FUJI错误代码查询.pdf - 第2241页
Used by: Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production program, was read and the data for the "PCCSID" item in "BLOCK", "…
production program. If a station number, slot number or device number is reported as supplementary
information, look for the part data name referred to in the device line and check it.
------------------------------
Code: 51??1641
Display: "UNIT", "PARTS" - "BLOCK", "ELDT+" format error.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and a format error was detected in "BLOCK", "ELDT+".
Remedy: Check the setting for "UNIT", "PARTS" - "BLOCK", "ELDT+" in the production program. If a
station number, slot number or device number is reported as supplementary information, look for the part
data name referred to in the device line and check it.
------------------------------
Code: 51??1642
Display: No "UNIT", "PARTS" - "BLOCK", "TRAYINF+" item definition line.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and the "BLOCK", "TRAYINF+" item definition line was not found.
Remedy: Check the setting for the item definition line for "UNIT", "PARTS" - "BLOCK", "TRAYINF+" in the
production program. If a station number, slot number or device number is reported as supplementary
information, look for the part data name referred to in the device line and check it.
------------------------------
Code: 51??1643
Display: "UNIT", "PARTS" - "BLOCK", "TRAYINF+" format error.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and a format error was detected in "BLOCK", "TRAYINF+".
Remedy: Check the setting for "UNIT", "PARTS" - "BLOCK", "TRAYINF+" in the production program. If a
station number, slot number or device number is reported as supplementary information, look for the part
data name referred to in the device line and check it.
------------------------------
Code: 51??1644
Display: "UNIT", "PARTS" - "BLOCK", "ENVDT" format error.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and a format error was detected in "BLOCK", "ENVDT".
Remedy: Check the setting for "UNIT", "PARTS" - "BLOCK", "ENVDT" in the production program. If a
station number, slot number or device number is reported as supplementary information, look for the part
data name referred to in the device line and check it.
------------------------------
Code: 51??1700
Display: No "PCCSID" item definition line.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and the "PCCSID" entry in the "BLOCK", "PRTSID+" item definition line was not found.
Remedy: Check the setting for "PCCSID" in the "UNIT", "PARTS" - "BLOCK", "PRTSID+" item definition line
in the production program. "PCCSID" is a mandatory item. If a station number, slot number or device
number is reported as supplementary information, look for the part data name referred to in the device
line and check it.
------------------------------
Code: 51??1701
Display: "PCCSID" data value is out of range.
第 2240 页
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and the data for the "PCCSID" item in "BLOCK", "PRTSID+" was out of range. When
downloading, the relevant data line is ignored.
Remedy: Check the "PCCSID" setting in "UNIT", "PARTS" - "BLOCK", "PRTSID+" in the production
program.
------------------------------
Code: 51??1702
Display: "PTPSZLQ" data is incorrect.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and the data for the "PTPSZLQ" item in "BLOCK", "PRTSID+" was out of range.
Remedy: Check the "PTPSZLQ" setting in "UNIT", "PARTS" - "BLOCK", "PRTSID+" in the production
program. The "PTPSZLQ" value should be in the range 0 ~ 160.
------------------------------
Code: 51??1703
Display: Relationship between "PTPSZLQ" and "PTPSZLI" is incorrect.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to in the device line, in the specified production
program, was read and the value for "PTPSZLQ" in "BLOCK", "PRTSID+" and the length of the "PTPSZLI"
character string did not agree.
Remedy: Check the settings for "PTPSZLI" and "PTPSZLQ" in "UNIT", "PARTS" - "BLOCK", "PRTSID+" in
the production program. When downloading, the length set at "PTPSZLQ" is taken as being valid. If
"PTPSZLI" is longer than the length set at "PTPSZLQ", the overlength data is ignored and if it is shorter, 1s
are added as padding.
------------------------------
Code: 51??1710
Display: No data record line in "UNIT", "PARTS" - "BLOCK", "ELDT+".
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and no data entry line was found in "BLOCK", "ELDT+".
Remedy: Check the settings for the data line in "UNIT", "PARTS" - "BLOCK", "ELDT+" in the production
program. When downloading, the default values for only one line are transmitted.
------------------------------
Code: 51??1711
Display: Too many data record lines in "UNIT", "PARTS" - "BLOCK", "ELDT+".
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and there were too many data record lines in "BLOCK", "ELDT+".
Remedy: Check the settings for the data line in "UNIT", "PARTS"-"BLOCK", "ELDT+" in the production
program. Only the valid number of lines is transmitted (starting from the top). Excess lines are ignored.
------------------------------
Code: 51??1720
Display: No "PCCTRY" item definition.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and the "PCCTRY" entry was not found in the "BLOCK", "TRAYINF+" item definition line.
Remedy: Check the setting for "PCCTRY" in the item definition line in "UNIT", "PARTS" - "BLOCK",
"TRAYINF+" in the production program. "PCCTRY" is a mandatory item. If a station number, slot number
or device number is reported as supplementary information, look for the part data name referred to in the
device line and check it.
第 2241 页
------------------------------
Code: 51??1721
Display: "PCCTRY" data value is out of range.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and the value for the "PCCTRY" data item in "BLOCK", "TRAYINF" was out of range.
When downloading, the relevant data line is ignored.
Remedy: Check the setting for "PCCTRY" in "UNIT", "PARTS"-"BLOCK", "TRAYINF+" in the production
program.
------------------------------
Code: 51??1722
Display: "PPCTRIF" character string length is incorrect.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and the "PPCTRIF" character length in "BLOCK", "TRAYINF+" was not correct. The
correct length for the "PPCTRIF" character string is 32 characters.
Remedy: Check the setting for "PPCTRIF" in "UNIT", "PARTS" - "BLOCK", "TRAYINF+" in the production
program. When downloading, any characters which exceed the 32 character string are ignored. If the
string is shorter than 32 characters, 1s are added as padding.
------------------------------
Code: 51??1730
Display: No machine-type "ELEMENT" in "UNIT", "PARTS" - "BLOCK", "ENVDT".
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and no "ELEMENT" record was found in "BLOCK", "ENVDT" for the applicable machine
type.
Remedy: Check the setting for "ELEMENT" in "UNIT", "PARTS" - "BLOCK", "ENVDT" in the production
program.
------------------------------
Code: 51??1731
Display: Machine-type "ELEMENT" in 'UNIT", "PARTS" - "BLOCK", "ENVDT" is multiply defined.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and there were multiple records for "ELEMENT" for the applicable machine type in
"BLOCK", "ENVDT". When downloading, the lead "ELEMENT" is valid.
Remedy: Check the setting for "ELEMENT" in "UNIT", "PARTS" - "BLOCK", "ENVDT" in the production
program.
------------------------------
Code: 51??1800
Display: No specified pallet data file.
Used by:
Cause: The specified pallet data file was not found. This report is made when the program is
downloaded, the pallet data is required in the applicable machine type and the above error is detected.
Remedy: Check the setting for the pallet data file name. Furthermore, transmit the pallet data file to the
applicable directory or create it in the applicable directory.
------------------------------
Code: 51??1801
Display: Specified pallet data file in use.
Used by:
Cause: The specified pallet data file is being used. This report is made when the program is downloaded,
the pallet data is required in the applicable machine type and the above error is detected.
第 2242 页