Display: Used by: IP2 Cause: The Proper data item Reducing time Y is less than 30 or greater than 500 (IP2). Remedy: Enter the correct Proper value and re-transmit the Proper data. ------------------------------ Code: 11…
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022619
Display:
Used by: IP2
Cause: Error conveyor is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261A
Display:
Used by: IP2
Cause: Error Box X, Y is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261B
Display:
Used by: IP2
Cause: Y loading pos. is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261C
Display:
Used by: IP2
Cause: The Proper data item Acceleration time X is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261D
Display:
Used by: IP2
Cause: The Proper data item Acceleration time Y is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261E
Display:
Used by: IP2
Cause: The Proper data item Acceleration time Z is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102261F
Display:
Used by: IP2
Cause: The Proper data item Acceleration time Q is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022620
Display:
Used by: IP2
Cause: The Proper data item Reducing time X is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022621
第 156 页
Display:
Used by: IP2
Cause: The Proper data item Reducing time Y is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022622
Display:
Used by: IP2
Cause: The Proper data item Reducing time Z is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022623
Display:
Used by: IP2
Cause: The Proper data item Reducing time Q is less than 30 or greater than 500 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022624
Display: ATC POSITION ERROR
Used by: IP2
Cause: The Proper value 64.X_atc_origin_2 is smaller than 35.X_atc_origin (setting was not made).
Remedy: Make the Proper measurement and enter it. This displays only on the IP1 with shift type
nozzles.
------------------------------
Code: 11022630
Display:
Used by: IP2
Cause: Proper data's X_max is smaller than the values X1_ESC and X2_ESC.
Remedy: Input the correct Proper values.
------------------------------
Code: 11022631
Display:
Used by: IP2
Cause: Proper data's X_max is smaller than the values X1_wait and X2_wait.
Remedy: Input the correct Proper values.
------------------------------
Code: 11022632
Display:
Used by: IP2
Cause: Proper data's X_max is smaller than the values Nozzle_check_pos.1 and Nozzle_check_pos.2.
Remedy: Input the correct Proper values.
------------------------------
Code: 11022633
Display: None
Used by: IP2,IP3
Cause: When using the placing pressure control function, the 6 channel communication board port
number is the same as another port number. Alternatively, the port number (from 11 to 30) is out of
range (FIP3).
Remedy: Change the communication port number (Pressure control port no.) in Proper data (FIP3).
------------------------------
Code: 11022634
第 157 页
Display:
Used by: IP2,IP3
Cause: The value set in Proper Data item "Flux_st1_d_no" or "Flux_st2_d_no" is out of range.
Remedy: The valid range for these Proper Data items is 0 to 37 ("0" signifies that it is not used). After
correcting the Proper Data item in question, transmit the production program again.
------------------------------
Code: 11022635
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H2.X" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 2, the nozzle inclination is found using
the "nozzle_size_H2.X" and "nozzle_size_H2.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022636
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H3.X" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 3, the nozzle inclination is found using
the "nozzle_size_H3.X" and "nozzle_size_H3.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022637
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H2.Y" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 2, the nozzle inclination is found using
the "nozzle_size_H2.X" and "nozzle_size_H2.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022638
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_H3.Y" parameter in the IP2 Proper
data is set to 0. (When a rectangular nozzle is used with Holder 3, the nozzle inclination is found using
the "nozzle_size_H3.X" and "nozzle_size_H3.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.
------------------------------
Code: 11022639
Display: Same as code
Used by: IP2
Cause: Vision processing cannot be performed when the "nozzle_size_1.Y" parameter in the IP2 Proper
data (i.e., the Y value for Nozzle 1 of the nozzle station) is set to 0. (When a rectangular nozzle is used as
Nozzle 1 of a nozzle station with a variable holder, the nozzle inclination is found using the
"nozzle_size_1.X" and "nozzle_size_1.Y" settings. Vision processing cannot be performed to find the
rectangular nozzle inclination when one of these nozzle size values has not been input.)
Remedy: Enter the correct nozzle size and retransmit the Proper data.