FUJI错误代码查询.pdf - 第903页

Cause: Association was suspended because a feeder was removed. Remedy: Reset the feeder on the device (PFU etc.). ------------------------------ Code: 12202010 Display: Parameter error. Used by: Cause: DxShell was set an…

100%1 / 5282
Cause: The conveyor shell could not start normally .
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201020
Display: Failed to terminate dll.
Used by:
Cause: The conveyor shell could not terminate normally.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201028
Display: Abnormal parameter.
Used by:
Cause: Because the parameter when using an API was an incorrect, the function could not be executed.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201032
Display: Communication port error.
Used by:
Cause: Conveyor control function wasn't possible to do the opening or the closing of the communication
port.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201033
Display: Que error.
Used by:
Cause: The Que in conveyor control function was full.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12202001
Display: Device communication error.
Used by:
Cause: The received data is incorrect data.
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12202002
Display: Queue buffer full.
Used by:
Cause: DxShell API function is called by mistake.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202003
Display: Association Suspended.
Used by:
第 902 页
Cause: Association was suspended because a feeder was removed.
Remedy: Reset the feeder on the device (PFU etc.).
------------------------------
Code: 12202010
Display: Parameter error.
Used by:
Cause: DxShell was set an invalid parameter.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202011
Display: No data.
Used by:
Cause: It was not possible to get data from DxShell.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202020
Display: Device communication error.
Used by:
Cause: The time-out interval elapsed, and the response data did not receive.
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12202021
Display: Device communication error.
Used by:
Cause: It was not possible to do writing in Device communication port
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12203001
Display: Invalid Command
Used by:
Cause: The stepping motor controller detected an invalid command.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203002
Display: Axis error
Used by:
Cause: The stepping motor controller detected a command to a axis
that is unused.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203003
Display: Syntax error
Used by:
第 903 页
Cause: The Syntax error occurred in the stepping motor controller.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203004
Display: Link error
Used by:
Cause: The link communication error occurred in the stepping motor controller.
Remedy: The cause is possible that the noise from outside or
that the power has been turned on and off during communication.
Reboot the machine.
------------------------------
Code: 12203005
Display: Check sum error
Used by:
Cause: The Check sum error occurred in the stepping motor controller.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203006
Display: Break signal error
Used by:
Cause: The stepping motor shell received the break signal.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 1220300A
Display: Multiple open
Used by:
Cause: The Stepping-Motor-Shell been already opened.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300B
Display: Port error
Used by:
Cause: The Stepping-Motor-Shell is not still opend.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300C
Display: Initialize error
Used by:
Cause: Initialization of the shell did not end within a prescribed time.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the Stepping-Motor-
Shell could be damaged.
------------------------------
Code: 1220300D
Display: Timeout
Used by:
Cause: There is no response from a controller after transmitting a command.
第 904 页