FUJI错误代码查询.pdf - 第1143页
Cause: Remedy: ------------------------------ Code: 15040449 Display: Used by: Cause: Remedy: ------------------------------ Code: 1504044A Display: Used by: Cause: Remedy: ------------------------------ Code: 1504044B D…
Used by: XP143,XP243
Cause: OUT搬运轨道升降台的上升失败。
Remedy: OUT搬运轨道升降台未上升时,请确认通过OUT升降台的配管是否脱离
上升时,请确认以下传感器是否正常地动作。
<XP143>
·OUT搬运轨道升降台的上升确认传感器(X026:OutStLftUpChk)
<XP243>
·OUT搬运轨道升降台的上升确认传感器1(X040:OutStLftUpChk1)
·OUT搬运轨道升降台的上升确认传感器2(X041:OutStLftUpChk2)
------------------------------
Code: 15040443
Display: OUT搬运轨道的升降台下降失败。
Used by: XP143,XP243
Cause: OUT搬运轨道的升降台下降失败。
Remedy: OUT搬运轨道的升降台未下降时,请确认通过OUT搬运轨道的升降台的配管是否脱离。
下降时,请确认以下的传感器是否正常地动作。
<XP143>
·OUT搬运轨道升降台的上升确认传感器(X026:OutStLftUpChk)
<XP243>
·OUT搬运轨道升降台的上升确认传感器1(X040:OutStLftUpChk1)
·OUT搬运轨道升降台的上升确认传感器2(X041:OutStLftUpChk2)
------------------------------
Code: 15040444
Display: 电路板位置异常 送出侧
Used by: GPX
Cause: 在送出侧搬运轨道无法搬运的位置上存在电路板。
Remedy: 请除去电路板。
<img src="$LKEY_ERRIMG_MC$/EI0009.bmp">
------------------------------
Code: 15040445
Display: 载出搬运轨道有电路板错误
Used by: NXTP
Cause: 因为在载出搬运轨道上有电路板,所以不进入到下一步的处理。
Remedy: 请清除电路板。
<img src="$LKEY_ERRIMG_MC$/15040445.PNG">
------------------------------
Code: 15040446
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040447
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040448
Display:
Used by:
第 1142 页
Cause:
Remedy:
------------------------------
Code: 15040449
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1504044A
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1504044B
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1504044C
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1504044D
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040500
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040501
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040502
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
第 1143 页
Code: 15040503
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040505
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040506
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040507
Display: CANNOT GET PCB DATA
Loader error: 15040507
Used by: QP132
Cause: The board data area could not be saved.
Remedy: Carry out the unload operation and the flush out operation in succession and then restart.
------------------------------
Code: 15040508
Display: PCB_AVAILABLE_NG_TUP
LD_ERR 15040508
Used by:
Cause: In the case of SMEMA compatibility, a board unload prohibition signal from the previous process
is preventing unloading from taking place.
Remedy: Check the status of the signal line connection from the previous process.
------------------------------
Code: 15040509
Display: IN INTERLOCK PLT ARRIVED OFF
LD_ERR 15040509
Used by:
Cause: The pallet on the production conveyor popped off the loader.
Remedy: Return the pallet to the loader or slide the pallet onto the production conveyor. Check the
operation of the loading pallet-arrival-check 1 sensor.
------------------------------
Code: 1504050A
Display: IN INTERLOCK PLT PASSED ON
Used by: QP132
Cause: The return conveyor pallet popped up onto the loader.
Remedy: Set the pallet on the loader or return it to the return conveyor. Check the operation of the
loading pallet-arrival-check 2 sensor.
------------------------------
Code: 1504050B
Display: IN INTERLOCK PCB CLAMP ON
LD_ERR 1504050B
第 1144 页