Display: Used by: Cause: A level surface cannot be found. The tilt of the part was too large. Remedy: Check the shape of the part. Check that the part is being picked properly. ------------------------------ Code: 1D0300…
------------------------------
Code: 1D030010
Display: 0016
Used by:
Cause: The part is too short in the Y direction.
Remedy: Check that the nozzle is not dirty, that there are no foreign particles on the part, and that the
correct part is being analyzed.
------------------------------
Code: 1D030011
Display: 0017
Used by:
Cause: The part is too long in the Y direction.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030012
Display: 0018
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030013
Display: 0019
Used by:
Cause: The part shape is not what was expected. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030014
Display: 0020
Used by:
Cause: The upper right hand corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030015
Display: 0021
Used by:
Cause: The lower right hand corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D030016
Display:
Used by:
Cause: The upper area lead cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030017
Display:
Used by:
Cause: The lower area lead cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030080
第 1264 页
Display:
Used by:
Cause: A level surface cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030081
Display:
Used by:
Cause: A level surface cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030082
Display:
Used by:
Cause: A level surface cannot be found. The tilt of the part was too large.
Remedy: Check the shape of the part. Check that the part is being picked properly.
------------------------------
Code: 1D030083
Display:
Used by:
Cause: A correct image cannot be taken. The upper and lower parts of the part are too uneven. There is
foreign matter on the part.
Remedy: Check the camera, vision processing board, cable and focus. Remove foreign matter from the
part.
------------------------------
Code: 1D038002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D038100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D038110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D038111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
第 1265 页
Code: 1D038112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D038113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D038114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D038115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D038120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D038121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D038122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D038123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D0382??
Display:
Used by: