Cause: Parts cannot be picked. Remedy: Replenish the part supply. ------------------------------ Code: 1D040010 Display: Used by: Cause: The Y length is too short. Remedy: Check the part length. -------------------------…
data.
------------------------------
Code: 1D03C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D03C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D03C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D03D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D03D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D03E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D03F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D040002
Display:
Used by:
第 1273 页
Cause: Parts cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D040010
Display:
Used by:
Cause: The Y length is too short.
Remedy: Check the part length.
------------------------------
Code: 1D040011
Display:
Used by:
Cause: The part length in the Y direction is too long.
Remedy: Check the part length.
------------------------------
Code: 1D040012
Display:
Used by:
Cause: The pitch between leads is too narrow (by more than 20%).
Remedy: Check the part shape.
------------------------------
Code: 1D040013
Display:
Used by:
Cause: The pitch between leads is too wide (by more than 20%).
Remedy: Check the part shape.
------------------------------
Code: 1D040014
Display:
Used by:
Cause: There are too many leads.
Remedy: Check the part shape.
------------------------------
Code: 1D040015
Display:
Used by:
Cause: The pitch between leads is too narrow (by more than 20%).
Remedy: Check the part shape.
------------------------------
Code: 1D040016
Display:
Used by:
Cause: The pitch between leads is too wide (by more than 20%).
Remedy: Check the part shape.
------------------------------
Code: 1D040017
Display:
Used by:
Cause: There are too many leads.
Remedy: Check the part shape.
------------------------------
第 1274 页
Code: 1D040018
Display:
Used by:
Cause: There is too much part slippage at the pickup point.
Remedy: Check pickup conditions.
------------------------------
Code: 1D040019
Display:
Used by:
Cause: There is too much part slippage at the pickup point.
Remedy: Check pickup conditions.
------------------------------
Code: 1D04001A
Display:
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D04001B
Display:
Used by:
Cause: There are too many leads (set in PDG).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D04001C
Display:
Used by:
Cause: There are too many leads (set in PDG).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D040020
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D040021
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D040022
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.
第 1275 页