Remedy: Prepare the reject parts conveyor. If parts can be rejected to positions other than the conveyor, change the [Reject Position] in part data to a position other than the conveyor. ------------------------------ Co…
Code: 1204A206
Display:
Used by:
Cause: The 100 deg. rough position check for the D axis could not be performed at the machine within
the preset time. Therefore, when the part was at station 5 there was no guarantee that it would be placed
correctly, so the part was rejected and recovery carried out.
Remedy: If this error happens frequently, the servos need adjusment. Contact Fuji.
------------------------------
Code: 1204A207
Display:
Used by:
Cause: The 100 deg. rough position check for each axis (vision processing) could not be performed at the
machine within the preset time. Therefore, when the part was at station 5 there was no guarantee that it
would be placed correctly, so the part was rejected and recovery carried out.
Remedy: If this error happens frequently, the servos need adjusment. Contact Fuji.
------------------------------
Code: 1204A208
Display:
Used by:
Cause: Automatic operation has been canceled due to a rear fence alarm. The nozzle at station 1 is not
set so it is impossible to determine which part has been picked. This error occurs only on the FCP-IV due
to the method in which the emergency stop is carried out.
Remedy: The part in question is discarded and auto-recovery is carried out.
------------------------------
Code: 1204A210
Display: Reject conveyor error!
Used by: NP2,QP3
Cause: Failed to reject part onto the reject parts conveyor.
Remedy: Check the condition of the parts reject conveyor.
------------------------------
Code: 1204A211
Display: Reject conveyor error!
Used by: QP3
Cause: A part that is to be rejected is set to be rejected to the conveyor but a reject parts conveyor that
can handle the rejected part cannot be found.
Remedy: Parts cannot be rejected when the part size in the both the X- and Y-direction exceeds the
conveyor width. Set a reject parts conveyor that can handle the part.
If locations other than the conveyor can be used for the rejected part, change the [Reject Position]
setting in part data to a location that can handle the part.
------------------------------
Code: 1204A212
Display: Eject conveyor error
Used by: QP3
Cause: The part cannot be rejected as the part dimensions (X and Y) are greater than the width of the
conveyor.
Remedy: Prepare a conveyor suitable for the part size.
------------------------------
Code: 1204A213
Display: Reject conveyor error!
Used by: QP3
Cause: The conveyor was specified for rejecting parts but the reject parts conveyor was not ready.
第 481 页
Remedy: Prepare the reject parts conveyor. If parts can be rejected to positions other than the conveyor,
change the [Reject Position] in part data to a position other than the conveyor.
------------------------------
Code: 1204A300
Display: Coplanarity Err
Used by: IP1,IP2,IP3
Cause: The results of coplanarity calculations indicate that the height of at least one lead exceeds the set
tolerance (Coplanarity item 2.Coplanarity_tolerance).
Remedy: Check whether the leads are coplanar. Check that the value set in 2.Coplanarity_tolerance is
not too small.
------------------------------
Code: 1204A301
Display: Linearity Err
Used by: IP1,IP2,IP3
Cause: The measurement indicates that the height of at least one lead exceeds the set tolerance
(Coplanarity item 3.Linearity_tolerance).
Remedy: Check whether the lead linearity is within set limits. Check that the value set in
3.Linearity_tolerance is not too small.
------------------------------
Code: 1204A302
Display: Lead qty Err
Used by: IP1,IP2,IP3
Cause: The measurement indicates that the number of leads on the part are not the same as the Qty in
Part data.
Remedy: Check that some leads are not bent. Confirm that the number input in Vision datals
10.lead_length,11.Lead_length_y, and in Side data's Body_size and Qty are correct.
------------------------------
Code: 1204A303
Display: Scan pos Err
Used by: IP1,IP2,IP3
Cause: Coplanarity check cannot be done because the point at which the part was picked was too close
to the leads (i.e., if the check was performed the nozzle might hit the sensor).
Remedy: Check that the part size and lead length are appropriate. Check that the part picking position is
not at the corner of the part.
------------------------------
Code: 1204A401
Display: No response from the splicing detection sensor.
Used by:
Cause: There was no response from the splicing detection sensor, even though a splicing report was
submitted from the Handy Terminal.
The splicing clip may have dropped off, or the splicing detection sensor may be out of order.
The parameter indicates the target slot number.
Remedy: Check that the splicing detection sensor is operating correctly, and that the splicing clip has not
dropped off the tape.
------------------------------
Code: 1204A402
Display: No splicing report.
Used by:
Cause: Splicing has been detected, but no splicing report has been received for that slot.
No splicing report was submitted from the Handy Terminal, or the splicing detection sensor may be
out of order.
第 482 页
The parameter indicates the target slot number.
Remedy: Carry out a device check at the device check screen.
Check that the splicing detection sensor is operating correctly.
------------------------------
Code: 1204B000
Display: “毛巾余量不足 上”/“毛巾余量不足 下”
Used by: GSP5,GP551,GP6,GPX,NXTP
Cause: 上或下的毛巾余量计数器到了设定值。或者,由传感器测出。
Remedy: 请供应毛巾。
<img src="$LKEY_ERRIMG_MC$/1204B000.PNG">
------------------------------
Code: 1204B001
Display: 溶剂的余量不足了
Used by: GSP5,GP551,GP6,GPX.NXTP
Cause: 没有清洁用的溶剂。
Remedy: 请添加溶剂。
<img src="$LKEY_ERRIMG_MC$/1204B001.PNG">
------------------------------
Code: 1204B002
Display: Solder Supply Remaining Level Warning
Used by: GP551,GP6,NXTP
Cause: The solder has run out.
Remedy: Supply solder.
<img src="$LKEY_ERRIMG_MC$/1204B002.PNG">
------------------------------
Code: 1204B003
Display: Backlight brightness deficiency.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The backlight brightness for the nozzle(s) indicated at the Parameter area is insufficient. When
several nozzles are involved, the nozzle backlight disks may be soiled.
Remedy: Replace the nozzle(s). If this error occurs frequently, there may be an ultraviolet lamp problem.
In this case, replace the light source.
------------------------------
Code: 1204B005
Display: 清洁纸剩余量警告
Used by: NXTP
Cause: 超过了清洁纸的剩余量。
Remedy: 请进行供应清洁纸的准备。
<img src="$LKEY_ERRIMG_MC$/1204B005.PNG">
------------------------------
Code: 1204B006
Display: 锡膏余量不足
Used by: NXTP, GPX-C
Cause: 锡膏自动供应器内的锡膏即将用完。
Remedy: 请准备新锡膏。
<img src="$LKEY_ERRIMG_MC$/1204B006.png">
------------------------------
Code: 1204B007
Display: 焊锡杯托架脱落
Used by: NXTP,GPX-C
Cause: 焊锡杯托架没有正确地安装在机器上。