FUJI错误代码查询.pdf - 第738页

"Zero Set Not Complete" (QP2)(QP132) PM?? ERROR Code:******** (QP132) Coplanarity error(NP2,QP3) Used by: QP242,QP201,QP202,QP203,QP132,NP2,QP3 Cause: The command could not be executed because zero setting has …

100%1 / 5282
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(PMC Error)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command could not be executed because the machine is stopped due to a PMC error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, then use commands to dump parts. If the problem
occurs again, use a reset-start to transmit the control software to the PMCs. If the problem occurs again,
faulty hardware such as the PMC control board, servo amps or servo boards may be the cause.
------------------------------
Code: 12070?83
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Sequence Number Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Sequence number error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMC. If the problem is recurring, issues such as a
faulty production program or PMC control board may be the cause.
The maximum number of sequences per production program is 5000, and the maximum number of
sequences for a PLM (PM), including mark sequences is 1000.
------------------------------
Code: 12070?84
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Seq Rationality Check Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Sequence rationality check error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program, and execute flush out processing. If the problem occurs again,
retransmit the control software to the PMCs
------------------------------
Code: 12070?85
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Req Command (ST Not Conect)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A handy terminal command request was issued even though there is no handy terminal
connected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?86
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 737 页
"Zero Set Not Complete" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Coplanarity error(NP2,QP3)
Used by: QP242,QP201,QP202,QP203,QP132,NP2,QP3
Cause: The command could not be executed because zero setting has not been completed. This error
also occurs if power to the PMC is turned off and on again after the machine is restarted following
completion of zero setting.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
The LLL zero setting has not been completed.(NP2,QP3)
Remedy: Execute zero setting.
Perform a zero setting operation.(NP2,QP3)
------------------------------
Code: 12070?87
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Axis Incorrectly Specified" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The axis to perform an action has been incorrectly specified.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?88
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mach Stop Due to Vision Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: The machine has stopped due to a vision processing error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Remove the cause of the vision processing error, press the RESET switch, and restart the
machine.
------------------------------
Code: 12070?89
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mach Stop Due to Recv Count" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: The machine has stopped after performing the maximum number of recoveries.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Remove the cause of the recoveries, press the RESET switch, and restart the machine.
------------------------------
Code: 12070?8A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Prog Trans before Request" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
第 738 页
Cause: Program data has been transmitted without a program transmission request.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?8B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Prog Trans Packet Too Long" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A program data transmission packet was too long.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?8C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Requested Prog incorrect" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The requested program data was incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program and press the RESET button to clear the error, or restart the
machine. If the problem occurs again, use a reset-start to transmit the control software to the PMC. If the
problem is recurring, issues such as a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?8D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Attribute Packet Too Long" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An attribute data transmission packet was too long.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?8E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Attribute Packet Too Long" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The requested attribute data was incorrect
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 739 页