FUJI错误代码查询.pdf - 第463页

Code: 12037A2? Display: INTL SRV initialize error Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GP551,GP6 Cause: Initialization of the intelligent servo board is not complete. This error occurred …

100%1 / 5282
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 120377??
Display: SECS1 LINK creation error
Used by: CP3,CP5,GP551,GP6,QP242,QP201,QP202,QP203
Cause: An error occurred due to a lack of memory and duplicated settings when an attempt was made to
generate the unit control block (UCB) for the SECS1 module. This error occurred when Fuji OS system
call_secs1_link() was used. The last two numbers in the error code indicate the unit in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 120378??
Display: SECS2 LINK creation error
Used by: CP3,CP5,QP242,QP201,QP202,QP203
Cause: An error occurred due to a lack of memory and duplicated settings when an attempt was made to
generate the unit control block (UCB) for the SECSII module. This error occurred when Fuji OS system
call_secs2_link() was used. The last two numbers in the error code indicate the unit in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 120379??
Display: HT LINK creation error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GP551
Cause: An error occurred due to a lack of memory and duplicated settings when an attempt was made to
generate the unit control block (UCB) for the handy terminal. This error occurred when Fuji OS system
call_ht_link() was used. The last two numbers in the error code indicate the unit in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A0?
Display: INTL SRV creation error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GP551,GP6
Cause: An error occurred due to a lack of memory when an attempt was made to generate the driver for
the intelligent servo board. This error occurred when Fuji OS system call_create_intl_srv() was used. The
last number in the error code indicates the board in which the error occurred. 0 indicates the first board.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A1?
Display: INTL SRV creation error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GP551,GP6
Cause: An attempt was made to generate the driver for the intelligent servo board but the board was not
in the "Ready" state. This error occurred when Fuji OS system call_create_intl_srv() was used. The last
number in the error code indicates the board in which the error occurred. 0 indicates the first board.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
第 462 页
Code: 12037A2?
Display: INTL SRV initialize error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GP551,GP6
Cause: Initialization of the intelligent servo board is not complete. This error occurred when Fuji OS
system call_intl_init_chk() was used. The last number in the error code indicates the board number in
which the error occurred. 0 indicates the first board.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A3?
Display: PI SRV creation error
Used by:
Cause: An error occurred when an attempt was made to generate the driver which performs servo driver
PI control. This error occurred when Fuji OS system call_create_pi_srv() was used. The last number in
the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A4?
Display: TBA SRV creation error
Used by: CP3
Cause: An error occurred when an attempt was made to generate the driver which controls the
acceleration speed of the servo driver. This error occurred when Fuji OS system call_create_tba_srv() was
used. The last number in the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A5?
Display: OLD SRV creation error
Used by: CP4-1,CP4-2,CP4-3,GL541,GP551,GP6
Cause: An error occurred during an attempt to generate the driver which controls the target value. This
error occurred when Fuji OS system call_create_old_srv() was used. The last number in the error code
indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A6?
Display: CNT SRV creation error
Used by:
Cause: An error occurred when an attempt was made to generate the counter driver for the system which
uses 8253 (PIT). This error occurred when Fuji OS system call_create_cnt_srv() was used. The last
number in the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A7?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GL541,GP551,GP6
Cause: An error occurred due to a lack of memory when an attempt was made to generate the
deceleration function data used by the servo. This error occurred when Fuji OS system
call_create_reduce() was used. The last number in the error code indicates the axis in which the error
第 463 页
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A8?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo because the parameter-specified deceleration time was too long. This error occurred when Fuji
OS system call_create_reduce() was used. The last number in the error code indicates the axis in which
the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A9?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo because the parameter-specified generate size was out of range. This error occurred when Fuji
OS system call_create_reduce() was used. The last number in the error code indicates the axis in which
the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AA?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo. This error occurred when Fuji OS system call_create_reduce() was used. The last number in
the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AB?
Display: Accel data creation error
Used by: CP3
Cause: An error occurred due to a lack of memory when an attempt was made to generate the
acceleration function data used by the servo. This error occurred when Fuji OS system
call_create_reduce() was used. The last number in the error code indicates the axis in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AC?
Display: Accel data creation error
Used by: CP3
Cause: An error occurred when an attempt was made to generate the acceleration function data used by
the servo because the specified parameter was unsuitable. This error occurred when Fuji OS system
call_create_accel() was used. The last number in the error code indicates the axis in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
第 464 页