------------------------------ Code: 15021005 Display: Loader ROM Error. Used by: Cause: The software version in the board loader PLC ROM is newer than the software version in the machine ROM. An error results when the P…
Used by: CP643,CP643M
Cause: Main conveyor movement for the conveyance of board(s) was terminated because the out-carrier
is out of position.
Remedy: If the out-carrier is at its extended position, check the extended and unclamping limit sensors.If
the extended and unclamping limit sensors are on, the carrier may be moving too fast and has recoiled out
of position.If the carrier is not at its extended position the movement of the carrier itself may require
adjustment.
------------------------------
Code: 15010D08
Display: Board-clamper error:O_CRRY
The clamp confirmation sensor on the OUT-carrier forward limit is unstable.
Used by: CP643,CP643M
Cause: The clamp sensor operation is unstable at the out-carrier's advance limit side.
Remedy: Check the clamp sensor operation, and verify that the conveyor width is suitable for the panel in
question.
------------------------------
Code: 15021000
Display: Remove Board from Main Cvyr
Used by: IP3
Cause: Either there was a main conveyor board check sensor alarm or the sensor is not correctly
adjusted. The board was moved by hand.
Remedy: If the board has been produced, unload it. If not, put the board back into the in conveyor.
------------------------------
Code: 15021001
Display: Not defined.
Used by:
Cause: Operation was cancelled because of an alarm from the application.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs frequently,
contact Fuji.
------------------------------
Code: 15021002
Display: Not defined.
Used by:
Cause: Loading position alarm.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs often contact
Fuji.
------------------------------
Code: 15021003
Display: Not defined.
Used by:
Cause: Lifter position error.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs often contact
Fuji.
------------------------------
Code: 15021004
Display: Interlock on(cp6)
Interlock Board transfer check(gsp5)
Used by: GSP5,GP551,GP6,IP3
Cause: The machine attempted to clamp the table while the board detect sensor on either the in or out-
conveyor was on.
Remedy: Remove the board.
第 1102 页
------------------------------
Code: 15021005
Display: Loader ROM Error.
Used by:
Cause: The software version in the board loader PLC ROM is newer than the software version in the
machine ROM. An error results when the PLC version is higher than the machine version.
Remedy: Contact Fuji.
------------------------------
Code: 15021006
Display: not in loading pos.
Used by: GSP5,GP2,GP551,GP3,GP6
Cause: The table was not in loading position when the lock/unlock function was attempted in order to
perform conveyor width adjustment.
Remedy: Perform the load position command to move the table to the loading position.
------------------------------
Code: 15021007
Display: Board pstn alarm main cnvyr
Used by: GSP5,GP551,GP6
Cause: The main conveyor board check is unclear, so the results of the check are that there is a board on
the main conveyor.
Remedy: Unload this board to the out conveyor.
------------------------------
Code: 15021008
Display: unrecognizable command
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: Either there is no Proper data measurement or zero setting was not performed.
Remedy: If there is no Proper data, transmit Proper to the machine. Then, perform zero setting.
------------------------------
Code: 15021009
Display: interlock
Used by: GSP5,GP551,GP6
Cause: The width adjustment clutch has not been released so the table cannot be moved.
Remedy: Remove the clutch using the loader unlock command. If the problem recurs, adjust the clutch
retract limit sensor.
------------------------------
Code: 1502100B
Display: Idle operation error!
Used by: NP2,QP3
Cause: The loader contains a PCB, even though the machine is in idle operation.
Remedy: Remove the PCB from the loader.
------------------------------
Code: 15024001
Display: Cycle alarm servo ??
Used by:
Cause: The servo did not reach its target position within the preset time limit.
Remedy: Check that there is no load on the servo axis.
------------------------------
Code: 15024002
Display: Cycle aiarm ??
Used by:
Cause: The cylinder did not reach its target position within the preset time limit.
第 1103 页
Remedy: Check that there is no load on the cylinder. Also check the sensor signal at the I/O map.
------------------------------
Code: 15024003
Display: (Differs according to the machine.)
Failed to arrive at target position.(NP2,QP3)
Used by:
Cause: Board delivery time up error.
The specified time for the monitoring of the clearance of the PCB request signal has
elapsed.(NP2,QP3)
Remedy: The board stalled on the conveyor. Remove the board from the conveyor or re-load the board.
------------------------------
Code: 15024004
Display: (Differs according to the machine.)
Used by:
Cause: The lifter did not reach its target position within the preset time limit.
Remedy: The lifter is not working. At the I/O map check the lifter operation and the sensor input.
------------------------------
Code: 15024005
Display: (Differs according to the machine.)
Used by:
Cause: The sequencer did not reply within the preset time.
Remedy: There is no reply from the loader's sequencer. Switch off the machine and then re-boot it. If the
problem recurs it is probably due to a wiring fault or damage to the sequencer.
------------------------------
Code: 15024006
Display: (Differs according to the machine.)
Used by:
Cause: The reference pin did not reach its target position within the preset time limit.
Remedy: The reference pin is not moving. At the I/O map check the reference pin and the sensor input.
------------------------------
Code: 15024007
Display: (Differs according to the machine.)
Used by: IP3
Cause: Vertical movement of the 2 level conveyor could not be completed within the preset time limit.
Remedy: The 2 level conveyor could not move up or down within the set time. Check that it is possible for
the 2 level conveyor to freely move up and down.
------------------------------
Code: 15024008
Display: Cycle alarm (cylinder) conveyor adj. clutch
Used by: GSP5,GP551,GP6
Cause: The clutch could not enter the conveyor connecting notch within the preset time limit.
Remedy: Check for items that may be interfering with clutch movement. Check the widths of the main
and out conveyors to make sure they match. Check the sensors at the I/O board.
------------------------------
Code: 15024009
Display: Cycle alarm (cylinder) backup pin
Used by: GSP5,GP551,GP6
Cause: The backup pin could not lock or unlock within the preset time limit.
Remedy: Check the sensors at the I/O board.
------------------------------
Code: 1502400A