------------------------------ Code: 21006060 Display: env command fork error Used by: Cause: The env command could not be started up. Remedy: Re-execute the function. If it still doesn't work, re-boot MCS. --------…

100%1 / 5282
Remedy: If there are special sequences in the program, re-boot MCS.
------------------------------
Code: 21006058
Display: special sequence work file write error
Used by:
Cause: Data could not be written to the temporary file for special sequences.
Remedy: If there are special sequences in the program, re-boot MCS.
------------------------------
Code: 21006059
Display: special sequence work file create error
Used by:
Cause: A special sequence temporary file could not be created.
Remedy: If there are special sequences in the program, re-boot MCS.
------------------------------
Code: 2100605A
Display: file open error
Used by:
Cause: Unable to open the input file.
Remedy: Check the filename or the file contents.
------------------------------
Code: 2100605B
Display: file read error
Used by:
Cause: A file could not be read.
Remedy: Check the file and save it.
------------------------------
Code: 2100605C
Display: file write error
Used by:
Cause: A file could not be written to.
Remedy: Check that there are no write protect settings in effect. Otherwise, check the hard disk to ensure
that there is enough memory available. If not, eliminate unnecessary files or perform maintenance on the
hard disk.
------------------------------
Code: 2100605D
Display: generator command fork error
Used by:
Cause: The glue program generator could not be booted up.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 2100605E
Display: ls command fork error
Used by:
Cause: The ls command could not be booted.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 2100605F
Display: err_disp command fork error
Used by:
Cause: The error displays could not be booted.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
第 1898 页
------------------------------
Code: 21006060
Display: env command fork error
Used by:
Cause: The env command could not be started up.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 21006061
Display: help command fork error
Used by:
Cause: The HELP functions could not be booted.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 21006062
Display: separator pipe read error
Used by:
Cause: The Separator pipe could not be read.
Remedy: Re-execute the function.
------------------------------
Code: 21006063
Display: same device comment, but differing part names found
Used by:
Cause: Different part names were found with the same device comment.
Remedy: Correct the device comments in the Part Data.
------------------------------
Code: 21006064
Display: no eligible machines exist for separation
Used by:
Cause: The machine cannot be processed by the Separator.
Remedy: Correct the Line and/or Off-line Descriptor.
------------------------------
Code: 21006065
Display: No use device.
Used by:
Cause: Unused device.
Remedy: This is a warning message. Processing continues.
------------------------------
Code: 21006066
Display: exp command fork error
Used by:
Cause: The exp command could not be used.
Remedy: Re-install the automatic programming software.
------------------------------
Code: 21006067
Display: exp command error exit
Used by:
Cause: The exp command was exited.
Remedy: Re-install the automatic programming software.
------------------------------
Code: 21006068
Display: reason file open error
第 1899 页
Used by:
Cause: The separator's reason file could not be opened.
Remedy: Check that the file exists, and check that the write protect setting is not on.
------------------------------
Code: 21006069
Display: reason file print out error
Used by:
Cause: The separator's reason file could not be printed out.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 2100606A
Display: reason file read error
Used by:
Cause: The separator's reason file could not be read.
Remedy: Check that the file exists, and check that the write protect setting is not on.
------------------------------
Code: 2100606B
Display: parameter file open error
Used by:
Cause: The separator's parameter status file could not be opened.
Remedy: The file does not exist. Pull a new file from the editor.
------------------------------
Code: 2100606C
Display: illegal parameter file
Used by:
Cause: The separator's parameter status file is illegal.
Remedy: Re-install the automatic programming software.
------------------------------
Code: 2100606D
Display: parameter file open error
Used by:
Cause: The separator's parameter status file could not be opened.
Remedy: The file does not exist. Pull a new file from the editor.
------------------------------
Code: 2100606E
Display: PT file not found <**.**.pt>
Used by:
Cause: Either a processing line in the permanent set table or an entire machine's PT file was not found.
Remedy: This is a warning message. Continue operation when questioned by the machine.
------------------------------
Code: 2100606F
Display: cartridge empty
Used by:
Cause: The feeder specified in the special conditions file was already used. Details are written to the
UN_sep file.
Remedy: Check the contents of the special condition file.
------------------------------
Code: 21006070
Display: no separation
Used by:
Cause: A condition which prohibits separation has been set in the special conditions file.