FUJI错误代码查询.pdf - 第230页
Remedy: Download an uncorrupted program file and select it using the [Program] command. ------------------------------ Code: 11100116 Display: Production program data mismatch. Used by: NP2,QP3 Cause: Pre-allocation sequ…
Used by: NP2,QP3
Cause: Device data and feeder data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010E
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Feeder and part data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 1110010F
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Part number data and part shape data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100110
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Part number data and part packaging data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100111
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Sequence and feeder data are not consistent.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100112
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Fiducial marks are missing from the program.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100113
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Block skip marks are missing from the program.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100114
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: The mark sequence being referred to by a mark does not exist.
Either the mark is referring itself or a mark that is read in a later sequence.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100115
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Mark sequences that are referenced by the placing sequences are missing from the program.
第 229 页
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100116
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: Pre-allocation sequence order error!
Remedy: Revise the Place Before sequence order and reload the program using the change program
command.
------------------------------
Code: 11100117
Display: Parts camera not installed!
Used by: NP2,QP3
Cause: The camera types displayed in the parameter section are not installed on the machine.
Remedy: Download an uncorrupted program file and select it using the [Program] command.
------------------------------
Code: 11100118
Display: Production program data mismatch.
Used by: NP2,QP3
Cause: A frontlight setting has been specified for a CCD camera.
Remedy: Specify a backlight setting for the CCD camera.
------------------------------
Code: 11100119
Display: MCTYPE error
Used by: NP2,QP3
Cause: The MCTYPE settings in the program are not suitable for this machine.
Remedy: Specify a different production program.
------------------------------
Code: 1110011A
Display: Production program error.
Used by: NP2,QP3
Cause: There is a problem with the program. Refer to the parameters.
Remedy: Specify a different program.
------------------------------
Code: 1110011B
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The board has not stopped at the correct position due to incorrect conveyance, deceleration, or
acceleration speeds, or incorrect distance between the deceleration and arrival sensors.
Remedy: Either reduce the conveyance speed, or increase the speed of acceleration/deceleration.
Alternatively, increase the distance between the deceleration and arrival sensors.
------------------------------
Code: 1110011C
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The board has not stopped at the correct position due to incorrect speed of
acceleration/deceleration (+G160).
Remedy: Reduce the deceleration speed, or increase the acceleration speed.
------------------------------
Code: 1110011D
Display: Production program check alarm
Used by: NP2,QP3
第 230 页
Cause: Data exists in production program for side that has no part supply position.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 1110011E
Display: Production program check alarm
Used by: NP2,QP3
Cause: Specified cavity number exceeds the tray dimensions.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 1110011F
Display: Production program check alarm
Used by: NP2,QP3
Cause: Invalid data for pin check mode exists.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100120
Display: Production program check alarm
Used by: NP2,QP3
Cause: Light setting for pin check mode is incorrect.
If "Cut" is specified : Do not use frontlight.
If "Mark" or "Bump" is specified : Do not use backlight.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100121
Display: Simultaneous mark reading error
Used by: NP-2, QP-3
Cause: Simultaneous reading of unsuitable marks was specified in the production program. Marks
should be read one at a time.
Remedy: Change the settings in the program. Mark sequences within the parameter area cannot be read
simultaneously.
------------------------------
Code: 11100122
Display: Production program check alarm
Used by: NP2,QP3
Cause: Tape feed pitch is not set to (a) motor feeder.
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100124
Display: Production program check alarm
Used by: QP3
Cause: Although the CCGA Mark Check item has been set to YES(1), the Pin Check Mode has not been
set to MARK(5) or BUMP(6).
Remedy: Execute program change command after downloading correct production program.
------------------------------
Code: 11100125
Display: Production program check alarm
Used by: QP3
Cause: The feeder type has not been set to "Tray" for the STU.
Remedy: Only trays can be supplied to STUs. When using an STU, the feeder type must be set to "Tray".
When not using an STU, specify an appropriate feeder type.
------------------------------