machine, and then transmit the production
program.
------------------------------
Code: 11011324
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are over 11 next devices set (CP3). There are over 31 next devices set(CP4,CP43, CP-
6/6M/65/642/652C). A next device loop does not exist (the machine never returns to the original device).
Remedy: Reduce the number of next devices. Check the next device settings (make sure a loop is formed).
------------------------------
Code: 11011325
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: In the production program the nozzle diameter is not set correctly (CP4).
Remedy: Set the nozzle diameter in the production program.
------------------------------
Code: 11011326
Display: same as code.
Used by: CP643
Cause: The item "Multiple PCB Set" in the production program indicates double
board production,but the sequence data contains no sequence for the second board.
Remedy: Set the item "Multiple PCB Set" to 1,or enter sequence for the second board.
------------------------------
第 33 页
Code: 11011327
Display: Non
Used by: CP642,CP642M,CP643
Cause: The No.1 nozzle in the nozzle assignment table is less than 0.7 mm in size.
Remedy: Use nozzle of less than 0.7 mm at a position other than No.1.
------------------------------
Code: 11011400
Display:
Used by: GL2,GL541
Cause: The application time (G) is out of range.
Remedy: Check the program.
------------------------------
Code: 11011401
Display:
Used by:
Cause: The application speed (U) is out of range.
Remedy: Check the program.
------------------------------
Code: 11011402
Display:
Used by:
Cause: The feeder specification (F) is not set at 1 or 2.
Remedy: Check the program.
------------------------------
Code: 11011403
Display:
Used by:
Cause: The feeder specification (F) change over on even numbered devices.
Remedy: Check the program.
------------------------------
Code: 11011404
Display:
Used by:
Cause: The DX offset is out of range.
Remedy: Check the program.
------------------------------
Code: 11011405
Display:
Used by:
Cause: The DY offset is out of range.
Remedy: Check the program.
------------------------------
Code: 11011406
Display:
Used by:
Cause: The DQ offset is out of range.
Remedy: Check the program.
------------------------------
Code: 11011600
Display:
Used by: IP2
第 34 页
Cause: Holder number check error (sequences 0001~0125).
Remedy: Check the holder numbers on sequences 0001~0125. On the IP2, there is a check to make sure
that every sequence has a holder number assigned. If there is no holder assigned to a sequence, an error
occurs.
------------------------------
Code: 11011601
Display:
Used by: IP2
Cause: Holder number check error (sequences 0126~0250).
Remedy: Check the holder numbers on sequences 0126~0250. On the IP2, there is a check to make sure
that every sequence has a holder number assigned. If there is no holder assigned to a sequence, an error
occurs.
------------------------------
Code: 11011602
Display:
Used by: IP2
Cause: Holder number check error (sequences 0251~0375).
Remedy: Check the holder numbers on sequences 0251~0375. On the IP2, there is a check to make sure
that every sequence has a holder number assigned. If there is no holder assigned to a sequence, an error
occurs.
------------------------------
Code: 11011603
Display:
Used by: IP2
Cause: Holder number check error (sequences 0376~0500).
Remedy: Check the holder numbers on sequences 0376~0500. On the IP2, there is a check to make sure
that every sequence has a holder number assigned. If there is no holder assigned to a sequence, an error
occurs.
------------------------------
Code: 11011604
Display:
Used by: IP2
Cause: Holder number check error (sequences 0501~0625).
Remedy: Check the holder numbers on sequences 0501~0625. On the IP2, there is a check to make sure
that every sequence has a holder number assigned. If there is no holder assigned to a sequence, an error
occurs.
------------------------------
Code: 11011605
Display:
Used by: IP2
Cause: Holder number check error (sequences 0626~0750).
Remedy: Check the holder numbers on sequences 0626~0750. On the IP2, there is a check to make sure
that every sequence has a holder number assigned. If there is no holder assigned to a sequence, an error
occurs.
------------------------------
Code: 11011606
Display:
Used by: IP2
Cause: Holder number check error (sequences 0751~0875).
Remedy: Check the holder numbers on sequences 0751~0875. On the IP2, there is a check to make sure
that every sequence has a holder number assigned. If there is no holder assigned to a sequence, an error
第 35 页