FUJI错误代码查询.pdf - 第196页

------------------------------ Code: 1107430D Display: Used by: IP2 Cause: Proper data's recovery setting is out of range. Remedy: Check the Proper data. ------------------------------ Code: 1107430E Display: Used b…

100%1 / 5282
Used by: IP2
Cause: Proper data's Y axis deceleration point is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074305
Display:
Used by: IP2
Cause: Proper data's T axis deceleration point is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074306
Display:
Used by: IP2
Cause: Proper data's X axis deceleration time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074307
Display:
Used by: IP2
Cause: Proper data's Y axis deceleration time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074308
Display:
Used by: IP2
Cause: Proper data's T axis deceleration time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074309
Display:
Used by: IP2
Cause: Proper data's T axis reference location is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430A
Display:
Used by: IP2
Cause: Proper data's X axis top speed is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430B
Display:
Used by: IP2
Cause: Proper data's Y axis top speed is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430C
Display:
Used by: IP2
Cause: Proper data's Z axis top speed is out of range.
Remedy: Check the Proper data.
第 195 页
------------------------------
Code: 1107430D
Display:
Used by: IP2
Cause: Proper data's recovery setting is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430E
Display:
Used by: IP2
Cause: Proper data's carrier X position is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430F
Display:
Used by: IP2
Cause: Proper data's carrier Y position is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074310
Display:
Used by: IP2
Cause: Proper data's part pickup time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074311
Display:
Used by: IP2
Cause: Proper data's part carrier movement timer is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074312
Display:
Used by: IP2
Cause: Proper data's remover pickup timer is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074400
Display:
Used by: IP2
Cause: The SY axis and the tray is not in the safety position.
Remedy: Return the SY axis and tray to the safety position.
------------------------------
Code: 11074410
Display:
Used by: IP2
Cause: The part was not moved from the sub-nozzle to the carrier.
Remedy: Check the sub-nozzle and the carrier.
------------------------------
Code: 11074420
Display:
第 196 页
Used by:
Cause: The carrier dropped a part.
Remedy: Feed another part to the carrier.
------------------------------
Code: 11074430
Display:
Used by: IP2
Cause: Parts were not moved to the machine.
Remedy: Check the carrier.
------------------------------
Code: 11074440
Display: MTU Positioning Err
Used by: IP2
Cause: The tray movement command was not carried out correctly.
Remedy: Turn off the power at the IP2 and the MTU, and re-boot.
------------------------------
Code: 11074450
Display: MTU Error
Used by:
Cause: An error occurred at the MTU.
Remedy: Turn off the power at the IP2 and the MTU, and re-boot.
------------------------------
Code: 11075001
Display: L3 SCAN_S COM
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to start scanning resulted in an error, or a timeout
condition.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075002
Display: L3 SCAN_S PRC
Used by: IP1,IP2,IP3
Cause: A command to start scanning was sent to the L3 board, and an error was returned, or a timeout
condition occurred.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. If the error recurs, turn off
the power and start again.
------------------------------
Code: 11075003
Display: L3 SCAN_E COM
Used by: IP1,IP2,IP3
Cause: Transmission (to the L3 board) of a command to start scanning resulted in an error, or a timeout
condition. This may be due to one of the following causes: the L3 board baud rate is set below 9600
(timeout), not all the leads could be measured, or the encoder cable/sensor cable is not properly
connected.
Remedy: If the L3 board baud rate is set below 9600, set it to 9600 or greater. Check that the length of
the leads in 10.Lead_length_x and Lead_length_y in Vision_data are the same as the actual leads. Check
that the size entered in Body_size is the same as the actual body size. Make Coplanarity item 4.Y_offset
bigger so that the measurement is done farther from the tips of the leads. Check that the encoder cable is
properly connected to the CyberOptics board. Check that the sensor cable is properly connected to both
the sensor and the CyberOptics board. The cable should be connected to jumper 1. If the error recurs,
第 197 页