FUJI错误代码查询.pdf - 第1078页
Code: 14011003 Display: 在周期自动补正中用于测定基准定位点的影像处理失败。 Used by: XP141,XP241,XP341,XP142,XP242 Cause: 在周期自动补正中用于测定基准定位点的影像处理失败。 Remedy: 请确认基准定位点是否有污垢。 ------------------------------ Code: 14011004 Display: 基准定位点产生1mm以上的偏差。请重新测…
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The slope of the mark in the Y direction exceeds +-10% of Size_b.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010062
Display: err0062
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The width at the top (Size_b) exceeds the tolerance range (more than +-10%).
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010063
Display: err0063
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The width on the right side (Size_b) exceeds the tolerance range (more than +-10%).
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010064
Display: err0064
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: If the fiducial mark is a cross mark, the width at the top and the bottom (dimension b) exceeds
the tolerance range ( more than +-10 %). Alternatively, operation was stopped by an interrupt command.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010065
Display: err0065
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The width on the left side (Size_b) exceeds the tolerance range (more than +-10%).
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14011000
Display: 读取基准定位点出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 读取基准定位点出错。
Remedy: 请确认是否输入正确的定位点数据。
请确认生产程序上的坐标与实际定位点位置的坐标是否一致。
基准定位点上有污垢存在时请除去。
------------------------------
Code: 14011001
Display: 在范围检查中超过范围公差值。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在范围检查中超过范围公差值。
Remedy: 请确认生产程序上的坐标与实际定位点位置的坐标是否一致。
在读取基准定位点时存在着错误识别的可能性。
------------------------------
Code: 14011002
Display: 在间距检查中超过间距公差值。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在间距检查中超过间距公差值。
Remedy: 请确认生产程序上的坐标与实际定位点位置的坐标是否一致。
在读取基准定位点时存在着错误识别的可能性。
------------------------------
第 1077 页
Code: 14011003
Display: 在周期自动补正中用于测定基准定位点的影像处理失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在周期自动补正中用于测定基准定位点的影像处理失败。
Remedy: 请确认基准定位点是否有污垢。
------------------------------
Code: 14011004
Display: 基准定位点产生1mm以上的偏差。请重新测定基准定位点。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 基准定位点的固有值或原点有可能偏移。
Remedy: 请重新测定基准定位点,或重新测定原点。
------------------------------
Code: 14011005
Display: 基准定位点的影像处理失败。
Used by: XP142,XP242
Cause: 基准定位点的影像处理失败。
Remedy: 请确认基准定位点是否有污垢。请确认基准定位点的固有值。
------------------------------
Code: 14011006
Display: 不能发现高精度料盘基准定位点。
Used by: XP242
Cause: 读取的料盘为高精度料盘时,定位点有污垢或距基准位置的偏移太大。
读取的料盘为标准料盘时,高精度料盘确认传感器的调整不良。
Remedy: 高精度料盘时,请确认定位点是否有污垢。。
请消除往复臂的错位。
标准料盘时,请调整高精度料盘确认传感器(X045)。
------------------------------
Code: 14011007
Display: 基准定位点的识别角度超过了容许值。
Used by: XP142,XP242
Cause: 基准定位点的识别角度超过了容许值。
Remedy: 请确认电路板的角度。
请确认基准定位点的模板。
------------------------------
Code: 14011008
Display: 单料盘基准定位点的影像处理失败。
Used by: XP142
Cause: 单料盘上的基准定位点的影像处理失败。
Remedy: 请确认是否安装了单料盘。
请确认在固有值中基准定位点的位置是否被正确地设定。
请确认定位点是否有污垢。
------------------------------
Code: 14011009
Display: 微型料盘基准定位点的影像处理失败。
Used by: XP142
Cause: 微型料盘专用托架上的基准定位点的影像处理失败。
Remedy: 请确认是否安装了微型料盘专用托架。
请确认基准定位点是否有污垢。
------------------------------
Code: 14030001
Display: er0001
第 1078 页
Used by: GL2,GL5
Cause: The color of the first search point is the color specified in GL2 Glue Black0 or White1, but the
edge of the glue dot could not be found.
Remedy: If the glue dot application is not stable, adjust the application pressure, application time, lower
position timer, lower position height, etc. If the application is stable, check that the vision processing
system is taking the image correctly. If it isnlt, check the CCD level and the GL2 Glue Black0 or Whitel
setting. Refer to the FCP-II Operation Manual for further details.
------------------------------
Code: 14030002
Display: er0002
Used by: GL2,GL5
Cause: The color of the first search point is not the color specified in GL2 Glue Black0 or White1, but the
edge of the glue dot could not be found.
Remedy: If the glue dot application is not stable, adjust the application pressure, application time, lower
position timer, lower position height, etc. If the application is stable, check that the vision processing
system is taking the image correctly. If it isnlt, check the CCD level and the GL2 Glue Black0 or Whitel
setting. Refer to the FCP-II Operation Manual for further details.
------------------------------
Code: 14030003
Display: er0003
Used by: GL2,GL5
Cause: The size of the glue dot is too big for the edge to be detected.
Remedy: If the glue dot application is not stable, adjust the application pressure, application time, lower
position timer, lower position height, etc. If the application is stable, check that the vision processing
system is taking the image correctly. If it isnlt, check the CCD level and the GL2 Glue Black0 or Whitel
setting. Refer to the FCP-II Operation Manual for further details.
------------------------------
Code: 14030004
Display: er0004
Used by:
Cause: Noise was discovered, or neighboring dots are too close to distinguish between them.
Remedy: If the application is stable, check that the vision processing system is taking the image correctly.
If it isn't, check the CCD level and the GL2 Glue Black0 or Whitel setting. Refer to the FCP-II Operation
Manual for further details.
------------------------------
Code: 14030005
Display: er0005
Used by: GL2,GL5,GL541,(QP3)
Cause: The glue application point is too large.
Remedy: If the application amount is unstable, stabilize it by adjusting parameters such as the
application pressure, the application time(the Apply Volume), the lower limit timer, and the lower limit
height. If glueapplication is normal, make sure that the image is scanned correctly. If the image is not
scanned correctly, check the CCD level and the "GL2 Glue Black0 or White1" parameter in the program's
headerdata(check the CCD level and the "Mark Color" parameter in the program). (For details, see
Chapter 3, "Automatic operation and programming" and Chapter 2, "Glue checking" in t e FGL-2
Operation Manual.)
------------------------------
Code: 14030006
Display: er0006
Used by: GL2,GL5,GL541,(QP3)
Cause: The glue application point is too small.
第 1079 页