Display: 1CFF0037 Used by: Cause: Failed to save image. Remedy: There may be insufficient disk space. Verify there is enough free disk space available. ------------------------------ Code: 1CFF0038 Display: 1CFF0038 Used…

100%1 / 5282
Remedy: This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF0030
Display: 1CFF0030
Used by:
Cause: Execution of an unsupported command was attempted.
Remedy: The ID of the attempted command was in the UlSubCode. This is not a common error. There
could be a visionsystem abnormality. Restart the system. Obtain the trace data and contact Fuji if this
error occurs multiple times.
------------------------------
Code: 1CFF0032
Display: 1CFF0032
Used by:
Cause: The connection port number for the line-scan camera is not correct.
Remedy: A value "6" or less has been set for the connection port number.Line-scan cameras must be a
value "7" or greater.An incorrect camera ID is entered for the "ulSubCode".
------------------------------
Code: 1CFF0033
Display: 1CFF0033
Used by:
Cause: Failed to send VP execute command.
Remedy: A function error was returned while attempting to send the VP execute command. The vision
command ID specified in the ulSubcode is output. This is a rarely occurring error. There could be a
problem with the vision system. Cut and then resupply power to the machine. If this does not rectify the
problem, contact Fuji. Obtain a trace report.
------------------------------
Code: 1CFF0034
Display: 1CFF0034
Used by:
Cause: VP execute command timeout error.
Remedy: The vision processing execute command was not received within the specified time. The vision
command ID specified in the ulSubcode is output. This error should not normally occur as the VA time
out period is unlimited. There could be a problem with the vision system. Cut and then resupply power to
the machine. If this does not rectify the problem, contact Fuji. Obtain a trace report.
------------------------------
Code: 1CFF0035
Display: 1CFF0035
Used by:
Cause: Error occurred while waiting for VP result.
Remedy: An error was returned while attempting the VP result response. There could be a problem with
the vision system. Cut and then resupply power to the machine. If this does not rectify the problem,
contact Fuji. Obtain a trace report.
------------------------------
Code: 1CFF0036
Display: 1CFF0036
Used by:
Cause: Image file could not be opened.
Remedy: Verify that the folder used for storing image files exists.
------------------------------
Code: 1CFF0037
第 1217 页
Display: 1CFF0037
Used by:
Cause: Failed to save image.
Remedy: There may be insufficient disk space. Verify there is enough free disk space available.
------------------------------
Code: 1CFF0038
Display: 1CFF0038
Used by:
Cause: An error occurred during vision processing.
Remedy: An error occurred during vision processing. This is not a common error.There could be a
problem with the vision processing system. Restart the system and continue production. If this error
occurs repeatedly, please save the image, obtain trace data, and contact Fuji.
------------------------------
Code: 1CFF010C
Display: 1CFF010C
Used by:
Cause: IC mark check and cut check were not registered.
Remedy: The machine can not register these checks, if it is using an old version of vision
processing.Change the part data so that the first pin check is not carried out. Or use the new version
(V2.42 or later).
------------------------------
Code: 1CFF5001
Display: 1CFF5001
Used by:
Cause: Failed to generate the "acquire object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5002
Display: 1CFF5002
Used by:
Cause: Failed to set the "acquire object" CCD camera properties.
Remedy: This error occurs if these settings are attempted before "acquire object" is generated. This is not
a common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5003
Display: 1CFF5003
Used by:
Cause: Failed to set the "acquire object" LS camera properties.
Remedy: This error occurs if these settings are attempted before "acquire object" is generated. This is not
a common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5004
Display: 1CFF5004
Used by:
Cause: Failed to set the "acquire object" utility settings.
Remedy: This error occurs if these settings are attempted before "acquire object" is generated. This is not
a common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
第 1218 页
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5005
Display: 1CFF5005
Used by:
Cause: Failed to generate the "calibration object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5006
Display: 1CFF5006
Used by:
Cause: Failed to generate the "part object".
Remedy: This error occurs if a re-registration is attempted without deleting the object, or when "part
object" generation is attempted before the "calibration object" has been registered. This is not a common
error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data and contact
Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5008
Display: 1CFF5008
Used by:
Cause: Failed to register direction check data.
Remedy: This error occurs if a function is executed before generating the "parts object". This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5009
Display: 1CFF5009
Used by:
Cause: Failed to delete the "acquire object".
Remedy: This error occurs if an "acquire object" deletion is attempted before the "acquire object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500A
Display: 1CFF500A
Used by:
Cause: Failed to delete the "part object".
Remedy: This error occurs if an "part object" deletion is attempted before the "part object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500B
Display: 1CFF500B
Used by:
Cause: Failed to delete the "calibration object".
Remedy: This error occurs if an "calibration object" deletion is attempted before the "calibration object"
has been registered. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------