Cause: The maximum pulse count for movement of the PMC X-axis in the minus direction was not specified. Remedy: Specify 1058 + offset. Min Limit Position X in Proper data, where offset = (PMC No. - 1)*50) ---------------…

100%1 / 5282
Cause: The PMC's reference parts eject position Y is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Parts Eject Pos_Y" to the correct value. This Proper data item exists
for each module. Module one is number 722 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0D
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?0E
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?0F
Display: Same as Code.
Used by: QP132
Cause: The PMC's Y-axis retract position is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Escape Pos Y" to the correct value. This Proper data item exists for
each module. Module one is number 724 in Proper data. Thereafter, add (PMC No. -1) times 82 to locate
this item for each module.
------------------------------
Code: 11025?10
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?11
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?12
Display: Same as Code.
Used by: QP132
Cause: The PMC's X-axis extended position is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Max Limit Position X" to the correct value. This Proper data item
exists for each module. Module one is number 728 in Proper data. Thereafter, add (PMC No. -1) times 82
to locate this item for each module.
------------------------------
Code: 11025?13
Display: 11025?13
Used by:
第 179 页
Cause: The maximum pulse count for movement of the PMC X-axis in the minus direction was not
specified.
Remedy: Specify 1058 + offset. Min Limit Position X in Proper data, where offset = (PMC No. - 1)*50)
------------------------------
Code: 11025?14
Display: Same as Code.
Used by: QP132
Cause: The PMC's Y-axis extended position is not set.
Remedy: Set the Proper data item "Max Limit Position Y" to the correct value. This Proper data item exists
for each module. Module one is number 729 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?15
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?16
Display: Data Check Error [11025?16]
Used by: QP132
Cause: The camera center for the AB nozzle and the E nozzle is not set.
Remedy: Perform the Proper data measurement of AB and E nozzles' camera center or check Proper data
items 276?467.
------------------------------
Code: 11025?17
Display: Data Check Error [11025?17]
Used by: QP132
Cause: The camera center for the CD nozzle and the F nozzle is not set.
Remedy: Perform the Proper data measurement of CD and F nozzles' camera center or check Proper data
items 276?467.
------------------------------
Code: 11025?18
Display: Data Check Error [11025?18]
Used by: QP132
Cause: The value for the lean tolerance item is out of range.
"?" indicates the module number in hexadecimal notation. "0" indicates PMC 16.
Remedy: The lean tolerance range for a PMC is -50 to +50 1/1000 deg.
Set the Proper data item "739. Lean offset" (PMC 1) to a value in the range. For other Proper data
numbers (module number - 1) x 82.
------------------------------
Code: 11032000
Display:
Used by: GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3
Cause: Status data's Error setting is out of range.
Remedy: Check the Error setting in Status data.
------------------------------
Code: 11032001
Display:
Used by: IP1
Cause: Status data's Recovery_count setting is out of range.
第 180 页
Remedy: Check the Recovery_count setting in Status data.
------------------------------
Code: 11032002
Display:
Used by: GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3
Cause: Status data's Production_report setting is out of range.
Remedy: Check the Production_report setting in Status data.
------------------------------
Code: 11032003
Display: 11032003
Used by: GSP5,GP551,GP6
Cause: The error setting in status data is inappropriate.
Remedy: Check the error setting in status data. Auto_recovery cannot be used on the GSP series.
Therefore, enable Error_stop or Error_pass and retransmit the status data to the machine.
------------------------------
Code: 11050001
Display: Program Check NG
Pallet ID is not specified (FCP651C)
Used by: CP652C
Cause: The ID of the pallet to be used in production has not been specified.
Remedy: Use the [PROGRAM] -> [DEVICE] -> [PALLET ID] command sequence at the machine to specify
the pallet ID. Edit the pallet ID table, then retransmit (FCP651C).
------------------------------
Code: 11050002
Display: 11050002
Used by: CP652C
Cause: Overlapping pallet ID numbers have been set in the pallet ID table.
Remedy: Edit the pallet ID table, then retransmit.
------------------------------
Code: 11060001
Display:
Used by:
Cause: The specified module number is less than 1
Remedy: None.
------------------------------
Code: 11060002
Display:
Used by:
Cause: The specified module number has not been transmitted.
Remedy: None.
------------------------------
Code: 11060003
Display:
Used by:
Cause: There is no empty module block
Remedy: Delete programs 1~9 at the machine.
------------------------------
Code: 11060004
Display:
Used by:
Cause: There is no empty data area