FUJI错误代码查询.pdf - 第1188页

Used by: Cause: The lead pitch is much narrower than the value entered in Part data. Remedy: Enter the correct value in Part data. ------------------------------ Code: 1CA00004 Display: 1CA00004 Used by: Cause: A lead is…

100%1 / 5282
Used by:
Cause: The image was not acquired by the line scan camera. The movement of the part being vision
processed stopped during image acquisition.
Remedy: Machine operation halted while the image was being acquired. Rectify the cause of this
stoppage and then carry out vision processing again.
------------------------------
Code: 1C680004
Display: 1C680004
Used by:
Cause: The image was not acquired by the line scan camera. The movement of the part being vision
processed stopped during image acquisition.
Remedy: Machine operation halted while the image was being acquired. Rectify the cause of this
stoppage and then carry out vision processing again.
------------------------------
Code: 1C680005
Display: 1C680005
Used by:
Cause: Image acquisition failed.
Remedy: An image could not be acquired from the line scan camera. The machine was disabled while
acquiring the image. Correct the problem, then repeat the operation.
------------------------------
Code: 1C680006
Display: 1C680006
Used by:
Cause: Image acquisition failed.
Remedy: An image could not be acquired from the line scan camera. The specified acquisition area
(range) may be too large. Specify a smaller acquisition area.
------------------------------
Code: 1C680FFF
Display: 1C680FFF
Used by:
Cause: Image acquisition failed.
Remedy: An image could not be acquired from the line scan camera. An unexpected error occurred while
acquiring the image.
------------------------------
Code: 1CA00001
Display: 1CA00001
Used by:
Cause: Parts are not being picked up.
Remedy: Check that the parts feeder is in place and that the parts have not run out. Also check that the
nozzle being used can pick up the parts.
------------------------------
Code: 1CA00002
Display: 1CA00002
Used by:
Cause: The size of the part is excessively different from the size set in part data.
Remedy: Check that the correct part size is registered in part data. If the size difference is large, increase
the tolerance values.
------------------------------
Code: 1CA00003
Display:
第 1187 页
Used by:
Cause: The lead pitch is much narrower than the value entered in Part data.
Remedy: Enter the correct value in Part data.
------------------------------
Code: 1CA00004
Display: 1CA00004
Used by:
Cause: A lead is bent.
Remedy: A lead is bent in excess of the tolerance set in Pitch_limit in part data.
------------------------------
Code: 1CA00005
Display: 1CA00005
Used by:
Cause: There is not enough contrast between the part and its background for vision processing.
Remedy: Check the fluorescent plate on the nozzle sticker and the condition of the lighting system.
------------------------------
Code: 1CA00006
Display: 1CA00006
Used by:
Cause: Part data has not been registered.
Remedy: Failed to register part data. Check if part data and vision type setting are correct. If part data is
correct, the vision system may be faulty. Contact Fuji.
------------------------------
Code: 1CA00007
Display: 1CA00007
Used by:
Cause: The resolution is incorrect.
Remedy: The resolution is set to "0" or lower. Check Proper data.
------------------------------
Code: 1CA00008
Display: 1CA00008
Used by:
Cause: The nozzle center is incorrect.
Remedy: The nozzle center is outside the permissible range. Check Proper data.
------------------------------
Code: 1CA00009
Display: 1CA00009
Used by:
Cause: Nozzle data is incorrect.
Remedy: The nozzle type or backlight type is incorrect, or the nozzle size is set to zero or less. Check
Nozzle data.
------------------------------
Code: 1CA0000A
Display: 1CA0000A
Used by:
Cause: The direction setting is incorrect.
Remedy: The direction setting can be set between 1 and 8. Check the setting.
------------------------------
Code: 1CA0000B
Display: 1CA0000B
Used by:
第 1188 页
Cause: The part size is larger than the backlight size.
Remedy: Check the part and backlight sizes.
------------------------------
Code: 1CA00F04
Display: 1CA00F04
Used by:
Cause: A Vision_type setting was specified that does not exist in part data.
Remedy: Verify what types of vision types in part data can be utilized with the vision processing software
that is currently being used. In the case that part data is correct then there was a failure with the
initialization of the vision processing system during startup. If this error occurs contact Fuji.
------------------------------
Code: 1CA??001
Display: 1CA??001
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that the part is larger than the diameter of the specified
background disk. If "??" equals 64, 78, 79, 7B, 7C, 96, 97, 98, 99or A0 then the part data description is
incorrect.
If "??" equal FC then the part is smaller than the specified nozzle size.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, 17, 18, or 28 then the production program should be
corrected so that a nozzle is employed that uses a background disk which is larger than the one currently
being used. If "??" equals 64, 78, 79, 7B, 7C, 96, 97, 98, 99or A0 this error will occur when the part is
being registered in the vision processing system. Vision processing can in fact be executed in this case,
however, the results cannot be guaranteed. Inspect the part data. If "??" equal FC then the part could not
be found because it is smaller than the specified nozzle size. Check for errors in the nozzle data.
------------------------------
Code: 1CA??002
Display: 1CA??002
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that the part is smaller than the specified nozzle diameter.
If "??" equals 1E, 64, 78, 79, 7B, 7C, 96, 97, 98, 99, A0, AC, B4, F0, F1 or F2 then the part data
description is incorrect. If "??" equal FC then contour tracing cannot begin due to a bent nozzle.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, 17, 18, or 28 then the part is smaller than the specified
nozzle diameter and the part in question cannot be recognized. Make sure the nozzle data is correct. If
"??" equals 1E, 64, 78, 79, 7B, 7C, 96, 97, 98, 99, A0, AC, B4, F0, F1 or F2 this error will occur when the
part is being registered in the vision processing system. Vision processing cannot be executed. Inspect
the part data. If "??" equal FC then the nozzle's rotational center is not aligned with the nozzle image.
Check for a bent nozzle.
------------------------------
Code: 1CA??003
Display: 1CA??003
Used by:
Cause: The Vision_type in part data is expressed using hexadecimal notation ("??"). If "??" equals 0A, 0B,
0C, 0D, 14, 15, 16, 17, 18, or 28 this signifies that there is an error in the part data. If "??" equal FC then
the part's X-direction size exceeds the tolerance value.
Remedy: If "??" equals 0A, 0B, 0C, 0D, 14, 15, 16, or 17 the description in Bodysize in part data is
incorrect. Make the necessary corrections to this data item in part data. If "??" equals 18 or 28 the
description of the part in part data is incorrect. Make the necessary corrections in part data. If "??" equal
FC then the part size is incorrect. Correct the part data.
------------------------------
第 1189 页