and contact Fuji if this error occurs multiple times. ------------------------------ Code: 1CFF5005 Display: 1CFF5005 Used by: Cause: Failed to generate the "calibration object". Remedy: This error occurs if a …

100%1 / 5282
Display: 1CFF0037
Used by:
Cause: Failed to save image.
Remedy: There may be insufficient disk space. Verify there is enough free disk space available.
------------------------------
Code: 1CFF0038
Display: 1CFF0038
Used by:
Cause: An error occurred during vision processing.
Remedy: An error occurred during vision processing. This is not a common error.There could be a
problem with the vision processing system. Restart the system and continue production. If this error
occurs repeatedly, please save the image, obtain trace data, and contact Fuji.
------------------------------
Code: 1CFF010C
Display: 1CFF010C
Used by:
Cause: IC mark check and cut check were not registered.
Remedy: The machine can not register these checks, if it is using an old version of vision
processing.Change the part data so that the first pin check is not carried out. Or use the new version
(V2.42 or later).
------------------------------
Code: 1CFF5001
Display: 1CFF5001
Used by:
Cause: Failed to generate the "acquire object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5002
Display: 1CFF5002
Used by:
Cause: Failed to set the "acquire object" CCD camera properties.
Remedy: This error occurs if these settings are attempted before "acquire object" is generated. This is not
a common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5003
Display: 1CFF5003
Used by:
Cause: Failed to set the "acquire object" LS camera properties.
Remedy: This error occurs if these settings are attempted before "acquire object" is generated. This is not
a common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5004
Display: 1CFF5004
Used by:
Cause: Failed to set the "acquire object" utility settings.
Remedy: This error occurs if these settings are attempted before "acquire object" is generated. This is not
a common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
第 1218 页
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5005
Display: 1CFF5005
Used by:
Cause: Failed to generate the "calibration object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5006
Display: 1CFF5006
Used by:
Cause: Failed to generate the "part object".
Remedy: This error occurs if a re-registration is attempted without deleting the object, or when "part
object" generation is attempted before the "calibration object" has been registered. This is not a common
error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data and contact
Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5008
Display: 1CFF5008
Used by:
Cause: Failed to register direction check data.
Remedy: This error occurs if a function is executed before generating the "parts object". This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5009
Display: 1CFF5009
Used by:
Cause: Failed to delete the "acquire object".
Remedy: This error occurs if an "acquire object" deletion is attempted before the "acquire object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500A
Display: 1CFF500A
Used by:
Cause: Failed to delete the "part object".
Remedy: This error occurs if an "part object" deletion is attempted before the "part object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500B
Display: 1CFF500B
Used by:
Cause: Failed to delete the "calibration object".
Remedy: This error occurs if an "calibration object" deletion is attempted before the "calibration object"
has been registered. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
第 1219 页
Code: 1CFF500C
Display: 1CFF500C
Used by:
Cause: Failed to delete the "nozzle object".
Remedy: This error occurs if an "nozzle object" deletion is attempted before the "nozzle object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500D
Display: 1CFF500D
Used by:
Cause: Failed to delete the "fiducial object".
Remedy: This error occurs if an "fiducial object" deletion is attempted before the "fiducial object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500E
Display: 1CFF500E
Used by:
Cause: Failed to generate the "fiducial object".
Remedy: This error occurs if a re-registration is attempted without deleting the object, or when "part
object" generation is attempted before the "calibration object" has been registered. This is not a common
error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data and contact
Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500F
Display: 1CFF500F
Used by:
Cause: Failed to generate the " nozzle object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5010
Display: 1CFF5010
Used by:
Cause: Failed to generate the "nozzle inspection object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5011
Display: 1CFF5011
Used by:
Cause: Failed to set the nozzle offset.
Remedy: This error occurs if an attempt is made to specify the nozzle offset before the "nozzle object" has
been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5012
Display: 1CFF5012