FUJI错误代码查询.pdf - 第471页

number of times specified. D** indicates the device number. Remedy: Check the feeder. ------------------------------ Code: 12040404 Display: Same as code Used by: CP4-1,CP4-2,CP4-3,CP65,CP642,CP643 Cause: The results of …

100%1 / 5282
level setting or the nozzle diameter setting in the Proper data may be incorrect. Check the values of these
settings.
Check the setting condition of the power feeders. Check for alien matter between the mechanical and
electrical contacts.(NP2,QP3)
------------------------------
Code: 12040304
Display: Part pick-up confirmation error!
Used by: QP3,NP1
Cause: Failed to pick up the part.
Remedy: Check the condition of the feeders.
------------------------------
Code: 12040305
Display:
Used by: CP7
Cause: It was impossible for parts to pick that occurred the no-parts.
Remedy: Please try doing the device-check.
------------------------------
Code: 12040306
Display: 吸件失败。
Used by: XP241,XP341
Cause: 吸取元件失败。
Remedy: 请确认是否料尽。
吸取元件时,请确认吸嘴是否吸到元件。
请用IO检查,确认在吸住元件的状态下X015处于ON。
------------------------------
Code: 12040401
Display: "Pickup error" (CP5)
Used by: CP4-1,CP4-2,CP4-3,CP5
Cause: A sensor check of a small component has indicated that the nozzle is not holding a component
even though there are components in the tape feeder.
Remedy: Check for deterioration in the manner in which the component is picked up. If necessary, adjust
the component check sensor.
------------------------------
Code: 12040402
Display: "CHECK TAPE FEEDER" (CP3), "D*** pickup error" (CP4), "Can't process
D***" (CP5), "Check D***" (CP6). The value replacing the "***" is the device number.
Used by: CP3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The 1st robot was unable to pickup a large component (on the CP3). Otherwise, a sensor check
of a large component has indicated that the nozzle is not holding a component even though there are
components in the tape feeder.
Remedy: Check for deterioration in the manner in which the component is picked up. If necessary, adjust
the component check sensor. On the CP3, inspect the tape feeder and the component pickup check
sensor on the 1st robot. On the CP6, check the manner in which the component is picked up and
determine whether the device offset values are appropriate.
------------------------------
Code: 12040403
Display: RELOAD PARTS(CP3) Check D**(CP4)
Check Tape Feeder PM??:D**(QP)
Used by: CP3,CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: When an attempt was made to inspect a part which was too small to be checked by the sensor,
there was no part on the nozzle even though there are parts in the feeder. Recovery was attempted the
第 470 页
number of times specified. D** indicates the device number.
Remedy: Check the feeder.
------------------------------
Code: 12040404
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP65,CP642,CP643
Cause: The results of component vision processing indicate a compensation amount exceeding [p/m]30
mm ([p/m]3 mm for the CP6) in the X direction.
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.
------------------------------
Code: 12040405
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP652C,CP642,CP643
Cause: The results of component vision processing indicate a compensation amount exceeding 30 mm
([p/m]3 mm for the CP6) in the Y direction.
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.
------------------------------
Code: 12040406
Display: Same as code (CP6)
Used by: CP4-1,CP4-2,CP4-3,CP652C,CP642,CP643
Cause: An abnormality in communication with the vision processor has occurred during vision
processing.
Remedy: Turn off the machine, then restart it. Contact Fuji if this error occurs frequently.
------------------------------
Code: 12040407
Display: Same as code
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The results of component vision processing indicate a compensation amount exceeding 30 mm in
the Q direction.
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.
------------------------------
Code: 12040408
Display: Same as code
Used by: IP1
Cause: In the case of a tape feeder on the IP1, a subrobot nozzle pickup error has occurred. The
subrobot nozzle has failed to pick up a component.
Remedy: Have the machine try to pick up the component again. Inspect the tape feeder.
------------------------------
Code: 12040409
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,NP132,NP133
Cause: The amount of offset in the X direction between the body center and the nozzle center specified in
the part data item, "Pickup_x" in "Tolerance_information" has been exceeded.
Remedy: Check the way the part is picked up or check the validity of the device offset value.
------------------------------
Code: 1204040A
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,NP132,NP133
第 471 页
Cause: The amount of offset in the Y direction between the body center and the nozzle center specified in
the part data item, "Pickup_x" in "Tolerance_information" has been exceeded.
Remedy: Check the way the part is picked up.
------------------------------
Code: 1204040B
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,NP132,NP133
Cause: The amount of offset in the Q direction between the body center and the nozzle center specified in
the part data item, "Pickup_x" in "Tolerance_information" has been exceeded.
Remedy: Check the way the part is picked up.
------------------------------
Code: 1204040C
Display: Feeder Indexing Error
Used by: CP-8Series
Cause: Unable to pick-up the part due to a feeder indexing error.
Remedy: Adjust the indexing pitch.
If the indexing pitch is correct, there may be a problem with the nozzle.
The nozzle may be bent not allowing the NY-axis to correct within the movable range, or the nozzle
bend has changed since last measurement and has not been compensated.
Recheck the nozzle bend and replace any excessively bent nozzles.
------------------------------
Code: 12040410
Display: Tombstoning condition detected.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The detected part height is different from the height specified in Part data.
Remedy: Check to see if the part has been picked up properly. A tombstoning pickup condition may also
have occurred.
------------------------------
Code: 12040411
Display: 吸取位置公差错误
Used by: XP142,XP242
Cause: 元件的中心位置相对于吸嘴中心的偏移量超过公差值。
Remedy: 请检查元件的吸取状态以及供料器的状态。
没有发生吸取位置偏移时请执行以下的指令,重新测定吸嘴的中心位置。
·[生产]-[吸嘴编辑]-[尺寸检查]指令
·或者 XP-142E 的[生产]-[测定吸嘴中心]-[测定吸嘴中心开始]指令
------------------------------
Code: 12040412
Display: 吸取角度公差错误
Used by: XP142,XP242
Cause: 旋转方向的偏移量超过公差值。
Remedy: 请检查元件的吸取状态以及供料器的状态。
------------------------------
Code: 12040413
Display: 吸取了元件的反面。
Used by: XP142,XP242
Cause: 吸取了元件的反面。
Remedy: 请确认是否吸取了元件的反面。
吸取了元件的反面时,吸取状态有可能变坏。
请调查吸取高度、吸取位置、供料器的状态是否变坏。
请进行吸嘴中心的重新测定。
第 472 页