FUJI错误代码查询.pdf - 第395页
Display: Used by: QP242,QP201,QP202,QP203 Cause: Unit number B (SECS I/II). Specified transmission retry times were exceeded (NKS re- transmission processing counter). Remedy: Turn off the machine power. ----------------…
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (UDP/IP/ARCNET). Transmitted IP packet data did not arrive at the specified port
number.
Remedy: Turn off the machine power.
------------------------------
Code: 12031B37
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (UDP/IP/ARCNET). Transmitted packet creation time was insufficient so packet
was discarded.
Remedy: Turn off the machine power.
------------------------------
Code: 12031B38
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (UDP/IP/ARCNET). Time between placement of transmitted partitioned packets
exceeded 15 seconds (ICPM).
Remedy: Turn off the machine power.
------------------------------
Code: 12031B39
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (UDP/IP/ARCNET). Transmitted IP header includes incorrect information.
Remedy: Turn off the machine power.
------------------------------
Code: 12031B40
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (SECS I/II). T1 (character time) error.
Remedy: Turn off the machine power.
------------------------------
Code: 12031B41
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (SECS I/II). EOT waiting time exceeded T2 (protocol time).
Remedy: Turn off the machine power.
------------------------------
Code: 12031B42
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (SECS I/II). ACK waiting time exceeded T2 (protocol time).
Remedy: Turn off the machine power.
------------------------------
Code: 12031B43
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (SECS I/II). Data waiting time exceeded T2 (protocol time).
Remedy: Turn off the machine power.
------------------------------
Code: 12031B44
第 394 页
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (SECS I/II). Specified transmission retry times were exceeded (NKS re-
transmission processing counter).
Remedy: Turn off the machine power.
------------------------------
Code: 12031B45
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (SECS I/II). Buffer overflow.
Remedy: Turn off the machine power.
------------------------------
Code: 12031B46
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (SECS I/II). An inappropriate response character was received.
Remedy: Turn off the machine power.
------------------------------
Code: 12031B50
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Insufficient memory.
Remedy: Increase the available memory.
------------------------------
Code: 12031B60
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). CTS is off.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031B61
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Break code character was received.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031B63
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Framing occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031B64
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Parity error occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031B65
Display:
Used by: QP242,QP201,QP202,QP203
第 395 页
Cause: Unit number B (VM 1440). Over-run error occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031B66
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). DCD turned off during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031B72
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031B73
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031B74
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031B75
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031B76
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031B77
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031B78
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number B (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
第 396 页