FUJI错误代码查询.pdf - 第1147页

Display: Abolished. Used by: QP122 Cause: Abolished. Remedy: Abolished. ------------------------------ Code: 15040608 Display: )NOT FIT PCB DATA Loader error: 15040608 Used by: QP132 Cause: The board unload position calc…

100%1 / 5282
Code: 15040512
Display: In-shifter pallet positioning error.
Used by: QP132
Cause: The pallet is not at the correct position or the pallet arrival sensor (X050 P. IN ARRV CK) is not
functioning correctly.
Remedy: Manually move the pallet on the in-shifter to the left and confirm that it is detected by the pallet
arrival sensor. If the pallet is not detected, check the condition of the sensor.
------------------------------
Code: 15040600
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040601
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040602
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040603
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040604
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040605
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040606
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040607
第 1146 页
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040608
Display: )NOT FIT PCB DATA
Loader error: 15040608
Used by: QP132
Cause: The board unload position calculations could not be made.
Remedy: If there is a board remaining in the machine, then unload the board and restart.
------------------------------
Code: 15040609
Display: OUT INTERLOCK PLT PASSED1 ON
LD_ERR 15040609
Used by:
Cause: The production conveyor pallet popped up onto the unloader.
Remedy: Return the pallet to the production conveyor or slide the pallet onto the unloader. Check the
operation of the pallet unload pass-through-check 1 sensor.
------------------------------
Code: 1504060A
Display: OUT INTERLOCK PLT PASSED2 ON
LD_ERR 15040609
Used by:
Cause: The pallet on the return conveyor popped off the unloader.
Remedy: Slide the pallet onto the return conveyor or return the pallet to the unloader. Check the
operation of the pallet unload pass-through-check 2 sensor.
------------------------------
Code: 1504060B
Display: OUT INTERLOCK PCB CLAMP ON
LD_ERR 1504060B
Used by:
Cause: This error is the result of the board clamp on the out-conveyor side being in the clamped status.
Remedy: Unclamp the board clamp on the out-conveyor side. Check the operation of the exit board
pusher clamp limit sensor.
------------------------------
Code: 1504060C
Display: OUT INTERLOCK PCB PASSED ON
Loader error: 1504060C
Used by: QP132
Cause: The board on the out-conveyor popped off the unloader.
Remedy: Return the board to the unloader or slide it onto the out-conveyor. Check the operation of the
out-conveyor board pass-through-check sensor.
------------------------------
Code: 1504060D
Display: OUT INTERLOCK HOOK PULLED OFF
LD_ERR 1504060D
Used by:
Cause: The PO-axis board hooks was not in the released status.
Remedy: Release the PO-axis board hooks. Check the operation of the PO-axis hook release status
sensor.
第 1147 页
------------------------------
Code: 1504060E
Display: OUT INTERLOCK SS NOT ORG POS
LD_ERR 1504060E
Used by:
Cause: The SS-axis is not at its origin position.
Remedy: Move the SS-axis to its origin position.
------------------------------
Code: 15040610
Display: SHUTTER OPEN TIMEUP
Loader error: 15040610
Used by: QP132
Cause: The opening operation of the unload shutter was not completed within the set amount of time.
Remedy: Check the unload shutter operation and the operation of the shutter open check sensor.
------------------------------
Code: 15040611
Display: SHUTTER CLOSE TIMEUP
Loader error: 15040611
Used by: QP132
Cause: The closing operation of the unload shutter was not completed within the set amount of time.
Remedy: Check the unload shutter operation and the operation of the shutter close check sensor.
------------------------------
Code: 15040620
Display: PALLET ON UNLOADER
Loader error: 15040620
Used by: QP132
Cause: Unloader conveyor pallet arrival sensor 1 was on when the machine attempted indexing during
initiation or pallet switchover.
Remedy: The ID reader at the OUT end is misreading, or the unloader conveyor is malfunctioning. Adjust
the machine.
------------------------------
Code: 15040621
Display: SS INTERLOCK EMERGENCY
Loader error: 15040621
Used by: QP132
Cause: The OUT conveyor pallet check sensor was on while the SS-axis was transporting a pallet.
Remedy: Check whether there is an unnecessary pallet on the unloader, or make sure the OUT conveyor
pallet confirmation sensor isn't malfunctioning.
------------------------------
Code: 15040622
Display: "SS INTERLOCK ERROR", "LD_ERR 15040622"
Used by:
Cause: The OUT conveyor pallet check sensor was on when the SS-axis was performing a pallet transport
start check..
Remedy: Check whether there is an unnecessary pallet on the unloader, or make sure the OUT conveyor
pallet confirmation sensor isn't malfunctioning.
------------------------------
Code: 15040630
Display: RCV_STOPPER RIZE TUP
Loader error: 15040630
Used by: QP132