Remedy: The magazine number must be between 1 and 4. Check the production program. ------------------------------ Code: 11010206 Display: Used by: QP242,QP201,QP202,QP203 Cause: An inappropriate device number has been sp…
Code: 11010124
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 4 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010125
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 4 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010126
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 5 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010201
Display: Program NG 0010
Used by: IP1,QP242,QP201,QP202,QP203
Cause: A next device error occurred during program device check.
Remedy: Check the displayed device data and the next device data.
------------------------------
Code: 11010202
Display: Program NG 0012
Used by: IP1,QP242,QP201,QP202,QP203
Cause: During program device check, a device number that could not be used by the machine was found.
Remedy: Check the displayed device data and next device data numbers.
------------------------------
Code: 11010203
Display:
Used by: IP2,QP242,QP201,QP202,QP203
Cause: The current production program calls for feeders to be placed in a device where there is a tape
pack feeder. The tape pack feeder takes up 11 device positions, so there must be 5 free devices on each
side of the reference device number.
Remedy: Check the production program.
------------------------------
Code: 11010204
Display:
Used by: QP242,QP201,QP202,QP203
Cause: An inappropriate unit number has been specified for the tape pack feeder.
Remedy: The unit number must be between 1 and 4. Check the production program.
------------------------------
Code: 11010205
Display:
Used by: QP242,QP201,QP202,QP203
Cause: An inappropriate magazine number has been specified for the tape pack feeder.
第 5 页
Remedy: The magazine number must be between 1 and 4. Check the production program.
------------------------------
Code: 11010206
Display:
Used by: QP242,QP201,QP202,QP203
Cause: An inappropriate device number has been specified for the tape pack feeder.
Remedy: The device number must be between 1 and 37 or 51 and 87.
Check the production program.
------------------------------
Code: 11010207
Display:
Used by: QP242,QP201,QP202,QP203
Cause: An inappropriate reference device number has been specified for the tape pack feeder.
Remedy: The reference device number must be between 5 and 33, or 55 and 83.
Check the production program.
------------------------------
Code: 11010208
Display: Head number setting error
Used by: NP133,NP134,NP153
Cause: There is an error in the head numbers specified in sequence data.
Remedy: If head specifications are not made, all sequences should be set to "0". When head specifications
are required, a head number (1-16) should be set for every sequence.
------------------------------
Code: 11010301
Display: "PDG device_type ERROR D**" (IP)
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The Part data indicating device type specifies either a tape feeder when a tray is being used, or a
tray when a tape feeder is being used.
The value replacing the "**" in the display is the device number.
Remedy: Correct the device type specification in the Part data. Set a value from 0 to 9 for Part data "35.
device type (MCS/1)", "3.
Package_type (MCS/2)" if a tray is being used, or a value other than 0 to 9 for Part data for "61. device
type (IP) (MCS/1)", "3.
Package_type (MCS/2)" if a tape feeder is being used. Refer to the MCS/2 Programming Manual for the
meanings of these values.
------------------------------
Code: 11010302
Display: "Can't use this device" (IP)
Used by: QP242,QP201,QP202,QP203
Cause: This error occurs when a device number from D111 to D120 is specified for an FIP machine
without an left tray, or when a device number from D101 to D110 is specified for an FIP machine withouta
right tray.
Remedy: Check the device numbers.
------------------------------
Code: 11010303
Display: "VF Data Er 0001 D No.***"
Used by: QP242,QP201,QP202,QP203
Cause: The resistance or capacity value for the indicated device includes two periods. The value replacing
the "***" in the display is the device number.
Remedy: Check the resistance and capacity values for the indicated device.
------------------------------
第 6 页
Code: 11010304
Display: VF Data Er 0002 D No. ***
Used by: QP242,QP201,QP202,QP203
Cause: Index number is out of designated range.
Remedy: Check device number ***.
------------------------------
Code: 11010305
Display: VF Data Er 0003 D No. ****
Used by: QP242,QP201,QP202,QP203
Cause: A character specifying part type is not part of the set of permissible characters.
Remedy: Check Device data No. ****.
------------------------------
Code: 11010306
Display: VF Data Er 0004 D No.***
Used by: QP242,QP201,QP202,QP203
Cause: When setting the authorized numerical range, setting was made outside the allowable limits.
Remedy: Check the device data for device number ***.
------------------------------
Code: 11010307
Display: VF Data Er 0005 D No. ***
Used by: QP242,QP201,QP202,QP203
Cause: When setting the authorized numerical range, setting was made outside the allowable limits.
Remedy: Check the device data at device number ***.
------------------------------
Code: 11010308
Display: VF Data Er 0006 D No. ***
Used by: QP242,QP201,QP202,QP203
Cause: Part category F is out of range.
Remedy: Check the F data item in device number ***.
------------------------------
Code: 11010309
Display: VF Data Er 0007 D No. ***
Used by: QP242,QP201,QP202,QP203
Cause: Part category H is out of range.
Remedy: Check the H data item in device number ***.
------------------------------
Code: 1101030A
Display: VF Data Er 0008 D No. ***
Used by: QP242,QP201,QP202,QP203
Cause: Part category R is out of range.
Remedy: Check the R data item in device number ***.
------------------------------
Code: 1101030B
Display: VF Data Er 0009 D No. ***
Used by: QP242,QP201,QP202,QP203
Cause: There is no final "/" (slash).
Remedy: Check the F data item in device number ***.
------------------------------
Code: 1101030C
Display: Error: Nozzle No.
Used by: IP2,QP242,QP201,QP202,QP203