FUJI错误代码查询.pdf - 第149页

Used by: GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6 Cause: The data does not match machine specifications. Remedy: Check the Proper data to ensure that the Proper data in the file is the Proper data for the machine. 1. Print out t…

100%1 / 5282
Code: 11022423
Display:
Used by: GL2
Cause: The Proper data item Middle is out of range (GL2).
Remedy: Check the Proper data item Middle.
------------------------------
Code: 11022424
Display:
Used by: GL2
Cause: The Proper data item reducing_time is out of range (GL2).
Remedy: Check the Proper data item reducing_time.
------------------------------
Code: 11022425
Display:
Used by: GL2
Cause: The Proper data item acceleration_time is out of range (GL2).
Remedy: Check the Proper data item acceleration_time.
------------------------------
Code: 11022426
Display:
Used by: GL2
Cause: The Proper data item start_offset is out of range (GL2).
Remedy: Check the Proper data item start_offset.
------------------------------
Code: 11022427
Display:
Used by: GL2
Cause: The Proper data item zero_reducingX, Y, Q is out of range (GL2).
Remedy: Check the Proper data item zero_reducingX, Y, Q.
------------------------------
Code: 11022428
Display:
Used by: GL2
Cause: The Proper data item zero_reducing Z1, Z2 is out of range (GL2).
Remedy: Check the Proper data item zero_reducing Z1, Z2.
------------------------------
Code: 11022429
Display:
Used by: GL2
Cause: The Proper data item Spot_up_end_height is out of range (GL2).
Remedy: Check the Proper data item Spot_up_end_height.
------------------------------
Code: 11022430
Display: Proper
Used by: GL2
Cause: The ascending speed of the Z axis exceeds the range allowable in the machine specifications.
Remedy: Check the Proper data items Spot_up_speed 1, 2 and Max_speed_Z1, Z2 to ensure that the value
entered does not exceed the hexadecimal number 7AA. Max_speed_Z1, Z2 is set at 6AA when at 100%.
------------------------------
Code: 11022500
Display:
第 148 页
Used by: GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6
Cause: The data does not match machine specifications.
Remedy: Check the Proper data to ensure that the Proper data in the file is the Proper data for the
machine.
1. Print out the Proper, and after inputting new Proper, transmit this to the machine.
2. Check that the machines registered in the MCS line descriptor are correct.
3. Check that the channel to which the data line cable is connected is correct.
------------------------------
Code: 11022501
Display:
Used by:
Cause: The Proper data item max.speed_? is out of range (GSP2).
Remedy: Check the Proper data item max.speed_?. The acceptable range is from 0% to 100%. Re-
transmit after changing Proper data.
------------------------------
Code: 11022502
Display:
Used by:
Cause: The Proper data item Middle_? is out of range (GSP2).
Remedy: Check the Proper data item Middle_?. The acceptable range is from 5 pulses to 500 pulses. Re-
transmit after changing Proper data.
------------------------------
Code: 11022503
Display:
Used by:
Cause: The Proper data item Reducing_time_? is out of range (GSP2).
Remedy: Check the Proper data item Reducing_time_?. The acceptable range is from 30 msec to 500
msec. Re-transmit after changing Proper data.
------------------------------
Code: 11022504
Display:
Used by:
Cause: The Proper data item Acceleration_time_? is out of range (GSP2).
Remedy: Check the Proper data item Acceleration_time_?. The acceptable range is from 30 msec to 500
msec. Re-transmit after changing Proper data.
------------------------------
Code: 11022505
Display:
Used by:
Cause: The Proper data item Start_offset_? is out of range (GSP2).
Remedy: Check the Proper data item Start_offset_?. The acceptable range is from 0% to 100%. Re-
transmit after changing Proper data.
------------------------------
Code: 11022506
Display:
Used by:
Cause: The Proper data item Zero_reducing_? is out of range (GSP2).
Remedy: Check the Proper data item Zero_reducing_?. The acceptable range is from 100 pulses to 600
pulses. Re-transmit after changing Proper data.
------------------------------
Code: 11022510
第 149 页
Display:
Used by: GSP5
Cause: Proper data was set to automatically supply solder for a machine which cannot automatically
supply solder (GSP5).
Remedy: Check Proper data.
------------------------------
Code: 11022511
Display:
Used by: GSP5
Cause: Proper data was set to use stockers on a machine which cannot use stockers (GSP5).
Remedy: Check Proper data.
------------------------------
Code: 11022512
Display:
Used by: GSP5
Cause: The cleaning count status is illegal.
Remedy: Check cleaning_count_status in Proper data.
------------------------------
Code: 11022513
Display:
Used by: GSP5
Cause: The universal count status is illegal.
Remedy: Check universal_count_status in Proper data.
------------------------------
Code: 11022514
Display:
Used by: GSP5,GP551,GP6
Cause: The solder count status is illegal.
Remedy: Check solder_count_status in Proper data.
------------------------------
Code: 11022515
Display:
Used by: GSP5
Cause: The manual cleaning count status is illegal.
Remedy: Check manual_cleaning_count_status in Proper data.
------------------------------
Code: 11022516
Display:
Used by: GSP5,GP551,GP6
Cause: The mark read count cleaning count status is illegal.
Remedy: Check mark_read_count_status in Proper data.
------------------------------
Code: 11022517
Display: 11022517
Used by: GSP5
Cause: The stocker's communication port is not correct.The communication board on the stocker to
which the transmission has been made is malfunctioning.
Remedy: After correctly setting the communication port, retransmit the data.After correctly setting the
communication board, re-transmit the data.
------------------------------
Code: 11022518
第 150 页