FUJI错误代码查询.pdf - 第496页
------------------------------ Code: 1205018D Display: D2-table stopper sensor error. Used by: CP-742ME, CP-742E, CP-752E Cause: The D2-table stopper UP sensor (X096) failed to switch on. Remedy: Check the D1-table stopp…
Code: 12050182
Display: Shutter 1 Alarm
Lower limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the lower-limit sensor for the shutter of the D1-axis.
Remedy: Check the lower-limit sensor for the shutter of the D1-axis.
------------------------------
Code: 12050183
Display: Shutter 2 Alarm
Upper limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the upper-limit sensor for the shutter of the D2-axis.
Remedy: Check the upper-limit sensor for the shutter of the D2-axis.
------------------------------
Code: 12050184
Display: Shutter 2 Alarm
Lower limit sensor error
Used by: CP4,CP42,CP43,CP6,CP6M,CP65,CP642,CP642M,CP643
Cause: An alarm has occurred at the lower-limit sensor for the shutter of the D2-axis.
Remedy: Check the lower-limit sensor for the shutter of the D2-axis.
------------------------------
Code: 12050188
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper UP sensor (X080) failed to switch on.
Remedy: Check the D1-table stopper UP sensor.
------------------------------
Code: 12050189
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper DOWN sensor (X080) failed to switch off.
Remedy: Check the D1-table stopper DOWN sensor.
------------------------------
Code: 1205018A
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper DOWN sensor (X080) failed to switch on.
Remedy: Check the D1-table stopper DOWN sensor.
------------------------------
Code: 1205018B
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1-table stopper UP sensor (X080) failed to switch off.
Remedy: Check the D1-table stopper UP sensor.
------------------------------
Code: 1205018C
Display: D1-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error was detected at the D1-table stopper UP/DOWN sensors. The UP sensor (X080) and
the DOWN sensor (X081) are both on.
Remedy: Check the sensors.
第 495 页
------------------------------
Code: 1205018D
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper UP sensor (X096) failed to switch on.
Remedy: Check the D1-table stopper UP sensor.
------------------------------
Code: 1205018E
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper DOWN sensor (X097) failed to switch off.
Remedy: Check the D2-table stopper DOWN sensor.
------------------------------
Code: 1205018F
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper DOWN sensor (X097) failed to switch on.
Remedy: Check the D2-table stopper DOWN sensor.
------------------------------
Code: 12050190
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D2-table stopper UP sensor (X096) failed to switch off.
Remedy: Check the D2-table stopper UP sensor.
------------------------------
Code: 12050191
Display: D2-table stopper sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error was detected at the D2-table stopper UP/DOWN sensors. The UP sensor (X096) and
the DOWN sensor (X097) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050192
Display: D1 pallet UP error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1 pallet UP sensor (X08C) is on.
Remedy: Lower the D1 pallet.
------------------------------
Code: 12050193
Display: D1 pallet sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D1 pallet UP sensor. The D1 pallet UP sensor (X08C) and DOWN
sensor (X07F) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050194
Display: D2 pallet UP error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The D1 pallet UP sensor (X0A2) is on.
Remedy: Lower the D2 pallet.
------------------------------
第 496 页
Code: 12050195
Display: D2 pallet sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D2 pallet UP sensor. The D2 pallet UP sensor (X0A2) and DOWN
sensor (X095) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050196
Display: Currently in maintenance mode!
Used by: NP2,QP3
Cause: The part supply unit is currently in maintenance mode.
Remedy: Leave the maintenance mode to start automatic operation.
------------------------------
Code: 12050197
Display: D2 pallet position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D2 pallet UP (X0A2) and DOWN (X095) sensors. Both of these
sensors are off.
Remedy: Lower the D2 pallet.
------------------------------
Code: 12050198
Display: D1 pallet position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: D1 pallet position error.A logic error occurred at the D1 pallet UP (X08C) and DOWN (X07F)
sensors.Both of these sensors are off.
Remedy: Lower the D1 pallet.
------------------------------
Code: 12050199
Display: 温度超范围
Used by: NXTP
Cause: 机内温度超范围。
Remedy: 1)请确认温控单元。2)请确认温度设定是否合理 3)请确认机外温度是否超出下列范围:合理温度度
±5℃。温控单元的温度调节范围为±5度。4)如果温度没有显示,则有可能是控制器出了故障。
<img src="$LKEY_ERRIMG_MC$/12050199.PNG">
------------------------------
Code: 1205019A
Display: 湿度在合适范围外
Used by: NXTP
Cause: 机内湿度在合适范围之外。
Remedy: 1)请调整湿度。
2)请确认湿度设定范围是否合适。
<img src="$LKEY_ERRIMG_MC$/1205019A.PNG">
------------------------------
Code: 1205019B
Display: 清洗剂蓄水盘已满
Used by: NXTP
Cause: 清洗剂蓄水盘已满。
Remedy: 请将被堵塞的清洗剂输送管路打通。
<img src="$LKEY_ERRIMG_MC$/EI0243.png">
------------------------------
Code: 120501A0
第 497 页