FUJI错误代码查询.pdf - 第1630页

data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level. ------------------------------ Code: 1D300009 Display: Same as code. Used by: Cause: A sufficient number of leads could no…

100%1 / 5282
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D300003
Display: Same as code.
Used by:
Cause: The camera cannot acquire a part image. The part is too large.
Remedy: Check the camera, video processing board, cable, and focus. Check the part. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D300004
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Inspect the part for missing leads, and check lead width. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D300005
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D300006
Display: Same as code.
Used by:
Cause: Only one lead could be found.
Remedy: Inspect the part for missing leads, and check the part supply direction. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D300007
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D300008
Display: Same as code.
Used by:
Cause: The lead pitch is too wide.
Remedy: Check the lead pitch and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
第 1629 页
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D300009
Display: Same as code.
Used by:
Cause: A sufficient number of leads could not be found.
Remedy: Check the lead quantity and the part supply direction. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D30000B
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D30000C
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D30000D
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D30000E
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D30000F
Display: Same as code.
Used by:
Cause: Processing error.
Remedy: Check the part's shape. Check for a missing part.
------------------------------
Code: 1D300010
Display: Same as code.
第 1630 页
Used by:
Cause: The lead pitch is incorrect.
Remedy: Check the lead pitch and the lead quantity. Lead thickness is critical to lead detection. Leads
can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part data. A
variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D300011
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the part supply direction.
------------------------------
Code: 1D300013
Display: Same as code.
Used by:
Cause: The lead quantity is set to 3, but only 2 leads could be found.
Remedy: Check the part's shape. Check the part supply direction. Check the Part data and the Device
data.
------------------------------
Code: 1D300014
Display: Same as code.
Used by:
Cause: The lead quantity is set to 2, but 3 leads were found.
Remedy: Check the part's shape. Check the part supply direction. Check the Part data and the Device
data.
------------------------------
Code: 1D300015
Display: Same as code.
Used by:
Cause: The part is too long in the X direction.
Remedy: Check the part's shape. (The allowable error is 20% greater than the input value.) Check the
part supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D300016
Display: Same as code.
Used by:
Cause: The part is too short in the X direction.
Remedy: Check the part's shape. (The allowable error is 20% less than the input value.) Check the part
supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D308002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D308100
Display: Same as code.
Used by:
第 1631 页