FUJI错误代码查询.pdf - 第178页

Cause: abolished Remedy: abolished ------------------------------ Code: 11025?06 Display: abolished Used by: QP132 Cause: abolished Remedy: abolished ------------------------------ Code: 11025?07 Display: abolished Used …

100%1 / 5282
Cause: The ICM panel confirmation time setting is incorrect.
Remedy: Ensure that the "ICM Board Check Timer" item in Proper data is set to the default (0), or to a
value of 10 or more.
------------------------------
Code: 11022A40
Display: Same as the code
Used by: QP242
Cause: The ICM loader time-out setting is incorrect.
Remedy: Ensure that the "ICM Loader Wait Timer" item in Proper data is set to the default (0), or to a
value of 15 or more.
------------------------------
Code: 11022A41
Display: Same as the code
Used by: QP132
Cause: A setup of Proper data(2408:Camera2 Vacuum On Timing [msec]) is not right.
Remedy: Please check a setup of Proper data(2408:Camera2 Vacuum On Timing [msec]).
------------------------------
Code: 11022B00
Display: 因为不能读取上一次关机时所保存的固有值,读取了再上一次关机时所保存的固有值。
进行固有值的确认,必要时请进行再测定和再设定。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 因为不能读取上一次关机时所保存的固有值,读取了再上一次关机时所保存的固有值。
Remedy: 进行固有值的确认,必要时请重新进行测定和设定。
------------------------------
Code: 11025?02
Display: Same as Code.
Used by: QP132
Cause: The PMC's program placement origin X coordinate is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Program Origin X0" to the correct value. This Proper data item exists
for each module. Module one is number 697 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?03
Display: Same as Code.
Used by: QP132
Cause: The PMC's program placement origin Y coordinate is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Program Origin Y0" to the correct value. This Proper data item exists
for each module. Module one is number 698 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?04
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?05
Display: abolished
Used by: QP132
第 177 页
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?06
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?07
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?08
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?09
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference pick-up position X is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Device Origin D0_X" to the correct value. This Proper data item exists
for each module. Module one is number 719 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0A
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference pick-up position Y is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Device Origin D0_Y" to the correct value. This Proper data item exists
for each module. Module one is number 720 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0B
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference parts eject position X is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Parts Eject Pos_X" to the correct value. This Proper data item exists
for each module. Module one is number 721 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0C
Display: Same as Code.
Used by: QP132
第 178 页
Cause: The PMC's reference parts eject position Y is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Parts Eject Pos_Y" to the correct value. This Proper data item exists
for each module. Module one is number 722 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0D
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?0E
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?0F
Display: Same as Code.
Used by: QP132
Cause: The PMC's Y-axis retract position is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Escape Pos Y" to the correct value. This Proper data item exists for
each module. Module one is number 724 in Proper data. Thereafter, add (PMC No. -1) times 82 to locate
this item for each module.
------------------------------
Code: 11025?10
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?11
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?12
Display: Same as Code.
Used by: QP132
Cause: The PMC's X-axis extended position is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Max Limit Position X" to the correct value. This Proper data item
exists for each module. Module one is number 728 in Proper data. Thereafter, add (PMC No. -1) times 82
to locate this item for each module.
------------------------------
Code: 11025?13
Display: 11025?13
Used by:
第 179 页