FUJI错误代码查询.pdf - 第65页

------------------------------ Code: 1101C02F Display: Used by: Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device numbers 1 to 3 or 85 to 87. This error applies to seque…

100%1 / 5282
numbers 1 to 3 or 85 to 87. This error applies to sequences 141 to 160.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C028
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 161 to 180.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C029
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 181 to 200.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C02A
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 201 to 220.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C02B
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 221 to 240.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C02C
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 241 to 260.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C02D
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 261 to 280.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C02E
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 281 to 300.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
第 64 页
------------------------------
Code: 1101C02F
Display:
Used by:
Cause: Even though the machine is set to use the MTU-I or MTU-II, the program attempts to use device
numbers 1 to 3 or 85 to 87. This error applies to sequences 301 to the final sequence.
Remedy: Set values outside the range 1 to 3 or 85 to 87 for "D" in N_data in the production program.
------------------------------
Code: 1101C030
Display:
Used by: IP3
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 1 to 20.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C031
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 21 to 40.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C032
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 41 to 60.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C033
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 61 to 80.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C034
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 81 to 100.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C035
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 101 to 120.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C036
第 65 页
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 121 to 140.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C037
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 141 to 160.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C038
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 161 to 180.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C039
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 181 to 200.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C03A
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 201 to 220.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C03B
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 221 to 240.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C03C
Display:
Used by:
Cause: The coordinates specified for the X-axis in placing sequence data are out of range in the +
direction. This error applies to sequences 241 to 260.
Remedy: Set a correct "X" value in N_data in the production program.
------------------------------
Code: 1101C03D
Display:
Used by:
第 66 页