FUJI错误代码查询.pdf - 第299页
Display: Used by: Cause: An FCS error occurred in the transmit data, causing an abort error. Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM version and the machine vers…
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. CPU unit alarm. Cancel the alarm. Perform the I/O command again.
------------------------------
Code: 12020520
Display:
Used by:
Cause: Remote not recognized, double usage of channel.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. Check that the remote I/O channels are set correctly.
------------------------------
Code: 12020521
Display:
Used by:
Cause: The stocker sequencer could not operate due to an alarm in the CPU. Turn off the stocker power
and reboot.
Remedy:
------------------------------
Code: 12020522
Display:
Used by:
Cause: The appropriate memory unit does not exist.
Remedy: Turn off the stocker sequencer CPU power, and then check the memory.
------------------------------
Code: 12020523
Display:
Used by:
Cause: The memory is protected.
Remedy: Turn off the protect memory switch at the stocker.
------------------------------
Code: 120205A0
Display:
Used by:
Cause: A parity error occurred in the transmit data, causing an abort error.
Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM
version and the machine version, and contact Fuji.
------------------------------
Code: 120205A1
Display:
Used by:
Cause: A framing error occurred in the transmit data, causing an abort error.
Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM
version and the machine version, and contact Fuji.
------------------------------
Code: 120205A2
Display:
Used by:
Cause: An overrun error occurred in the transmit data, causing an abort error.
Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM
version and the machine version, and contact Fuji.
------------------------------
Code: 120205A3
第 298 页
Display:
Used by:
Cause: An FCS error occurred in the transmit data, causing an abort error.
Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM
version and the machine version, and contact Fuji.
------------------------------
Code: 120205A4
Display:
Used by:
Cause: A format error occurred in the transmit data, causing an abort error.
Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM
version and the machine version, and contact Fuji.
------------------------------
Code: 120205A5
Display:
Used by:
Cause: An address error occurred in the transmit data, causing an abort error.
Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM
version and the machine version, and contact Fuji.
------------------------------
Code: 120205A8
Display:
Used by:
Cause: A maximum frame length error occurred in the transmit data, causing an abort error.
Remedy: This is probably caused by noise. If this problem occurs frequently, check the stocker ROM
version and the machine version, and contact Fuji.
------------------------------
Code: 120205B0
Display:
Used by:
Cause: The program area is not 16 kilobytes so execution cannot be carried out.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. The extension DM can only be used when the program area is 16 kilobytes.
------------------------------
Code: 12020601
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12020602
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12020603
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
第 299 页
------------------------------
Code: 12020604
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12020605
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12020606
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12020607
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12020608
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 12020609
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1202060A
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1202060B
Display: Abolished
Used by: QP122
Cause: Abolished
Remedy: Abolished
------------------------------
Code: 1202060C
Display: Abolished
第 300 页