Code: 11100A02 Display: Revision file error! Used by: NP2,QP3 Cause: The revision of the camera definition file is too old. Cannot use the camera(s). Remedy: Download or reinstall as correct camera definition file and re…

100%1 / 5282
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle station specifications file.
Remedy: Download an uncorrupted nozzle station specifications file, reboot the machine and load the
settings using the [Update] command.
------------------------------
Code: 11100903
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The nozzle station data items displayed in the parameter section are outside the prescribed range.
All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100904
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle station specifications
file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100905
Display: Nozzle station inconsistency error!
Used by: NP2,QP3
Cause: The nozzle station spec. names displayed in the parameter section are listed in the nozzle station
settings file, but are missing from the nozzle station specifications file.
Remedy: Download compatible nozzle station settings and specification files, reboot the machine and load
the settings using the [Update] command.
------------------------------
Code: 11100906
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: CCIMF file format error in nest specifications file. All nozzle data has been cleared from memory.
Remedy: Download a normal nest specifications file, then start up the machine. Use the nozzle memory
change command to re-register the nozzles.
------------------------------
Code: 11100907
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle station specifications for this machine are not included in the nozzle station specification
file. All nozzle settings have been cleared.
Remedy: Download a compatible nozzle station specification file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100A01
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open camera definition file. Cannot use the camera(s).
Remedy: Download or reinstall an uncorrupted camera definition file and restart the machine.
------------------------------
第 243 页
Code: 11100A02
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the camera definition file is too old. Cannot use the camera(s).
Remedy: Download or reinstall as correct camera definition file and restart the machine.
------------------------------
Code: 11100A03
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the camera definition file is too new. Cannot use the camera(s).
Remedy: Download or reinstall a correct camera definition file and restart the machine.
------------------------------
Code: 11100A04
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the camera definition file.
Remedy: Download or reinstall a correct camera definition file and restart the machine.
------------------------------
Code: 11100A05
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The camera definition data items displayed in the parameter section are outside the prescribed
range. Cannot use the camera(s).
Remedy: Download or reinstall an uncorrupted camera definition file and restart the machine.
------------------------------
Code: 11100A06
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the camera definition file.
Remedy: Download or reinstall a correct camera definition file and restart the machine.
------------------------------
Code: 11100A07
Display: Camera definition file error
Used by: NP2,QP3
Cause: A camera definition file error occurred. Cameras cannot be used at this time.
Remedy: Re-install a normal camera definition file, then start up the machine.
------------------------------
Code: 11100B01
Display: File-open error!
Used by: NP2,QP3
Cause: Nozzle Proper data file could not be opened. Either file does not exist or it is damaged.
Remedy: Download correct nozzle proper data file or reinstall and then reboot machine.
------------------------------
Code: 11100B02
Display: File save error!
Used by: NP2,QP3
Cause: Nozzle Proper data file could not be written to hard disk. Save of nozzel Proper data has failed.
Remedy: Inspect the hard disk.
------------------------------
Code: 11100B03
Display: File creation error!
第 244 页
Used by: NP2,QP3
Cause: Nozzle Proper data file could not be created. Save of nozzel Proper data has failed.
Remedy: Inspect the hard disk.
------------------------------
Code: 11100B04
Display: Nozzle Proper data file alarm
Used by: NP2,QP3
Cause: Error in nozzle Proper data file.
Remedy: Reinstall correct nozzle Proper data file and reboot machine.
------------------------------
Code: 11100B05
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: Nozzle Proper data file could not be opened. Either file does not exist or it is damaged.
Remedy: Download or reinstall a correct nozzle proper data file and restart the machine.
------------------------------
Code: 11100C01
Display: File-open error!
Used by: NP2,QP3
Cause: Error in auto calibration data file.
Remedy: Download correct auto calibration data file and reboot machine.
------------------------------
Code: 11100C02
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the auto calibration data file.
Remedy: Download or reinstall a correct auto calibration data file and restart the machine.
------------------------------
Code: 11100D01
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open mark camera file. Cannot use the mark camera(s).
Remedy: Download or reinstall an uncorrupted mark camera file and restart the machine.
------------------------------
Code: 11100D02
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the mark camera file.
Remedy: Download or reinstall a correct mark camera file and restart the machine.
------------------------------
Code: 11100D03
Display: Mark camera file error
Used by: NP2,QP3
Cause: A mark camera file error occurred. Cameras cannot be used at this time.
Remedy: Re-install a normal mark camera file, then start up the machine.
------------------------------
Code: 11208003
Display: <XP*41>料带宽度在规格以外或者是 0。
(元件号码 = "*****")
<XP*42>Tape Width在规格之外。不能决定所使用的供料器。
Used by: XP241,XP341,XP142,XP242