FUJI错误代码查询.pdf - 第1087页

------------------------------ Code: 14050002 Display: 在周期自动补正中Corner Dog的影像处理失败。 Used by: XP241,XP341,XP142,XP242 Cause: 在周期自动补正中Corner Dog的影像处理失败。 Remedy: 请用[维修保养C]->[Corner Dog调整]进行影像处理的确认。 有错误时,请确认Corner dog是否有污垢、…

100%1 / 5282
·影像取入位置不正确时,取入位置的设定有错。
请按照调整的步骤调整相机。
·闪光灯不发光时,光源有问题。
请确认布线后,进行氙气管/电源、子电路板的交换。
·相机影像不能取入时,相机有问题。
请确认布线后,进行相机、影像输入的电路板的更换。
------------------------------
Code: 1404D009
Display: 检测出吸嘴头的异物。请确认吸嘴头内是否有异物存在以及在吸嘴头内是否有不明的吸嘴存在。
Used by: XP143
Cause: 检测出吸嘴头的异物。
Remedy: 在吸嘴头内存在异物或者不明的吸嘴时请除去。
------------------------------
Code: 1404E???
Display: 1404E???
Used by:
Cause: When performing nozzle vision processing, the border between the nozzle image and the bright
background could not be found.
Remedy: Check the nozzle. Check the image acquisition conditions (especially contamination on the
nozzle and the acquisition level). Check that the nozzle diameter specified in Proper data is correct.
Check hardware such as the image camera, the board and the cables.
------------------------------
Code: 1404E000
Display: 1404E000
Used by:
Cause: The image of the nozzle could not be found when performing vision processing.
Remedy: Check the nozzle. Check the image acquisition conditions (especially contamination on the
nozzle and the acquisition level). Check that the nozzle diameter specified in Proper data is correct.
------------------------------
Code: 1404F???
Display: 1404F???
Used by:
Cause: This is a processing program logic error. Processing cannot be performed because the part data
values and the actual part dimensions are totally different.
Remedy: Check part data.
------------------------------
Code: 14050000
Display: Corner Dog影像处理出错
Used by: XP241,XP341,XP142,XP242
Cause: Corner Dog影像处理出错
Remedy: 请用[维修保养C]->[Corner Dog调整]进行影像处理的确认。
影像处理出错时,请确认Corner Dog的中心是否在搜索区域(蓝色的框)内。
在搜索区域外时,请调整到搜索区域内的位置。
请确认Corner Dog是否有污垢。
------------------------------
Code: 14050001
Display: 超过Corner Dog补正值极限。
Used by: XP241,XP341,XP242
Cause: 超出Corner Dog补正值的极限。
Remedy: 请确认Corner Dog的影像处理是否错误识别元件。
请确认Corner Dog是否有松动。
第 1086 页
------------------------------
Code: 14050002
Display: 在周期自动补正中Corner Dog的影像处理失败。
Used by: XP241,XP341,XP142,XP242
Cause: 在周期自动补正中Corner Dog的影像处理失败。
Remedy: 请用[维修保养C]->[Corner Dog调整]进行影像处理的确认。
有错误时,请确认Corner dog是否有污垢、伤痕或缺陷。
------------------------------
Code: 14050003
Display: 测定吸取位置失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 以吸取位置测定进行地供料器的送料孔的影像处理失败。
Remedy: 请确认是否安装供料器。
请确认料带导盖是否脱离。
请确认料带是否正确地装入。
------------------------------
Code: 14050004
Display: 在周期自动补正中校正尺芯片的影像处理失败。
Used by: XP141,XP142
Cause: 在周期自动补正中量规芯片的影像处理失败。
Remedy: 请确认量规芯片的污垢、尺寸。
------------------------------
Code: 14050005
Display: 在周期自动补正中玻璃校正尺的影像处理失败。
Used by: XP241,XP341,XP242
Cause: 在周期自动补正中玻璃量规的影像处理失败。
Remedy: 请确认玻璃量规的污垢、尺寸。
------------------------------
Code: 15010001
Display: Status of brd unknown
Used by: CP643
Cause: It is unclear which board production method (single board production or double board
production) is in effect.
Remedy: Use a production program that specifies a board production method.
------------------------------
Code: 15010003
Display: PCB in loader
Used by: CP643
Cause: There is a board in the conveyor system(in-conveyor,in-carrier,out-carrier,out-conveyor or main
conveyor),operation cannot be continued.
Remedy: Remove the board from the conveyor system.U
------------------------------
Code: 15010004
Display: Conv. PLC Alarm
Loader command error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,GSP5,GP2,GP3,GP551,GP6,IP3
Cause:
Remedy: Contact Fuji.
Turn the machine off,then on again.
------------------------------
Code: 15010101
第 1087 页
Display: PCB Transport Error: Prev.
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between each conveyor exceeded the preset limit. The
appropriate setting is made (1:ON 2:OFF 3:OFF). Three seconds after the deceleration point is activated
the board start point is not on, an alarm occurs and the machine is stopped.
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010102
Display: PCB Stopper Error: Prev.
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
------------------------------
Code: 15010103
Display: Command Error: Prev.
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The operator
has attempted to load a board when there is already a board. If there was a board on the conveyor the
machine attempted to load the board. If there was no board, the machine attempted to clear off the board.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
------------------------------
Code: 15010104
Display: Conv. PLC Alarm: Prev.
Used by: CP5,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not operating normally. The user cannot set this.
Remedy: Contact Fuji.
------------------------------
Code: 15010201
Display: PCB Transport Error: MCID
Chk brd conveyance at MCID
Used by: CP5,CP6,CP6M,CP65,CP642,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between the MCID conveyors exceeded the preset limit.
The appropriate removal setting between conveyors is made (1:ON 2:OFF 3:OFF).
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010202
Display: PCB Stopper Error: MCID
Used by: CP5,CP6,CP6M,CP65,CP642,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
第 1088 页