FUJI错误代码查询.pdf - 第827页

Cause: A command was issued to the LLL incorrectly. Or the LLL did not respond correctly. ? is the module number. "****" is the error code.(QP2) Y-axis measurement command processing error.A command was issued …

100%1 / 5282
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Either return the current tray to the magazine using the [POSITION] command or remove the
tray manually.
------------------------------
Code: 1207E?43
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray positioning sensor NG" (QP2)
Used by: QP242
Cause: The tray height positioning sensor for the tray that has been pulled has been executed but the
sensor will not turn ON or the sensor is already ON.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the state of the tray height positioning sensor.
------------------------------
Code: 1207E?44
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"X-axis measurement command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The LLL board may be carrying out another command. ? is the module number. "****" is the
error code.(QP2)
X-axis measurement command error.The LLL board may be carrying out another
command.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?45
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"X-axis measurement command processing error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP201,NP2,QP3
Cause: A command was issued to the LLL incorrectly. Or the LLL did not respond correctly. ? is the
module number. "****" is the error code.(QP2)
X-axis measurement command processing error. A command was issued to the LLL incorrectly. Or
the LLL did not respond correctly.(NP2,QP3)
Remedy: Check that the LLL board and the LLL sensor are connected correctly.(QP2,NP2,QP3)
------------------------------
Code: 1207E?46
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Y-axis measurement command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP201,NP2,QP3
Cause: The LLL board may be carrying out another command. ? is the module number. "****" is the
error code.(QP2)
Y-axis measurement command error. The LLL board may be carrying out another
command.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?47
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Y-axis measurement command processing error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
第 826 页
Cause: A command was issued to the LLL incorrectly. Or the LLL did not respond correctly. ? is the
module number. "****" is the error code.(QP2)
Y-axis measurement command processing error.A command was issued to the LLL incorrectly. Or
the LLL did not respond correctly.(NP2,QP3)
Remedy: Check that the LLL board and the LLL sensor are connected correctly.
------------------------------
Code: 1207E?48
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Measurement completion command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Another command may currently be executing. ? is the module number. "****" is the error
code.(QP2)
Y-axis measurement command processing error.Another command may currently be
executing.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?4A
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Time out for movement of the TY-axis" (QP2)
Used by: QP242,QP201,QP202,QP203,QP203
Cause: The TY-axis was not positioned within the time limit. ? is the module number. "****" is the error
code.
Remedy: Check that nothing is interfering with the movement of the TY-axis. Also, check there are no
alarms being issued from the control box of the MTU.
------------------------------
Code: 1207E?4B
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Time out for movement of the TZ-axis" (QP2)
Used by: QP242,QP201,QP202,QP203,QP203
Cause: The TZ-axis was not positioned within the time limit. ? is the module number. "****" is the error
code.
Remedy: Check that nothing is interfering with the movement of the TZ-axis. Also, check there are no
alarms being issued from the control box of the MTU.
------------------------------
Code: 1207E?4C
Display: "ICM (PMC?, SCU?) Error Code:********" (QP2)
"MFU/MTU connection error" (QP2)
Used by: QP242
Cause: The MFU/MTU is not connected to the machine. ? is the module number. "****" is the error
code.
Remedy: Connect the MFU/MTU to the machine.
------------------------------
Code: 1207E?4D
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"TZ-axis interlock alarm" (QP2)
Used by: QP242
Cause: The TZ-axis is interlocked. ? is the module number. "****" is the error code.
Remedy: Move the TZ-axis out of interlock using inching.
------------------------------
Code: 1207E?4E
第 827 页
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux-Valve operation" (QP2)
"time out" (QP2)
Used by: QP242
Cause: The operation of the flux application/supply changeover valve was not completed in the time
allowed.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that there is nothing obstructing the operation of the flux valve. Since this valve is
controlled by an air cylinder, check that air is being supplied to the cylinder and also check that the speed
controller is set correctly.
------------------------------
Code: 1207E?4F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"SCU Error : Flux Controller" (QP2)
Used by: QP242
Cause: The wrong command has been sent to the flux controller.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Restart after clearing the error.
------------------------------
Code: 1207E?50
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux Controller" (QP2)
"communication time out" (QP2)
Used by: QP242
Cause: A command has been sent to the flux controller but no response has been received.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Verify the following items.
(1) Nothing is abnormal with the cable running between the flux controller and the SCU.
(2) The connector for the flux controller communication port specified in Proper data is properly
connected.
(3) The flux controller has been booted up normally.
(4) The baud rate specified for the flux controller matches the SCU baud rate specified in Proper data.
------------------------------
Code: 1207E?51
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux Cntlr communication" (QP2)
"retry reached preset number" (QP2)
Used by: QP242
Cause: A command has been sent to me flux controller but a valid response has not been received.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Verify the following items.
(1) Nothing is abnormal with the cable running between the flux controller and the SCU.
(2) The connector for the flux controller communication port specified in Proper data is properly
connected.
(3) The flux controller has been booted up normally.
(4) The baud rate specified for the flux controller matches the SCU baud rate specified in Proper data.
------------------------------
Code: 1207E?52
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"FC-axis start time out" (QP2)
Used by: QP242
第 828 页