Remedy: This is not an error message. It is a warning. It does not constitute a problem. ------------------------------ Code: 12031F7E Display: Used by: QP242,QP201,QP202,QP203 Cause: Unit number F (VM 1440). Communicati…

100%1 / 5282
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F76
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F77
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F78
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F79
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7A
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7B
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7C
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F7D
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
第 428 页
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F7E
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F7F
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F80
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F88
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F89
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F8A
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F8B
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12033001
Display: IMAGE SENSOR IS BUSY
IMAGE SENSOR BUSY ERROR
Used by: IP1,IP2
Cause: The image sensor board was previously in operation, so the image could not be taken.
Remedy: Check the image sensor board on the VME rack. Take note of the data displayed.
------------------------------
第 429 页
Code: 12033002
Display: IMAGE SENSOR IS NO GOOD
IMAGE SENSOR COMP ERROR
Used by: IP1,IP2
Cause: The signal to take an image is not coming out of the image sensor board.
Remedy: Check the connectors on the VME rack's image sensor board. This error message sometimes
occurs when the placing point is lower than coordinate point X0 on the X axis. Check the sequence
coordinates. Take note of the data displayed.
------------------------------
Code: 12034101
Display: PLC Link Alarm (cp6)
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The remote I/O board is not ready.
Remedy: Reboot the machine. If the problem persists contact Fuji.
------------------------------
Code: 12034102
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The remote I/O board circuit is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034104
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The OP link is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034108
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Remote I/O alarm.
Remedy: None.
------------------------------
Code: 12034110
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: An interrupt was not received from the remote I/O board.
Remedy: Check the mother board interrupt jumper.
------------------------------
Code: 12034120
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Failed in remote I/O board (1st board) initialization.
Remedy: Reboot the machine.
------------------------------
Code: 12034201
Display:
Used by:
Cause: The remote I/O board is not ready.
Remedy: Change the board.
------------------------------