FUJI错误代码查询.pdf - 第910页
Code: 12204204 Display: Que error Used by: Cause: In the accuracy pressure control shell,the number of que which stores a command became the maximum. Remedy: Reinstall software if this error cannot be corrected after reb…
------------------------------
Code: 12204102
Display: Timeout error
Used by:
Cause: Internal function of the load cell control shell occurred.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the load cell control
shell could be damaged.
------------------------------
Code: 12204103
Display: Synchronous object error
Used by:
Cause: The synchronous object in the load cell control shell was destructed before releasing.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the load cell control
shell could be damaged.
------------------------------
Code: 12204104
Display: Que error
Used by:
Cause: In the load cell control shell,the number of que which stores a command became the maximum.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the load cell control
shell could be damaged.
------------------------------
Code: 12204200
Display: Internal function error
Used by:
Cause: In the accuracy pressure control shell,the a mapping file error or
significant digit over error occurred.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the accuracy pressure
control shell could be damaged.
------------------------------
Code: 12204201
Display: Port open error
Used by:
Cause: The accuracy pressure control shell failed in a port opening.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the accuracy pressure
control shell could be damaged.
------------------------------
Code: 12204202
Display: Timeout error
Used by:
Cause: Internal function of the accuracy pressure control shell occurred.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the accuracy pressure
control shell could be damaged.
------------------------------
Code: 12204203
Display: Synchronous object error
Used by:
Cause: The synchronous object in the accuracy pressure control shell was destructed before releasing.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the accuracy pressure
control shell could be damaged.
------------------------------
第 909 页
Code: 12204204
Display: Que error
Used by:
Cause: In the accuracy pressure control shell,the number of que which stores a command became the
maximum.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the accuracy pressure
control shell could be damaged.
------------------------------
Code: 12205001
Display: File search error
Used by:
Cause: Failed to find the board type information file. (Update shell)
Remedy: Install the file again and restart the machine.
------------------------------
Code: 12205002
Display: File search error
Used by:
Cause: Failed to find the write-control program file. (Update shell)
Remedy: Install the file again and restart the machine.
------------------------------
Code: 12205003
Display: File search error
Used by:
Cause: The file to be written to could not be found in the specified folder. (Update shell)
Remedy: Install the file again and restart the machine.
------------------------------
Code: 12205004
Display: Board error
Used by:
Cause: A board compatible with automatic updates has not been assembled, or is corrupt. (Update shell)
Remedy: Check the board connection and version, then update it manually.
Replace the board if this does not correct the problem.
------------------------------
Code: 12205005
Display: Command reply error
Used by:
Cause: The board firmware is corrupt. (Update shell)
Remedy: Update the board in question manually.
------------------------------
Code: 12205006
Display: Failed to transmit
Used by:
Cause: The data file is corrupt. (Update shell)
Remedy: Install the file again and restart the machine.
------------------------------
Code: 12205007
Display: Transmission timeout
Used by:
Cause: The data file is corrupt. (Update shell)
Remedy: Install the file again and restart the machine.
------------------------------
第 910 页
Code: 12205008
Display: Updating...
Used by:
Cause: The firmware is being updated. (Update shell)
Remedy: The firmware is being updated, do not carry out any other operations.
------------------------------
Code: 12205009
Display: The number of updates has exceeded 100.
Used by:
Cause: The number of write operations to the board has exceeded the number under which operation
can be guaranteed. (Update shell)
Remedy: Prepare a spare board because the number of write operations to the board has exceeded the
number under which operation can be guaranteed.
------------------------------
Code: 1220600a
Display: Port error
Used by:
Cause: The COM port been already open.(Radds-Shell)
Remedy: Please cancel an error.
When this error comes out frequently, Reboot the machine.
Reinstall software if this error cannot be corrected after reboot, because the Radds-Shell could be
damaged.
------------------------------
Code: 1220600b
Display: Port error
Used by:
Cause: The COM port been still not open.(Radds-Shell)
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Radds-Shell could
be damaged.
------------------------------
Code: 1220600c
Display: Port error
Used by:
Cause: Timeout occurred in the initialize statge.(Radds-Shell)
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Radds-Shell could
be damaged.
------------------------------
Code: 1220600d
Display: Port error
Used by:
Cause: Timeout occurred in the command-sending statge.(Radds-Shell)
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Radds-Shell could
be damaged.
------------------------------
Code: 1220600e
Display: Load error
Used by:
Cause: Failed to load Dll.(Radds-Shell)
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Radds-Shell could
be damaged.
------------------------------
第 911 页